Field Operator:
Area 1 Merox compressors, Vessels, Columns, Date:
Shift:
Reactors and Tanks
Day / Night
Check Amps reading 1/Shift Amps should be less than < 3mAmp
Visual Check of Kerose at the
1/Shift Should be bright and clear
outlet of ECP (V-8308)
Analyze %spent in caustic 1/Shift, maintain <
Adjust Caustic injection rate 1/Shift 20-30%. For 1% drop in tank T-8301 level,
caustic injection rate is ~2.5 TPD
Air Injection 1/Shift T/D Adjust based on feed rate and feed RSH