You are on page 1of 1

Cast Iron Medium duty cover and frame for Cast Iron Medium duty cover and frame

um duty cover and frame for Cast Iron Medium duty cover and frame for
clear 600 x 450 opening and bedded into clear 600 x 450 opening and bedded into NO. OF
clear 750 x 600 opening and bedded into INTERNAL DIMENSIONS CAPACITY
cement mortar cement mortar cement mortar USERS
Ground Level L1 L2 H1 H2 B Cu. M
Inlet pipe
100mm dia. outlet pipe 1540mm 760mm 1600mm 1750mm 760mm 3.2 10 FINISHES SCHEDULE
150mm dia. C.I dip pipe Dressed timber scumboard to drainage soak pit/ LEVEL
FLOOR WALL CEILING
Notes:-

450
ex. 35mm thick percolation trenches 1900mm 900mm 1800mm 2000mm 900mm 4.5 20 DESCRIPTION SKIRTING
150

150
Top Water Level

50
2000mm 1000mm 1800mm 2100mm 1100mm 5.9 30 Silk vinyl paint to cement Ground & first
150 1. All dimensions to be checked on site, written

200
Living room / Non slip porcelain floor plastered slab soffit floor level

375
100mm high matching Silk vinyl paint dimensions to be followed in preference to scaled

60
2400mm 1100mm 1800mm 2100mm 1150mm 7.24 Dining

500
40 tiles of approved sample floor tiles of approved sample Silk vinyl paint to cement Second floor
level dimensions.
2500mm 1200mm 1300mm 8.6 plaster on expanded metal lathe
1800mm 2100mm 50
1:3 Cement/sand 1:3 Cement/sand Weather guard paint to cement Ground & first
45 deg.. fillet 2100mm plastered slab soffit floor level 2. All walls less than 200mm thick to be reinforced with
45 deg. fillet 2700mm 1300mm 1800mm 1400mm 10 60 Non slip ceramic floor tiles 100mm high matching Glazed wall tiles & brilliant
Kitchen hoop iron at every alternate course.
of approved sample floor tiles weather guard emulsion paint Weather guard paint to cement Second floor
250 x 240mm Beam 250 x 400mm Beam 250 x 400mm Beam
29000mm 1400mm 1800mm 2100mm 1450mm 11.3 70 plaster on expanded metal lathe level
Ground & first 3. All reinforced concrete work is to be in accordance
1800mm Silk vinyl paint to cement
3000mm 1500mm 2100mm 1560mm 12.7 with structural engineer's details.

H2

H1
80 Non slip ceramic floor tiles 100mm high matching plastered slab soffit floor level
Bedrooms Silk vinyl paint
1600mm of approved sample floor tiles of approved sample Silk vinyl paint to cement Second floor

800
3200mm 1800mm 2100mm 1600mm 14 90
plaster on expanded metal lathe level 4. All sanitary work to be in accordance with M.O.H rules
and regulations.
3300mm 1700mm 1800mm 2100mm 1700mm 15.4 100 Weather guard paint to cement Ground & first
Non slip ceramic floor tiles 100mm high matching Glazed wall tiles & brilliant plastered slab soffit floor level
4000mm 2200mm 1800mm 2100mm 2190mm 24 Bathrooms floor tiles weather guard emulsion paint 5. Where drain passes under building or driveway
150 of approved sample Weather guard paint to cement Second floor
level
area,pipe to be of cast iron or encased in 150mm
plaster on expanded metal lathe
4500mm 2700mm 1800mm 2100mm 2650mm 34.3 200 concrete.
50mm blinding weather guard paint to cement Ground & first
Stair case / weather guard paint plastered slab soffit floor level
68.6 Granite floor finish 100mm high matching 6. All waste pipes and soil pipes are to be in ducts and
SECTION A - A 100mm dia. outlet pipe 5500 3700mm 1800mm 2100mm 3750 400 Lobby floor tiles of approved sample Silk vinyl paint to cement Second floor
plaster on expanded metal lathe the bends to have all cleaning eyes accessible from
Concrete benching returned to drainage soak pit/ level
outside.
at soffit height of pipe at percolation trenches Weather guard paint to cement Ground & first
1:12 slope Water proof rendering in Non slip ceramic floor tiles 100mm high matching Weather guard paint plastered slab soffit floor level
two 10mm layers each Balcony 7. All windows and external glazed doors on ground floor
of approved sample floor tiles of approved sample Weather guard paint to cement Second floor
layer brashed with vandex to have burglar proofing to Architect's detail.

