MRI Wide Bore Systems

Company Name Canon Medical Systems USA Canon Medical Systems USA Canon Medical Systems USA Fujifilm Healthcare Americas Fujifilm Healthcare Americas GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers

Model Vantage Fortian 1.5T MR Vantage Orian 1.5T Vantage Galan 3T Echelon Oval Oasis Velocity Signa Premier 3T and Signa Signa Architect 3T and Signa Hero 3T Signa Pioneer 3T Signa Artist 1.5T, Signa Artist Signa Voyager 1.5T MR 5300 Ambition 1.5T S Ambition 1.5T X Elition 3T S Elition 3.0T X MR 7700 MAGNETOM Free.Max MAGNETOM Altea MAGNETOM Sola MAGNETOM Lumina MAGNETOM Vida MAGNETOM Prisma
Premier EVO (upgrade) Signa Architect Lift EVO (upgrade) and Signa
(upgrade) Artist Lift (upgrade)
FDA Cleared (year) 2022 v8 software 2022 v8 software 2022 v8 software 2012 2020 2017 with additional 2017 with additional 2022 2015 with additional 2017 with additional 2016 with additional 2021 2019 2019 2018 2018 2022 Yes (2021) Yes (2018) Yes (2018) Yes (2018) Yes (2017) Yes (2016)
clearance dates folowing clearance dates folowing clearance dates clearance dates following; clearance dates following
following 2022 for Signa Artist EVO
CE mark (year) N/S N/S N/S 2013 2020 2017 with additional 2017 with additional 2022 2015 with additional 2017 with additional 2016 with additional 2021 2018 2018 2017 2017 2022 Yes (2021) Yes (2018) Yes (2018) Yes (2018) Yes (2017) Yes (2015)
clearance dates folowing clearance dates folowing clearance dates clearance dates following; clearance dates following
following 2022 for Signa Artist EVO
Clinical Application Whole Body Whole Body Whole Body Whole body Whole body Ultra high-performance High performance whole- High performance High performance High performance whole- High performance whole- Whole body Whole body Whole body Whole body Whole body Whole body Whole-body High-performance whole-body High-performance whole-body High-performance whole-body High-performance whole-body High-performance whole-body
whole-body imaging body plus "beyond" whole-body whole-body body plus "beyond" Radiology body
radiology options options
What differentiates AiCE deep learning AiCE deep learning AiCE deep learning 74 cm Oval shaped High field open MR with 1. Air Technology: Air Recon 1. Air Technology: Air 1. Air Technology: Air 1. Air Technology: Air 1. Air Technology: Air Recon 1. Air Technology: Air The MR 5300 is built around The Ingenia Ambition built The Ingenia Ambition built The Philips Ingenia Elition S The Philips Ingenia Elition Philips MR 7700 imaging First 80 cm bore MRI system with a 1.5T open-bore comfort with 1.5T open-bore comfort with 3.0T open-bore comfort with 3.0T open-bore comfort with 3.0T advanced MRI system for
this system reconstruction, Pianissimo noise reconstruction, Pianissimo noise reconstruction, Pianissimo patient area - widest optimal patient comfort DL reconstruction, Air Coils, Recon DL reconstruction, Recon DL Recon DL DL reconstruction, Air Coils, Recon DL reconstruction, the fully sealed BlueSeal around the fully sealed around the fully sealed solution has the digital solution sets new directions for system, enhanced with XP helium independent infrastructure, advanced BioMatrix technology advanced BioMatrix technology advanced BioMatrix technology advanced BioMatrix technology enhanced high end clinical and
reduction hardware, 5 reduction hardware, 5 noise reduction hardware, 5 bore for the best patient for all exams; and Air Workflow. 2. Super-G Air Coils, and Air Workflow. reconstruction, Air Coils, reconstruction, Air Coils, and Air Workflow. 2. TDI Total Air Coils, and Air magnet, is designed to BlueSeal magnet, is BlueSeal magnet, is benefits of up to 40% SNR clinical research in 3.0T gradients and artificial requiring just 0.7l of liquid helium in for enhanced precision; for enhanced precision; for enhanced precision; for enhanced precision; research support.Benchmark
