Subject: Test results of shear wall components b-panel PT. Beton Elemenindo Putra

I. Introduction
1.1 Types / number of samples : Test object is a component of shear wall structure Rigid full wall panels
(without openings) is mounted on a concrete cradle (parallel to the
direction of lateral loading), 2 object test
1.2 Dimensional test object : 2444 mm x 115 mm x 3005 mm
1.3 Concrete mounting dimensions : 2700 mm x 595 mm x 305 mm
1.4 Type of test : Pseudo lateral load test of dynamic back and forth
1.5 Test date : 25th Januari 2008 (test object 1)
1st Februari 2008 (test object 2)

II. Test Results :

Lateral load Melt Test objek 1 Test objek 2

Melt Vy(+) = 52,90kN, δy(+) = 2,02 mm Vy(+) = 123.50kN, δy (+) = 3.78 mm


Maximum Vmax(+) = 84,30kN, δmax(+) = 5,6 mm Vmax(+) = 143,40kN, δmax(+) = 5,62 mm
1 Fush
When story drift
V(+) = 67,30 kN, δ (+) = 7,06 mm V(+) = 121 kN, δ (+) = 7 mm
0.250% cycle 3
Melt Vy(-) = 62,70kN, δy(-) = 1,98 mm Vy(-) = 131,40kN, δy(-) = 2,82 mm
Maximum Vmax(-) = 97,60kN, δmax(-) = 5,64 mm Vmax(-) = 157kN, δmax(-) = 6,08 mm
2 Tensile
When story drift
V(-) = 82,50 kN,, δ (-) = 7,18mm V(-) = 128,60 kN, δ (-) = 7,04mm
0.250% cycle 3

All the test results data, curves and crack patterns due to the load can be seen in appendix

Note: The data is valid only up to 0.25% drift, this is because the next cycle is affected by the upward
movement of the end walls, suspended by a hydraulic vertical jack so that load would increase again.

Signed by: Ir Lutfi Faizal


Head Of Structure & Building Construction Testing Center