190
plaster on expanded metal lathe level
Inlet pipe
120

20 Weather guard paint to cement Ground & first


Non slip ceramic floor tiles Weather guard paint floor level 8. All door frames to be rebated & moulded & be full
100mm high matching plastered slab soffit

50
Verrandah width of wall with moulded architrave to detail, provide

20
of approved sample floor tiles of approved sample Weather guard paint to cement Second floor
rubber door stops to all doors.

750
600

plaster on expanded metal lathe level

9. Stair case and lobby doors to be self closing and 1/2


120

190
hour fire resistant.

250 x 400 mm INTERNAL WATER PROOF TO 10. All internal plaster to be two coats steel float finished.
Beam WALLS AND SLABS
11. All manholes within building area, driveway and
ROOF SLAB PLAN parking to have heavy duty air tight covers and double
sealed.

30

40
B C 12. Provide G.I. 125 x 100 rainwater down pipes and125 x
240 L1 240 L2 240
250mm RC Slab 100 G.I.box gutter with brackets etc. where shown.
40x30x3mm th. x 650mm long E D C B A
Brollo channel bolted to wall
with 3No. 12mm dia. bolts 13. All painting to be 3 coats.
50mm blinding
240

14. Splash apron of 1000mm along the perimeter of


SECTION C - C building.

650
A A 15. Samples of fittings, materials etc. to be produced &
40x80x4mm th. x 40mm wide approved before commencing work.
Brollo angle bolted to wall
with 2No. 12mm dia. rawbolts 16. All windows to have P.C. cills, built in reinforced
B

80
concrete Pelmet boxes & timber internal window cills &
Skirtings.
FIXING DETAIL OF SCUMBOARD
17. Steel trusses/portal frames & purlins to be painted
(GALVANISED )
with 2 coats of oil paint.
240

75 75
18. Fire fighting equipment to be provided and installed
B C by Building Fire Consultants where shown on plan.

175 50
BASE SLAB PLAN 19.These architectural drawings shall be read in
conjunction with the Structural drawings,Electrical-
Mechanical drawings, Bills of Quantities & Technical
Specifications. Any discrepancy shall be reported
CONC. WEIR BLOCK DETAIL immediately to the Architect.
A
Selected filling well compacted and
consolidated. 20. The Architect shall not accept any liability for works
25mm dia m.s. vertical railing
1,200 1,175

which he has not been expressly instructed to Supervise


at 150mm c/c on both sides 50mm blinding
in writing and has accepted to proceed in writing, or
E D C B A for any ommissions or deviations from his
SECTION B - B 3,230 1,730 4,430 4,665 drawings/technical specifications.
2,575

Nor shall he take responsibility for works handled by


pointed cement blocks other nominated Consultants or Contractors.
Inlet pipe
3000 min

1:100 Front Elevation 1:100 West Elevation


Tyrolean render

Selected stone Client:


profile.
3,500 3,500 MISS NASSAMULA MARGARET
200

Tel: 0702 985932


ELEVATION (Roadside)
Email: MNassamula@bou.or.ug
scale 1:50
SECTION THRU SOAK PIT Address
: P.O BOX 7120, Kampala- Uganda
500x75mm precast
A coping to columns

25mm dia m.s. vertical railing


3 2 1 Architect:
700

at 150mm c/c on both sides


25mm dia m.s. vertical railing A B C D E
at 150mm c/c on both sides
25x50mm horizontal m.s.
bars anchored to wall
2,575

light fitting to specification


1,675

pointed cement blocks


75
25

225mm precast concrete


Tyrolean render coping to top of boundary wall
Project Name and Address:

3,000 3,500 PROPOSED RESIDENTIAL HOUSE ON


200

200mm block walling


ELEVATION
PLOT 1142 , BLOCK 104, KYAGGWE
scale 1:50 COUNTY, MUKONO DISTRICT

BOUNDARY WALL
1800
1775

Drawing Title:
A WORKING DRAWINGS

400x400mm blockwork
column with brick facing Job no: Drwg no:
COPING PLAN
scale 1:50

A B C D E 4,626 3,730
Scale:
REVISIONS
400 400 400 4,665 4,430 1,730 3,230 1:50
Drawn by: No: Date Descriptions
3 2 1
Checked by:
A

1:100 Rear Elevation


400

1:100 East Elevation Date:


200

MAY 2016
foundation to S.E's detail
200
400

200
400

SECTION A-A
scale 1:20
PLAN 400x400mm blockwork
200mm thick block walling
scale 1:50
with brick facing column with brick facing NOTE
All reinforcements are to Structural Engineer's details
GSPublisherEngine 0.1.100.100