You are on page 1of 1

1 2 3 4 5 6 7 8 9 10

5.02 3.90 5.00 4.10 5.00 3.90 3.90 5.10 4.65

A A
3.80

B B

Ø12mm @ 220 mm Bottom


SEC. 2-2
4.80

Ø12mm @ 150 mm Bottom


Ø12mm @ 200 mm Top

Ø12mm @ 200 mm Top


C C 2Ø25
2.70

12@250 mm
4Ø25
D D

10@250 mm
4.30

5Ø25
4-12
E E
2Ø25
3.75

B2: just basement floor


F F
B3

1 2 3 4 5 6 7 8 9 10

Ø12@200+add Ø16@200. MESH


ADDITIONAL ADDITIONAL
Ø16@150 mm Ø16@150 mm
TOP L=4m TOP L=3m

Ø12@150 B. MESH

FOR ALL W3 FOR ALL W1&W2

SLAB REINFORCEMENT (BASEMENT ) no. date initials revision

SLAB THICKNESS = 220 mm

25 mm slab camber 25 mm
colum Reinf.
MINIMUM LAP LENGTH (UNLESS NOTED ON DRAWINGS) SHOULD BE AS TABLE BELWO :- job title

Camber TOP REINFORCEMENT BAR DIA.(mm) 10 12 16 18 20 22 25


Slab Reinf. (A)
LAP LENGTH (mm) IN COLUMNS 400 500 600 650 700 800 900
400 600 700 800 900 1000 1250
drawing title
LAP LENGTH (mm) IN SLAB & BEAMS
PLAN OF SLAB
BOTTOM REINFORCEMENT
REINFORCEMENT&SEC.
designed project manager
ENG : DR-Majid Albana

. all dim. from ARCH D.W.G. checked scale


1-100
date
11 /2023
drawn job no. sheet no.

approved
12 ST/D/11