You are on page 1of 1

PORT

EX LOOP 2A EX LOOP 1A
70 70 70 AB 70 BM 70 70 70
BE BM BS AH BM
116.02 116.002 116.02 116.02 116.003 116.02 70-BS-117-03203 70-BM-119-01102
116.02 70-F-NIS-AJB-8751
225 121 HW 224 223 HW 202
(SHEET 3/4) (SHEET 1/4)
NOTE 9
AFT FWD
BRANCH OFF EX LOOP 1A
EX LOOP 2A 70-BS-117-03104 LOOP 1A
DN
70-BSH-117-01201 (SHEET 3/4) 70-BS-115-03128
VL
UP (SHEET 1/4) (SHEET 3/4)
STARBOARD LOOP 2A
NOTE 9
70-BS-115-03229 70 BE
DN (SHEET 3/4) 116.02
70 BE 70
BE 127
70
BE 116.02 116.02
201 228
116.02
122 MFA MFA

70
BE
116.02
226 70 BE

FA 116 116.02
103
70 AH
70 BE
116.001
116.02 HW
123
SYMBOL QTY CODE DESCRIPTION MODEL NO.
70 BM HOLD 79-S-NIS-DJB-8712
DN
116.02
124 MFA 70 - AA
AH
70 BE 116.002
HW 2 AB
116.02
125 MFA
70 BS LOOP 2A
70 BE 70 BE 3 AH
116.02
120 116.02 70-BSH-117-01211
116.02
227 212
(SHEET 1/4) - AL
70 BE
70 BE
116.02 (EARLY WARNING),
116.02 222 25 BE
126 MIN IP56
70 BE 70 BE (EARLY WARNING),
2 BE
MIN IP56, EX CERT., IIC T4
116.02 116.02
113 119

70 BE 70 - BF SHARP EYE 40/40I


BE
116.02 116.02
213 MFA 221 MFA
5 BM
70 BE 70-F-NIS-AJB-8752
116.02 MFA 1 BM
641 x 2 00
700 x 45

641x200

214 70-F-NIS-AJB-8753

70 BE 3 BS
641 x 200

641 x20 0
700 x 45

116.02
114 70
BM -
641 x 200
700 x 4 5

641 x20 0

BSH
116.02
70 BE 118
641 x 200
70 0 x 4 5

641 x20 0

116.02 - BS
215 70 BE
641 x 200

MFA 116.02
70 117 - DR
BE FA 116
641x200

116.02
115 70
BE - ES
116.02
70 BE 219
116.02 4 -
216 70 BS LOOP 1A
VL 116.02 70 BE
70 BE 70 70 BM 70 220 116.02 70-BSH-119-01111
AB BE
UP 116.02 116.001 116.02 116.02 112
116 218 217 (SHEET 1/4)
HW
VL
VL 70 70
BS AB
IMPORTANT NOTE: XXX.XX XXX.XX
XX HW
THE LOOP CABLE SHALL NOT ENTER AND EXIT FROM THE
SAME LOCATION AND SHALL NOT PASS THROUGH A
LOCATION TWICE.

MOUNTING ELEVATIONS/DIMENSIONS
AFT UTILITY & CONTROL MODULE (2 ND DECK) FA 116
CWP NO: CWP-00GN-I01

DESCRIPTION ABOVE DECK ELEVATION EL. 29800 ABL CLIENT :

Golar LNG
18002-KEP-070-I-XI-0001 FIRE & GAS BLOCK DIAGRAM FOR ADDRESSABLE LOOPS

1300mm (FOR MACHINERY ROOMS) AND 300mm (FOR 09Z 01.12.2023 DP ABM HW AS BUILT 18002-KEP-070-I-XE-0002 FLNG FIRE & GAS DETECTION AREAS OVERALL VIEW

SMOKE/HEAT DETECTORS LER & IER) FROM CEILING OR DIRECT TO FALSE 08 12.08.2022 NG ABM HW APPROVED FOR CONSTRUCTION 18002-KEP-070-I-XE-0003 F&G SYSTEM LAYOUTS FOR SPONSON DRAWN : MRN TITLE : CLIENT DWG NO. :
CEILING (MAX. 5500mm FROM BULKHEAD/WALL) 07 22.01.2021 NG ABM HW APPROVED FOR CONSTRUCTION 18002-KEP-070-I-XE-0004 FIRE & GAS LAYOUT FOR BOW MACHINERY SPACE & HVAC AIR INLET / AIR LOCKS DATE : 22.01.2021
FIRE & GAS LAYOUT
06 31.08.2020 NG ABM HW APPROVED FOR CONSTRUCTION 18002-KEP-070-I-XE-0005 FIRE & GAS LAYOUT FOR CARGO CONTAINMENT AREAS
SCALE : NTS 18002-KEP-070-I-XE-0008
MANUAL FIRE ALARMS AND FOR NEW AFT MODULE
1400mm TO 1500mm 05 25.06.2020 NG ABM HW APPROVED FOR CONSTRUCTION 18002-KEP-070-I-XE-0007 FIRE & GAS LAYOUT FOR ACCOMODATION & ENGINE ROOM
CHKD : NG SHEET 02 OF 05
PUSH BUTTONS 04 23.01.2020 NG ABM HW ISSUED FOR CONSTRUCTION 18002-KEP-070-I-XE-0006 FIRE & GAS LAYOUT FOR OFFLOADING AREA
MAIN CODE : SS01G/00004 REV. NO. : 09Z
POINT HC GAS DETECTORS MTD ON/IN DUCT 03 16.12.2019 NG ABM HW REISSUED FOR APPROVAL 18002-KEP-070-I-XI-0002 FIRE & GAS DETECTION SYSTEM TOPOLOGY
This document is the property of VESSEL :
Shipyard
02 22.08.2019 NG ABM HW REISSUED FOR APPROVAL 18002-KEP-070-I-LA-0001 FIRE & GAS INDEX & IO LIST
Keppel Shipyard. It is not to be
FLNG STATUS LIGHTS 1800mm - 2400mm NO. DATE BY CHKD. APPD. DWG. NO. copied nor shown to a third party GOLAR GIMI FLNG
REVISIONS REFERENCE DRAWINGS

You might also like