You are on page 1of 1

CAST IRON FRAME & COVER

o
GROUND LEVEL GROUND LEVEL 45 TUMBLING BAY JUNCTION

MAX.450

MAX.450
600 600

675 675

750 750
225mm ENGINEERING BRICKWORK

ES

ES
VARI

VARI
GRADE 25 CONCRETE BENCHING TO BE FILLED WITH
DETAILS OF MULTISTRAND

1500m m
500m m
50mm FILLET
POLY-PROPYLENE NYLON CONCRETE GRADE 25
ROPE NETTING REFER TO
( DWG NO. PUB/WRN/STD/008 )

300

MUM
MUM
0
90 BACKDROP JUNCTION

MAXI
NI
MI
15
0
80 80mm CHAMFER

E
IP
450

P
P
U
-
E
K
1 500 OR (D 300)mm

A
C

M
(WHICHEVER IS THE GREATER)

D
2
1800 OR 1.5D
2000

2000
(WHICHEVER IS THE GREATER)

150mm THK. GRADE 25 0

CONCRETE SURROUND 45 TUMBLING BAY


GRADE 25 CONCRETE BENCHING
25mm THICK SOFT BREAK JOINTS TO BE PROVIDED
(WHERE REQUIRED)
BOARD (CELOTEX) AT PIPE JOINTS NOT GREATER

1 500m m
OR OTHER APPROVED THAN 6m INTERVALS AND AT (MAX. 450mm DIA.)
STAINLESS STEEL SAFETY
MATERIAL THE 1st & 2nd PIPE JOINT
CHAIN OR MULTI - STRAND
NEXT TO MANHOLE
POLY-PROPYLENE NYLON
ROPE

NMUM
MI
D’
’AMETER

75
100
DI

GRADE 25 CONCRETE BENCHING


D
150

90 BACKDROP
D
150mm THICK GRADE (WHERE REQUIRED)
150mm THICK GRADE 25
25 CONCRETE SURROUND (MAX. 450mm DIA.)
CONCRETE SURROUND

SECTION A-A PILES AND FOUNDATION TO ENGINEER’S DETAILS


SECTION B-B

B
o
1350 X 1350
45 BEND
STRAIGHT-IN CONNECTION
750 X 750

(WHERE REQUIRED)

DETAILS OF MULTISTRAND
POLY-PROPYLENE NYLON
ROPE NETTING REFER TO
A ( DWG NO. PUB/WRN/STD/008 )
STAINLESS STEEL PLATE
75 SQ. X 10 GAUGE THK. &
16 mm DIA. STAINLESS
D

NUT
X STEEL EYE
OW
FL
75 50mm INT. DIA. STAINLESS STEEL 65
DRILL ANCHOR OR
RINGS OR 16 mm DIA. MULTI-STRAND 10mm STAINLESS
SIMILAR FIXING
POLY-PROPYLENE NYLON ROPE

75
STEEL D SHACKLE
THE GREATER)
2D

1.5D)

300

Y Y
2700 OR (900

THREAD TO EXTEND
N.75m m

25mm BEYOND NUT


I
300

300

CHEVER

300
SHORT PIPE
MI

SHORT PIPE
(W HI

ELEVATION Y - Y PLAN X - X

DETAIL OF SAFETY CHAIN

SCALE 1 : 10

BACKDROP 2400 OR (D 1 200)

(WHICHEVER IS THE GREATER)

NOTES.
1. UNLESS OTHERWISE STATED, ALL CONCRETE MIX TO BE GRADE 25 AND ABOVE.

PLAN C-C ROOF SLAB 2. BENCHING TO BE IN GRADE 25 CONCRETE.


B
3. ALL STEEL REINFORCING BARS TO HAVE MIN. 50mm.

4. PIPES SHOULD END 75mm SHORT OF MANHOLE INTERNAL WALL.

5. MANHOLES EXCEEDING 6.0m DEEP TO INVERT, SHALL BE DESIGNED SEPARATELY.

SCALES

ISSUED BY WATER RECLAMATION (NETWORK) DEPARTMENT 1 : 20


0
ON OCT ’09 UNLESS STANDARD 45 BEND MANHOLE FOR SEWERS 1050mm DIA. AND ABOVE Water for All:Conserve,Value,Enjoy

OTHERWISE
WATER RECLAMATION (NETWORK) DEPARTMENT
STATED DRG. NO. PUB/WRN/STD/004A