You are on page 1of 17

EPANET

1410 40’ wide Street 1411

House size 60’x90’

1412 40’ wide Street 1415

House size 60’x90’

1415 40’ wide Street 1417

House size 60’x90’

1418 40’ wide Street 1420


Location for
Water Works
40’ wide street

6’ 14’
Plot Plot
20’ driveway

CL
EPANET
1410 40’ wide Street ≠9 1411
10 6

≠12 House size 60’x90’ ≠5

1412 9 40’ wide Street ≠8 1415 5

≠11 House size 60’x90’ ≠4

1415 40’ wide Street ≠7 1417


8 4
House size 60’x90’
≠10 ≠3

1418 7 2 ≠2 1420
40’ wide Street 3
≠6 ≠1
Location for
Water Works 1
60' x 90' house
No. of
residents per
plot = 12

Water demand
per person = 50 gpcd

Water
requirement
per plot = 600 gpd
0.417 gpm

Peak Factor = 2

Actual water
requirement = 0.83 gpm for one house

Node Node No. of plots Req. At each node


Between 6 - 10 14 11.67 5.8 5.8
5 - 9 28 23.33 11.7 11.7
4 - 8 28 23.33 11.7 11.7
3 - 7 14 11.67 5.8 5.8
Nodal Data Sheet:
Node No. E8levation (ft) Demand (gpm) Remarks
1 1420 - UGWT
2 1419.8 0
3 1420 5.8
4 1417 11.7
5 1415 11.7
6 1411 5.8
7 1418 5.8
8 1415 11.7
9 1412 11.7
10 1410 5.8
Pipe Data Sheet:
Pipe No. From Node To node Length (ft) C value
1 1 2 10 150
2 2 3 64 150
3 3 4 220 150
4 4 5 220 150
5 5 6 220 150
6 2 7 816 150
7 4 8 880 150
8 5 9 880 150
9 6 12 880 150
10 7 8 220 150
11 8 9 220 150
12 9 10 220 150
Minimum pressure Requirement
Vol. =1000 gallons
Time required for filling = 60 minutes
TANK Q = 1000/60= 17gpm
Static Head = 11+11+6+2.5+3=33.5’ ROOF
Total internal length = 125’ of 1” dia. pipe

Head loss = 15 psi/100ft


F/F
Actual head loss = 15 x 125/100
= 18.75 psi
= 18.75 x 2.31
=43.31 ft
G/F

STREET

WATER MAIN
Total head = static head + head loss
= 33.5 +43.3
= 76.81 ft + 12ft
= 33.25 psi + 5 psi
= 38psi
20 Maximum

Tank Bowl
6 Minimum
3 Initial
El.=1500’

El.=1420’
PROJECT EPANET
1410 40’ wide Street 1411

House size 60’x90’

1412 40’ wide Street 1415

House size 60’x90’

1415 40’ wide Street 1417

House size 60’x90’

1418 40’ wide Street 1420


Location for
Water Works
1625’ (40’ WIDE STREET) UNDERGROUND TANK
1600’
* means adjust plot numbers as per other plots data 40’x80’ (N=10+R)

40’x80’ (N=10+R)
R= last two digits of your registration number,

1620’ (40’ WIDE STREET) 1610’

30’x 50’ *

30’x 50’ *
(40’ WIDE STREET)

(40’ WIDE STREET)


(40’ WIDE STREET)

(40’ WIDE STREET)


30’x 30’x 30’x
30’x (40’ WIDE STREET)
50’ 50’ 50’
50’
(N=5 30’x 50’ * (N=5 (N=5
(N=5
+R) +R) +R)
+R)
30’x 50’ *
(40’ WIDE STREET)
30’x 50’ *
1610’ (40’ WIDE STREET) 1590’

40’x80’ (N=10+R)

40’x80’ (N=10+R)
1600’ (40’ WIDE STREET) 1580’
Note: Each street is 30’ wide, R is last two digit number from your registration e.g. for BCE173012, R=12

1460 1462

35’x70’ (N=R+8) 35’x70’ (N=R+8)

35’x70’ (N=R+8) 35’x70’ (N=R+8)

1465 1465
35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)

35’x70’ (N=R+5)
PARK

1465 1463
35’x70’ (N=R+8) 35’x70’ (N=R+8)

35’x70’ (N=R+8) 35’x70’ (N=R+8)


1462 1460
Vent

Inlet
Inlet Alum Tank
Inlet
Inlet Coagulation
Aeration
Reservoir
Reservoir

Filtration Supply
Sedimentation Chlorination

Filtered Water
Storage
Vent

Inlet

Alum Tank
Inlet
Coagulation

Reservoir
Aeration

Filtration

Chlorination
Filtered Water
Sedimentation Storage
EPANET
1408 40’ wide Street 1410

House size 60’x90’

1410 40’ wide Street 1412

House size 60’x90’

1406 40’ wide Street 1410

House size 60’x90’

1404 40’ wide Street 1408


Location for
Water Works

You might also like