generations of non-contrast generations of non-contrast generations of non-contrast comfort and unobstructed viewing gradient coil technology with 2.TDI Total Digital Imaging and Air Workflow. 2. TDI and Air Workflow. 2. TDI Digital Imaging RF receive Workflow. 2. TDI Total simplify your MR designed to simplify your MR designed to simplify your MR gain, multi transmit 4-D with imaging based on new gradient intelligence. It is built to address a completely sealed DryCool maximum number of channels maximum number of channels maximum number of channels maximum number of channels XR 80/200 simultaneous
applications, Pianissimo ∑ and applications, Pianissimo ∑ and applications, Pianissimo ∑ accommodation; highest angle, 82 cm wide table, 20 direct water-cooling. 3. TDI RF receive with direct 1- Total Digital Imaging RF Total Digital Imaging RF with direct 1-to-1 conversion. Digital Imaging RF receive installation; operates with installation; operates with installation; operates with patient adaptive B1 correction and RF designs, as well as the a pressing need to deliver on the technology magnet design; our most 180; number of independent 228; number of independent 180; number of independent 228; number of independent gradients and industry leading
Pianissimo Zen quiet application Pianissimo Zen quiet application and Pianissimo Zen quiet guaranteed magnet cm in bore lateral Total Digital Imaging RF to-1 conversion. 3. Feet- receive with direct 1-to-1 receive with direct 1-to-1 3. Feet-first positioning for all with direct 1-to-1 only seven liters of liquid only seven liters of liquid only seven liters of liquid for each patient; enhancing digital benefits of up to 40% clinical expectations of today, compact MRI scanner - the smallest receiver channels that can be receiver channels that can be receiver channels that can be receiver channels that can be 3T magnet homogeneity.
suite, FAST 3D for TOF mVox, suite, FAST 3D for TOF mVox, application suite, FAST 3D uniformity; SynergyDrive motorized table receive with direct 1-to-1 first positioning for all conversion. 3. UHE conversion. 3. UHE exams. 4. Compatibility with conversion. 3. UHE Ultra- helium, delivers superb helium, delivers superb helium, delivers superb image contrast uniformity, SNR gain, multi transmit 4-D and to facilitate the most (<250 sq ft), lightest (<3.2 tons) used simultaneously in one used simultaneously in one used simultaneously in one used simultaneously in one Parallel transmit with TimTX
SSFP, auto scan assist SSFP, auto scan assist for TOF mVox, SSFP, auto with WIT provides movement, weight conversion. 4. The GE MR exams. 4. Compatibility Ultra-high Efficiency Ultra-high Efficiency "beyond" Radiology options. high Efficiency gradients image quality even for image quality even for image quality even for consistency and speed. with patient adaptive B1 demanding research programs. & easiest (hiehgt of < 2 m) single scan and in one single single scan and in one single single scan and in one single single scan and in one single TrueShape and ZOOMit
automated applications, Saturn automated applications, Saturn scan assist automated optimal workflow; 99% capacity of 660 lbs, IP- Continuum of upgradeability - with "beyond" Radiology gradients with high gradients with high 5. The GE MR Continuum of with high performance challenging patients, and challenging patients, and challenging patients, and Performs MRI exams up to correction for each patient. It is the system of choice for system to site; utlizing a 0.55T field FOV, all digital transmit/receive FOV, all digital transmit/receive FOV, all digital transmit/receive FOV, all digital transmit/receive technology. All digital transmit/
