CAST IRON FRAME & COVER

o
GROUND LEVEL 45 TUMBLING BAY JUNCTION

MAX.450
600

675
225mm ENGINEERING
BRICKWORK
750

DETAILS OF MULTISTRAND
POLY-PROPYLENE NYLON
ROPE NETTING REFER TO

ES
VARI
( DWG NO. PUB/WRN/STD/008 )

1500m m
500m m
GRADE 25 CONCRETE
BENCHING TO BE FILLED WITH

CONCRETE GRADE 25
50mm FILLET

MUM
MUM

MAXI
NI
15
0

MI
E
IP
P
P
U
-
E
K
A
M
80mm CHAMFER

450
MIN. 1.5mm THICK PVC
D
OR HDPE LINING
2

1800 OR (D 300)

(WHICHEVER IS THE GREATER)

0
DIA. 40mm ALUMINIUM

C ALLOY HANDRAIL
C 45 TUMBLING BAY

2000
90 BACKDROP JUNCTION (WHERE REQUIRED)

(MAX. 450mm DIA.)

(D 300) 150

N.1 500m m
1000

ES
VARI
25mm THICK SOFT

MI
BOARD ( CELOTEX )
OR OTHER APPROVED
MATERIAL
150 150

STAINLESS STEEL SAFETY


CHAIN OR MULTI- STRAND
150

POLY-PROPYLENE NYLON
ROPE

MIN. 1.5mm THICK PVC


OR HDPE LINING

D’
N.2000

‘AMETER
MI

100 75
DI

150mm THICK GRADE 25


CONCRETE SURROUND

CONCRETE GRADE 25
150

0
90 BACKDROP
150mm THICK GRADE
25 CONCRETE SURROUND (WHERE REQUIRED)
(MAX. 450mm DIA.)

BREAK JOINTS TO BE PROVIDED


PILES AND FOUNDATION TO ENGINEER’S DETAILS
AT PIPE JOINTS NOT GREATER
THAN 6m INTERVALS AND AT SECTION A-A SECTION B-B
THE 1st & 2nd PIPE JOINT STRAIGHT IN CONNECTION
NEXT TO MANHOLE

(WHERE REQUIRED)

DETAILS OF MULTISTRAND
B POLY-PROPYLENE NYLON
ROPE NETTING REFER TO
( DWG NO. PUB/WRN/STD/008 )
45 BEND BACKDROP
STAINLESS STEEL PLATE
(WHERE REQUIRED)
75 SQ. X 10 GAUGE THK. &
50mm INT. DIA.
16 mm DIA. STAINLESS NUT
STAINLESS STEEL X
STEEL EYE
RINGS OR 16mm DIA.
MULTI-STRAND POLY-
PROPYLENE NYLON ROPE DRILLANCHOR OR
SIMILAR FIXING

10mm STAINLESS
150

STEEL D SHACKLE
1350

750

50mm FILLET
750 X
1350 X
+ 1200 )

THREAD TO EXTEND
Y
25mm BEYOND NUT
FLOW
(D

ALUMINIUM ALLOY
A SAFETY CHAIN
600

ELEVATION Y-Y PLAN X-X


150

DETAIL OF SAFETY CHAIN


SCALE 1 : 10
SHORT PIPE SHORT PIPE

2700 OR (D + 1200) NOTES.


(WHICHEVER IS GREATER) 1. UNLESS OTHERWISE STATED, ALL CONCRETE MIX TO BE GRADE 25 AND ABOVE.
BACKDROP 2. BENCHING TO BE IN GRADE 25 CONCRETE.
(WHERE REQUIRED)
3. ALL STEEL REINFORCING BARS TO HAVE MIN, 50mm COVER.
ROOF SLAB 4. PIPES SHOULD END 75mm SHORT OF MANHOLE INTERNAL WALL.

5. MANHOLES EXCEEDING 6.0m DEEP TO INVERT, SHALL BE DESIGNED SEPARATELY.


B

SECTION C-C

SCALES

ISSUED BY WATER RECLAMATION (NETWORK) DEPARTMENT 1:20

ON OCT ’09 UNLESS STANDARD MANHOLE FOR SEWERS 1050mm DIA. AND ABOVE Water for All:Conserve,Value,Enjoy

OTHERWISE WATER RECLAMATION (NETWORK) DEPARTMENT


STATED
DRG. NO. PUB/WRN/STD/005A

[ ORIGINAL BORDER SIZE 810mm X 565mm ]