Specifications Connections
ROTARY ENCODER(INCREMENTAL TYPE) Item Side-mounting shaft type of incremental rotary encoder Wheel type of incremental rotary encoder
◎ENA Series
Cable
ENA/ENC SERIES Totem pole output ENA- - -T- ENC-1- -T- - Black: OUT A Pin No. Function
White: OUT B color
Model NPN open collector output ENA- - -N- ENC-1- -N- - 1 Black OUT A
Orange: OUT Z
Voltage output ENA- - -V- ENC-1- -V- -
INSTRUCTION MANUAL *1, *2, *5, 10, 12, 15, 20, 23, 25, 30, 35, 40, 45, 50, 60, 75, 100, 120, 125, 150, 192,
Brown: +V(5VDC, 12-24VDC ±5%)
Blue: GND(0V)
2
3
White
Brown
OUT B
+V
Resolution(PPR)※1 200, 240, 250, 256, 300, 360, 400, 500, 512, 600, 800, 1000, 1024, 1200, 1500, 1800, 1mm/Pulse, 1cm/Pulse, 1m/Pulse, 0.01yd/Pulse, 0.1yd/Pulse, 1yd/Pulse Shield: F.G. 4 Blue GND
2000, 2048, 2500, 3000, 3600, 5000
1 Black OUT A
ENA- -2- - : A, B phase 2 White OUT B
Output phase A, B phase ※In case of ENA- -3- - model, Z phase is output.
ENA- -3- - : A, B, Z phase 3 Orange OUT Z
※Unused wires must be insulated.
T T ※The metal case and shield cable of encoder should 4 Brown +V
Phase difference of output Output between A and B phase: ± (T= 1cycle of A phase)
4 8 be grounded(F.G.). 5 Blue GND
ENA ENC Totem pole
● [Low] - Load current: Max. 30mA, Residual voltage: Max. 0.4VDCᜡ ※Do not apply tensile strength over 30N to the cable.
● [High] - Load current: Max. 10mA, Output voltage(Power voltage 5VDCᜡ): Min.(Power voltage-2.0)VDCᜡ,
output
Output voltage(Power voltage 12-24VDCᜡ): Min. (Power voltage-3.0)VDCᜡ
Control ◎ENC Series
Thank you for choosing our Autonics product. output NPN open
Load current: Max. 30mA, Residual voltage: Max. 0.4VDCᜡ ●Axial cable type ●Axial cable connector type
collector output
Please read the following safety considerations before use.
Voltage output Load current: Max. 10mA, Residual voltage: Max. 0.4VDCᜡ Black: OUT A Cable
White: OUT B Pin No. Function
Totem pole color
Safety Considerations Electrical Response
output Orange: N.C.(Not connected)
Brown: +V(5VDC, 12-24VDC ±5%)
1 Black OUT A
specification time NPN open Max. 1㎲ (Cable length:2m, I sink = 20mA)
※Please observe all safety considerations for safe and proper product operation to avoid (rise/fall) collector output ENC Blue: GND(0V) 2 White OUT B
hazards. Shield: F.G. 3 Orange N.C.
Voltage output CCW
※ symbol represents caution due to special circumstances in which hazards may occur. Max. Response frequency 300kHz 180kHz 4 Brown +V
※Unused wires must be insulated.
Warning Failure to follow these instructions may result in serious injury or death. Power supply ●5VDCᜡ ±5%(Ripple P-P: Max. 5%) ●12-24VDCᜡ ±5%(Ripple P-P: Max. 5%) 5 Blue GND
※The metal case and shield cable of encoder should
Caution Failure to follow these instructions may result in personal injury or product damage. Current consumption Max. 80mA(disconnection of the load) 6 Shield F.G.
be grounded(F.G.).
Insulation resistance Min. 100MΩ(at 500VDC megger between all terminals and case) ※Do not apply tensile strength over 30N to the cable. ※F.G.(Field Ground)
Warning Dielectric strength 750VAC 50/60Hz for 1 minute(Between all termials and case) : It should be grounded separately.
1. Fail-safe device must be installed when using the unit with machinery that may cause Connection Radial connector type Axial cable type, Axial cable connector type
serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment,
ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster Starting torque Max. 70gf.cm(0.007N.m) Dependent on the coefficient of friction
prevention devices, etc.)