gradient technology, ceiling gradient technology, ceiling applications, Saturn gradient uptime guarantee and RAPID scan acceleration; this platform is available as options. 5. The GE MR performance and low performance and low upgradeability - this platform and low power performs MRI exams up to performs MRI exams up to performs MRI exams up to 50% faster. SmartSpeed AI Performs MRI exams up to highest quality diffusion imaging strength to expand clinical with direct RF; up to 60% more with direct RF; up to 60% more with direct RF; up to 60% more with direct RF; up to 60% more receive with direct RF; up to
camera and tablet UX camera and tablet UX technology, ceiling camera unlimited apps training 99% uptime guarantee and an upgrade for SIGNA Continuum of power consumption. 4. power consumption. 4. is available as an upgrade for consumption. 4. The GE 50% faster. Our lightest 50% faster. SmartSpeed AI 50% faster. SmartSpeed AI Recon further reduces scan 50% faster. SmartSpeed AI and advanced neuroscience. capabilities, together with our most SNR with Tim 4G; up to 50% SNR with Tim 4G; up to 50% SNR with Tim 4G; up to 50% SNR with Tim 4G; up to 50% 60% more SNR with Tim 4G; up
and tablet UX unlimited apps training Architect and Discovery upgradeability - this The GE MR Continuum The GE MR Continuum Optima MR450w systems MR Continuum of Breeze coils help cut patient Recon further reduces scan Recon further reduces scan time and provides excellent Recon further reduces scan Extend your scanning advanced hardware (BioMatrix improved workflow with Dot; improved workflow with Dot; improved workflow with Dot; improved workflow with Dot; to 50% improved workflow with
MR750w systems and IB 3T platform is available as an of upgradeability of upgradeability. and qualfying IB 60cm bore upgradeability. 5. change-over time up to 30% time and provides excellent time and provides excellent image quality. Seamless time and provides excellent capabilities with a fully & Tim4G) and software single digit breath-holds for 3-D single digit breath-holds for 3-D single digit breath-holds for 3-D single digit breath-holds for 3-D Dot
60cm bore systems where it upgrade for Discovery systems where it transitions Available in a moble image quality image quality MultiNuclei optional image quality. Seamless integrated multi-nuclei imaging (MyExam Companion, SMS, body imaging with Caipirinha body imaging with Caipirinha body imaging with Caipirinha body imaging with Caipirinha
transitions the bore to 70 cm MR750w IB systems the bore to 70 cm configuration MultiNuclei optional and spectroscopy solution to Compressed Sensing, Caipirinhia,
explore new clinical pathways Deep Resolve) technologies
Bore size (cm) 71 cm aperture 71 cm aperture 71 cm aperture 74 oval shape N/A - open architecture 70 cm 70 cm 70 cm 70 cm 70 cm 70cm 70 at isocenter, flares to 95 70 at isocenter, flares to 95 70 at isocenter, flares to 95 70 at isocenter, flares to 95 70 at isocenter, flares to 95 70 at isocenter, flares to 95 80 cm 70 cm 70 cm 70 cm 70 cm 60 cm
Magnet
Configuration Ultra-short bore Ultra-short bore Ultra-short bore Wide oval bore Open Widebore Widebore Widebore Widebore Widebore Widebore Wide bore Wide bore Wide bore Wide bore Wide bore Wide bore Open-bore MRI Open-bore MRI Open-bore MRI Open-bore MRI Open-bore MRI MRI
Type Superconducting Superconducting Superconducting Superconducting Superconducting iron core Super-conducting magnet Super-conducting magnet Super-conducting Super-conducting Super-conducting magnet Super-conducting magnet Superconducting Superconducting Superconducting Superconducting Superconducting Superconducting Superconducting with active Superconducting with active Superconducting with active Superconducting with active Superconducting with active Superconducting with active
magnet magnet with active shielding with active shielding magnet with active magnet with active with active shielding with active shielding shielding shielding shielding shielding shielding shielding
shielding shielding
