You are on page 1of 1

100mm S.

W DISPERSION
CONCRETE PRE CAST PIPE LAID OPEN JOINTED
100mm DIA VENTILATING PIPE 3000mm LONG
RCC SLAB ( 1:11:3 )MIX
100mm. THICK EACH
300mm WIDE 100mm DIA TEE OUTLET
100mm DIA PIPE CHAMBER COUNDRY ROOFING PAN TILES
EXTRA LARGE TO COVER THE
IN LET CHAMBER 230
SIDES PARTLY

EQ 100
G L FORMATION LEVEL

300
450

300
G L

450 250

450

AS PER TABLE
600

DEPTH (D1)
PLUGGED

150

EQ
WITH DRY

AS PER TABLE
BRICK WORK IN C.M ( 1:5 )
340 BRICK

1300
DEPTH(D)
INSIDE PLASTERED WITH
C.M(1:3) 12mm THICK. 460

EQ
150 150

300
300
BROKEN STONE 50mm SIZE SAND AT BOTTOM AND ALLROUND
P.C.C. 1:2:4 ,LAID TO 1 IN 20 SLOPE 300 300
AND PLASTERED WITH C.M . 1:3 , LENGTH (L1) - AS PER TABLE
P.C.C. 1:3:6 300mm THICK
12mm THICK .

SEPTICTANK AND DISPERSION


SECTION ON ' A - A ' SECTION ON ' B - B '

BASED ON SITE CONDITIONS


G L

DEPTH(D1) 300
COUNDRY ROOFING PAN TILES COUNDRY ROOFING PAN TILES

DISTANCE BETWEEN

AS PER TABLE
LARGE TO COVER SIDES PARTLY

TRENCH TO BE DECIDED
LARGE TO COVER SIDES PARTLY

230 EQ 230 600 230 EQ 230


OUT LET

BREATH (B) -AS PER TABLE


CHAMBER C
IN LET CHAMBER 100mm.DIA DISPERSION PIPE
BAFFLE WALL 50mm

300 BREATH(B1) 300


THICK RCC SLAB 50mm.SIZE BROKEN STONE

300
AS PER TABLE
SAND AT BOTTOM AND ALLROUND
300 300
BREATH (B1)
A A AS PER TABLE
B B

L/5 C SECTION ON ' C - C '


100mm DIA . DISPERSION
2/3 L L/3 PIPE LAID OPEN JOINTED

230 600 230 230 600 230 300 300


LENGTH (L) - AS PER TABLE LENGTH (L1) - AS PER TABLE

PLAN
PLAN DETAILS OF DISPERSION TRENCH
DETAILS OF SEPTIC TANK
TABLE SHOWING THE DIMENSION OF SEPTIC TANK
AND DISPERSION TRENCH FOR DIFFERENT POPULATION
NOTE

1) RCC COVER SLAB MAY BE EITHER CAST IN SITU WITH MAN HOLES OR PRECAST DEPENDING ON THE SIZE Sd X X X Sd X X X Sd X X X
LENGTH DISPERSION TRENCH EXECUTIVE ENGINEER SUPERINTENDING ENGINEER CHIEF ENGINEER
OF THE TANK AND SITE CONDITIONS . INCLUDING BROKEN STONE CIVIL / TRANSMISSION TRANSMISSION TRANSMISSION
SL. POPULATION BAFFLE WALL BREATH ( B ) DEPTH ( B )
(L) FILLING DIMENSIONS
2) THIS SEPTIC TANK IS DESIGNED FOR WATER FLUSHED LATRINES ONLY AND NOT FOR DOMESTIC WASHING . NO. TO BE SERVED IN METRE IN METRE
IN METRE (L1 X B1 X D1 )
3) WHERE BRICKS ARE NOT AVAILABLE OR COSTLY , RANDOM RUBBLE MASONRY SHALL BE ADOPTED .
1. 10 PERS ONS 2.00 0.90 1.70 4.00 X 0.09 X 1.30
4) THE LOCATION OF DISPERSION TRENCH SHALL NOT BE SUBJECTED TO FLOODING DURING RAINSTORMS .
2. 20 PERS ONS 2.30 1.10 1.80 5.00 X 0.90 X 1.30
SHALL BE REMOVED AT A TIME .
3. 30 PERS ONS 3.00 1.30 1.80 6.00 X 0.90 X 1.30
5) DESLUDGING SHALL BE DONE ONCE IN TWO YEARS DURING DESLUDGING ONLY PART OF THE SLUDGE TAMILNADU ELECTRICITY BOARD
4. 50 PERS ONS 4.30 1.40 1.80 6.00 X 0.90 X 1.30
SHALL BE REMOVED AT A TIME .
5. 80 PERS ONS 4.70 1.80 2.00 6.00 X 1.20 X 1.30 DRAWN BY :
6) ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE NOTED . K.VENUGOPAL DRAWING NO :
6. 100 PERS ONS 5.70 2.10 2.00 6.50 X 1.20 X 1.45 SRD .MAN TR / S / 92
7) DISPERSION TRENCH SHALL BE ATLEAST 18.0 M FROM WATER SOURCE LIKE WELL , ETC .
7. 150 PERS ONS 7.70 2.40 2.00 8.50 X 1.20 X 1.45 TYPE DESIGN
THIS DRAWING BASED ON G65C AND IS : 2470 .
8. 200 PERS ONS 8.90 2.70 2.00 10.35 X 1.20 X 1.55 CHECKED BY : FOR DATE :
30.12.2003
9) TOP OF THE VENTILATING PIPE (COWL) SHALL BE PROVIDED WITH MOSQUITO PROOF WIRE MESH .
9. 300 PERS ONS 10.70 3.30 2.00 13.70 X 1.50 X 1.55 SEPTIC TANK
APPROVED BY : SCALE

CE / TR N.T.S