Failure to follow this instruction may result in fire, personal injury, or economic loss. Mechanical
Moment of inertia Max. 80g.cm2(8×10-6kg.m2)
- Output Waveforms
specification Shaft loading Radial: 10kgf, Thrust: 2.5kgf
2. Install on a device panel to use. ◎ENA Series ◎ENC Series
Failure to follow this instruction may result in fire. Max. allowable revolution ※2
5000rpm CW
3. Do not connect, repair, or inspect the unit while connected to a power source. ● Totem pole output / ● Totem pole output /
Failure to follow this instruction may result in fire. Vibration 1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each X, Y, Z direction for 2 hours NPN open collector output / NPN open collector output /
4. Check 'Connections' before wiring. Shock Approx. Max. 75G Voltage output Voltage output
Failure to follow this instruction may result in fire. CCW
5. Do not disassemble or modify the unit. Ambient temperature -10 to 70℃, Storage: -25 to 85℃
Environment T
Failure to follow this instruction may result in fire. Ambient humidity 35 to 85%RH, Storage: 35 to 90%RH
Caution Protection structure IP50(IEC Standards) T
±
T T
●ENA- -2- - , ENC: Ø5mm, 4-wire, Length: 2m, Shield cable (AWG 24, Core wire diameter: 0.08mm, Number of cores: 40, Insulator out diameter: Ø1mm) 2 4
1. Use the unit within the rated specifications. T T
Cable ±
Failure to follow this instruction may result in fire or product damage. ●ENA- -3- - : Ø5mm, 5-wire, Length: 2m, Shield cable (AWG 24, Core wire diameter: 0.08mm, Number of cores: 40, Insulator out diameter: Ø1mm) H 2 4
2. Do not short the load. A phase
Accessory Ø10mm coupling, Connector cable - L T T H
Failure to follow this instruction may result in product damage by fire. ± A phase
Approval 4 8 L
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, T T
±
direct sunlight, radiant heat, vibration, impact, or salinity may be present. Unit weight Approx. 345g Approx. 494g H 4 8
Failure to follow this instruction may result in fire or explosion. B phase
※1: '*' pulse is only for A, B phase. ※Environment resistance is rated at no freezing or condensation. L B phase H
4. Do not use the unit near the place where there is the equipment which generates strong
magnetic force or high frequency noise and strong alkaline, strong acidic exists. ※2: Make sure that Max. response revolution should be lower than or equal to max. allowable revolution when selecting the resolution. H L
Failure to follow this instruction may result in product damage. Z phase T CCW
Max. response frequency L
[Max. response revolution(rpm) = × 60 sec] T±
Resolution 2
Ordering Information CW
ENA - 5000 - 2 - N - 24 Dimensions ※In case of ENA- -3- - model, Z phase is output.
(unit: mm) (unit: mm)
Series Pulses/Revolution Output phase Control output Power supply ◎ENA Series 4 holes connector(※) ◎ENC Series 84
Side-mounting shaft type T: Totem Pole output Connector (SCN-16-4-wire) 78
2: A, B 5: 5VDC ±5%
(external diameter of See resolution N: NPN open collector output 55.5
3: A, B, Z 24: 12-24VDC ±5% 55.5
shaft: Ø10mm) V: Voltage output 2-Ø5.5
ENC - 1 - 1 - N - 24 - 9.4 20 Caution during Use
Wheel circumference
1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected
Series Output phase Min. measuring unit Control output Power supply Cable
-0.005
Ø10-0.01
accidents.
Ø26
82
Ø50
70.5
24
35
1: 1mm 4: 0.01yd
97
70
Wheel N: NPN open 5: 5VDC ±5% : Axial cable type 2. 5VDC, 12-24VDC power supply should be insulated and limited voltage/current or Class 2,
1: A, B 2: 1cm 5: 0.1yd
type collector output 24: 12-24VDC ±5% C: Axial cable SELV power supply device.
40
3: 1m 6: 1yd ENC
V: Voltage output connector type(※) 3. For using the unit with the equipment which generates noise (switching regulator, inverter,
31
5
※Cable length: 250mm 84 servo motor, etc.), ground the shield wire to the F.G. terminal.
56
70 4. Ground the shield wire to the F.G. terminal.
Control Output Diagram 101 Wheel
circumference
The number of
encorder pulse
Gear
ratio
Min. measuring
unit
Cable for axial
cable type
Cable for axial cable
connector type 5. When using switching mode power supply, frame ground (F.G.) terminal of power supply
Rotary encoder circuit Load connection ※ENA- -3- - 250mm 250 Pulse 1:1 1mm/1 Pulse Ø5, 4-wire, should be grounded.
48 : 5 holes connector (SCN-16-5P) 250mm 100 Pulse 4:1 1cm/1 Pulse Ø5, 4-wire, Length:
+V ◎Coupling Length: 2000mm,
250mm, Shield cable 6. Wire as short as possible and keep away from high voltage lines or power lines,
250mm 1 Pulse 4:1 1m/1 Pulse Shield cable
Sink current ※1 ●ENA Series to prevent inductive noise.
: Max. 30mA 228.6mm(0.25yd) 100 Pulse 4:1 0.01yd/1 Pulse
Totem pole Load Ø22 7. Check the wire type and response frequency when extending wire because of distortion of
Main circuit
Source current
Parallel misalignment: Max. 0.25mm 8. This unit may be used in the following environments.
: Max. 10mA Load
0V Angular misalignment: Max. 5° ◎Connector cable (Socket type) (Sold separately) ①Indoors (in the environment condition rated in 'Specifications')
20