Field strength, T 1.5T 1.5T 3T 1.5 T 1.2 T 3.0T 3.0T 3.0T 3.0T 1.5T 1.5T 1.5 1.5 1.5 3 3 3 0.55T 1.5T 1.5T 3.0T 3.0T 3.0T
Homogeneity (35 1.0 ppm 1.0 ppm 1.40 ppm 0.5 ppm Vrms @ 40 cm 0.3 ppm @ 35cm DSV Less than 0.50 ppm at 40 cm Less than 0.50 ppm at 40 Less than 0.50 ppm at Less than 0.50 ppm at 0.43 ppm at 40 cm DSV 0.43 ppm at 40 cm DSV Less than 0.55 ppm at 40 Less than 0.55 ppm at 40 cm Less than 0.55 ppm at 40 cm Less than 0.45 ppm at 40 cm Less than 0.45 ppm at 40 cm Less than 0.45 ppm at 40 cm 1.4 @ 40 cm DSV, Vrms 0.75 @ 40 cm DSV, Vrms 0.45 @ 40 cm DSV, Vrms 0.45 @ 40 cm DSV, Vrms 0.45 @ 40 cm DSV, Vrms 0.2 ppm @ 40 cm DSV,Vrms
or 40 cm DSV), DSV DSV cm DSV 40 cm DSV 40 cm DSV cm DSV DSV DSV DSV DSV DSV
Vrms, (guaranteed)
Homogeneity (35 0.30 ppm 0.30 ppm 1.20 ppm 0.2 ppm @ 40cm DSV Not Specified 0.25 ppm at 40 cm DSV 0.25 ppm at 40 cm DSV 0.25 ppm at 40 cm DSV 0.25 ppm at 40 cm DSV 0.33 ppm at 40 cm DSV 0.33 ppm at 40 cm DSV Less than 0.50 ppm at 40 Less than 0.50 ppm at 40 cm Less than 0.50 ppm at 40 cm Less than 0.40 ppm at 40 cm Less than 0.40 ppm at 40 cm Less than 0.40 ppm at 40 cm 1.0 @ 40 cm DSV, Vrms 0.65 @ 40 cm DSV, Vrms 0.37 @ 40 cm DSV, Vrms 0.37 @ 40 cm DSV, Vrms 0.37 @ 40 cm DSV, Vrms 0.1 ppm @ 40 cm DSV,Vrms
or 40cm DSV), cm DSV DSV DSV DSV DSV DSV
Vrms, (typical)
5-Gauss fringe 3 m radial / 5 m axial 3 m radial / 5 m axial 2.6 m radial and 4.6 m axial 2.5/4 3.3/4.2 2.8 m x 5.2 m at 5 Gauss 2.8 m x 5.2 m at 5 Gauss 2.8 m x 5.2 m at 5 2.8 m x 5.2 m at 5 2.5 m x 4.0 m at 5 Gauss 2.5 m x 4.0 m at 5 Gauss 2.4/4.0 2.4/4.0 2.4/4.0 3.05/4.95 3.05/4.95 3.05/4.95 2.5/4.0 m 2.5/4.0 m 2.5/4.0 m 2.65/4.65 m 2.65/4.65 m 3.4/5.9m
field, radial/axial, Gauss Gauss
m
Per-patient active Active, auto-active shimming, Active, auto-active shimming, Active, auto-active High order active shim High order active shim Yes Yes Yes Yes Yes Yes 3-D volume, 3 x linear 3-D volume, 3 x linear 3-D volume, 3 x linear 3-D volume, 3 x linear, 5 x 3-D volume, 3 x linear, 5 x HOS 3-D volume, 3 x linear, 5 x HOS 3 linear channels (1st order) 3 linear channels 3 linear channels, 5 nonlinear High order shim [3 linear (1st High order shim [3 linear (1st High order shim w/ 20 3D shim
shimming features slice selective FAT SAT slice selective FAT SAT shimming, slice selective technology technology HOS second-order channels (XQ order) and 5 non linear (2nd order) and 5 non linear (2nd planes
FAT SAT gradient) order)] order)]
Cryogen refill Greater to/less than 10 years Greater to/less than 10 years Greater to/less than 10 years Zero boil off, 6 years Once every 2 years Zero boil-off under normal Zero boil-off under normal Zero boil-off under Zero boil-off under Zero boil off under normal Zero boil off under N/A fully sealed N/A fully sealed N/A fully sealed Zero boil off Zero boil off Zero boil off N/A -fully sealed Zero-boil, approx 10 yrs Zero-boil, approx 10 yrs Zero-boil, approx 10 yrs Zero-boil, approx 10 yrs Zero-boil, approx 10 yrs
interval, year (zero boil-off) (zero boil-off) (zero boil-off) operating conditions operating conditions normal operating normal operating operating conditions normal operating
conditions conditions conditions
Finished (covered) 5,500 5,500 6,375 4,400 kg 14,200 kg 6,378 kg 6,378 kg with cryogens 7,561 kg with cryogens 7,561 kg with cryogens 3,300 kg with cryogens 3,300 kg with cryogens 2,300 2,300 2,300 4,800 4,800 4,800 3, 400 kg 4, 204 kg 4,204 kg 7,350 kg 7,350 kg 9,674 kg
gantry weight, kg
Finished (covered) 190 L, 240 W, 232 H 190 L, 240 W, 232 H 184.8 L, 240 W, 232 H Short bore length 160 x 273 x 254 x 216 2.09 x 2.52 x 2.5 m with 1.96 x 2.13 x 2.4 m with 2.09 x 2.52 x 2.5 m with 1.89 x 2.49 x 2.4 m with 179 cm magnet length 179 cm magnet length 1.62 x 1.88 x 2.30 1.62 x 1.88 x 2.30 1.62 x 1.88 x 2.30 1.62 x 1.88 x 2.30 1.62 x 1.88 x 2.30 1.62 x 1.88 x 2.30 175 x 230 x 207 145 x 234 x 215 146 x 234 x 215 186 x 245 x 215 186 x 245 x 215 215 x 250 x 231
gantry dimension 220 x 220 covers covers covers covers
(LxWxH), cm
Patient
Management/
Comfort
Minimum finished 71 aperture, 69 at middle of bore 71 aperture, 69 at middle of bore 71 aperture, 69 at middle of 74 cm at isocenter N/A - open architecture 70 cm bore width 70 cm bore width 70 cm bore width 70 cm bore width 70 cm bore width 70 cm bore width 70 70 70 70 70 70 80 cm 70 cm 70 cm 70 cm 70c m 60 cm
bore L-R diameter, bore
cm (closed
magnet),
measured at
isocenter
Minimum A-P 52.9 52.9 52.9 48 cm (top of spine coil 44 cm Detailed in product data Detailed in product data Detailed in product data Detailed in product data Detailed in product data Detailed in product data 58 58 58 58 58 58 54 cm 49 cm 49 cm 49 cm 49 cm 45 cm
Dimension with to top of bore); 54 cm sheet sheet sheet sheet sheet sheet
table inserted, cm, (top of table to top of
measured at bore)
isocenter, including
spine coil, but not
mat
Dockable table Optional Optional Optional Standard N/A Choice of integrated or Detachable table Detachable table Integrated table Detachable table Choice of integrated or Option, Flextrak transport Option, Flextrak transport Option, Flextrak transport Option, Flextrak transport Option, Flextrak transport Option, Flextrak transport Not available Option Option Option Option Option
(standard or detachable table detachable table
option)
Table width 66 66 66 75 total width (63 82 total width Approximately 56 cm See product data sheet Approximately 56 cm Approximately 56 cm See product data sheet Approximately 56 cm 63 63 63 63 63 63 56.8 cm 54.5 cm 54.5 cm 54.5 cm 54.5 cm 54.5 cm
(moving portion), moving portion)
cm
Table capacity, lbs 550 550 560 550 standard 660 standard 550 pounds with integrated 500 pounds 550 pounds 550 pounds 500 pounds 550 pounds with 550 550 550 550 550 550 485 lbs (standard); 705 lbs (optional) 550 lbs 550 lbs 550 lbs 550 lbs 550 lbs
table; 550 pounds with integrated table; 550
detachable table pounds with detachable
table
Table vertical Fixed table: 43 min - 84.5 scan; Fixed table: 43 min - 84.5 scan; Fixed table: 43 min - 84.5 50 to 84 50 - 90 53.5 to 93 cm continuous 70 cm to 93 cm continous 70 cm to 93 cm 52 to 93 cm contiuous 70 cm to 93 cm continous 52 to 93 cm contiuous 59-82 59-82 59-82 59-82 59-82 59-82 48 - 90 cm 52 - 97 cm 52 - 97 cm 52 - 97 cm 52 - 97 cm 52 - 97 cm
travel (min height dockable table: 55 (dock) 53.5 dockable table: 55 (dock) 53.5 scan; dockable table: 55 power driven with integrated power driven continous power driven power driven power driven power driven
— scanning (undock) min - 84.5 (dock) 87.5 (undock) min - 84.5 (dock) 87.5 (dock) 53.5 (undock) min - table; 70 to 93 cm
height), cm (undock) scan (undock) scan 84.5 (dock) 87.5 (undock) continuous power driven with
scan detachable table
Table longitudinal Standard: 145; extended: 205 Standard: 145; extended: 205 Standard 205 279 standard 223 standard 264 cm total cradle travel 205 cm total scan range 266 or 294 cm total 264 total cradle travel 205 cm total scan range 264 total cradle travel 275 275 275 275 275 275 215 cm 205 cm 205 cm 205 cm 205 cm 205 cm
movement range, cradle travel
cm
Feet-first imaging Yes, except head coil imaging Yes, except head coil imaging Yes, except head coil Yes, including brain No Most All Most Most All Most Yes, except head/neck Yes, except head/neck Yes, except head/neck Yes, except head/neck Yes, except head/neck imaging Yes, except head/neck imaging Yes, except for head/neck coil; brain Yes, except for head/neck coil; Yes, except for head/neck coil; Yes, except for head/neck coil; Yes, except for head/neck coil; Yes, except for head/neck coil;
for all regions imaging imaging imaging imaging imaging can be imaged feet first with flex coil brain can be imaged feet first brain can be imaged feet first brain can be imaged feet first brain can be imaged feet first brain can be imaged feet first
(yes/no) with flex coil with flex coil with flex coil with flex coil with flex coil
Gantry-mounted N/S N/S N/S Yes, in-room operator No Yes Yes Yes Yes Yes Yes No(optional) No(optional) Yes No(optional) Yes Yes Yes Yes Yes Yes Yes No
operator-controlled controlled
LCD (yes/no)
Patient cooling Yes Yes Yes Yes, 3 levels of N/A - open architecture Adjustable in-bore patient Adjustable in-bore patient Adjustable in-bore Adjustable in-bore Adjustable in-bore patient Adjustable in-bore patient 6 speed fan 6 speed fan 6 speed fan 6 speed fan 6 speed fan 6 speed fan In-bore ventilation (6 levels) In-bore ventilation (6 levels) In-bore ventilation (6 levels) In-bore ventilation (6 levels) In-bore ventilation (6 levels) In-bore ventilation (6 levels)
features adjustable in bore ventilation system ventilation system patient ventilation patient ventilation ventilation system ventilation system
ventilation system system
Operator call Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Patient — operator Yes Yes Yes Yes, 2 way in-bore Yes, 2 way in-bore 2-way in-bore intercom 2-way in-bore intercom 2-way in-bore intercom 2-way in-bore intercom 2-way in-bore intercom 2-way in-bore intercom Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
intercom communication communication system system system system system system
Patient illumination Yes Yes Yes 4 levels of adjustable in- Yes Adjustable in-bore lighting Adjustable in-bore lighting Adjustable in-bore Adjustable in-bore Adjustable in-bore lighting Adjustable in-bore In bore light with 3 intensity In bore light with 3 intensity In bore light with 3 intensity In bore light with 3 intensity In bore light with 3 intensity In bore light with 3 intensity In-bore lighting (6 levels) In-bore lighting (6 levels) In-bore lighting (6 levels) In-bore lighting (6 levels) In-bore lighting (6 levels) In-bore lighting (6 levels)
features bore lighting system system lighting system lighting system system lighting system settings. Optional Ambient settings. Optional Ambient settings. Optional Ambient settings. Optional Ambient settings. Optional Ambient settings. Optional Ambient
Experience Room and In- Experience Room and In- Experience Room and In- Experience Room and In-bore Experience Room and In-bore Experience Room and In-bore TV
bore TV bore TV bore TV TV TV
Gradient
Maximum STD 35; XGO 45 STD 35; XGO 45 STD 34; XGO 45 34 33 Super-G platform with 80 xTreme platform with 44 UHE platform with 36 UHE platform with 36 For Signa Artist, xTreme UHE platform with 36 33 33 45 36 45 65 26 mT/m 33 mT/m 33 mT/m for XJ gradients 36 mT/m for XK gradients 45 mT/m for XQ gradients 80 mT/m for XR gradients
amplitude, single mT/m all axes simultaneous mT/m all axes mT/m (45 mT/m mT/m (45 mT/m platform with 44 mT/m all mT/m (45 mT/m (standard); 45 mT/m for XQ (standard) (standard); 60 mT/m for XT (standard)
axis, mT/m (X, Y simultaneous equivalent performance) equivalent performance) axes simultaneous. For Signa equivalent performance) gradients (optional) gradients (optional)
and Z) all axes simultaneous all axes simultaneous Artist EVO 44 mT/m all axes all axes simultaneous
simuntaneous
Maximum slew STD 155 STD 155; XGO 200 STD 200; XGO 200 150 100 Super-G platform with 200 T/ xTreme platform with 200 UHE platform with 150 UHE platform with 150 For SIGNA™ Artist, xTreme UHE platform with 150 T/ 120 120 200 160 220 220 45 T/m/s 125 T/m/s 125 T/m/s (standard); 200 T/m/ 200 T/m/s 200 T/m/s 200 T/m/s
rate, single axis, T/ m/s all axes simultaneous T/m/s all axes T/m/s (200 T/m/s T/m/s (200 T/m/s platform with 200 T/m/s all m/s (200 T/m/s s for XQ gradients (optional)
m/s (X, Y and Z) simultaneous equivalent performance) equivalent performance) axes simultaneous. For equivalent performance)
all axes simultaneous all axes simultaneous SIGNA™ Artist EVO 170 T/m/ all axes simultaneous
s all axes simultaneous.
Cooling system Water cooled Water cooled Water cooled Water-cooled Water-cooled All-hollow with direct water Water cooled Water cooled Water cooled Water cooled Water cooled Direct liquid cooling Direct liquid cooling gradient Direct liquid cooling gradient Direct liquid cooling gradient Direct liquid cooling gradient Direct liquid cooling gradient coil Water-cooled Water-cooled Water-cooled Water-cooled Water-cooled Water-cooled
type cooling gradient coil with hollow coil with hollow conductors coil with hollow coil with hollow conductors coil with hollow conductors with hollow conductors
conductors
Computer System
CPU type 8-core dual-processor system 8-core dual-processor system N/S Core i3 3.5GHz Xeon 3.8GHz Intel Xeon W-2123 CPU with Intel Xeon W-2123 CPU Intel Xeon W-2123 CPU Intel Xeon W-2123 CPU Intel Xeon W-2123 CPU with Intel Xeon W-2123 CPU 3.6 GHz six core Intel 3.6 GHz six core Intel 3.6 GHz six core Intel 3.6 GHz six core Intel 3.3 GHz ten core Intel 3.3 GHz ten core Intel Intel CFL E-2226GE Intel Xeon (6 Core) Intel Xeon (6 Core) Intel Xeon (6 Core) Intel Xeon (6 Core) Intel Xeon (6 Core)
(16 CPUs) (16 CPUs) Scientific Linux operating with Scientific Linux with Scientific Linux with Scientific Linux Scientific Linux operating with Scientific Linux processors processors processors processors processors processors
system operating system operating system operating system system operating system
CPU memory size, 32 GB 32 GB N/S 16 GB 16 GB 64 GB 64 GB 64 GB 64 GB 64 GB 64 GB 32 GB 32 GB 32 GB 32 GB 32 GB 32 GB 64 GB 64 GB 64 GB 64 GB 64 GB 64 GB
MB
Reconstruction 6-core dual-processor system 6-core dual-processor system N/S Xeon x1275, 3.5GHz Xeon 2.2GHz - (Dual) Dual Intel Xeon Gold 6130 Dual Intel Xeon Gold 5118 Dual Intel Xeon Gold Dual Intel Xeon Gold Dual Intel Xeon Gold 5118 Dual Intel Xeon Gold 5118 3.6 GHz six core Intel 3.6 GHz six core Intel 3.6 GHz six core Intel 3.6 GHz eight core Intel 3.6 GHz eight core Intel 3.6 GHz eight core Intel Intel CFL E-2124G 2x Intel Xeon _ E5-2640v3 8- 2x Intel Xeon _ E5-2640v3 8- 2x Intel Xeon _ E5-2640v3 8- 2x Intel Xeon _ E5-2640v3 8- 2x Intel Xeon _ E5-2640v3 8-
hardware (12 CPUs) (12 CPUs) with Scientific Linux with Scientific Linux 5118 with Scientific 5118 with Scientific with Scientific Linux with Scientific Linux processors processors processors processors processors processors Core Core Core Core, 2x Intel Xeon _ E5-2680v3 Core, 2x Intel Xeon _ E5-2680v3
operating system and the operating system and the Linux operating system Linux operating system operating system and the operating system and the 10-Core (128 ch optional) 10-Core (128 ch optional)
Orchestra reconstruction Orchestra reconstruction and the Orchestra and the Orchestra Orchestra reconstruction Orchestra reconstruction
platform standard platform standard reconstruction platform reconstruction platform platform standard platform standard
standard standard
Reconstruction 128 GB 128 GB N/S 16 GB 32 GB At least 192GB with 81,000 At least 128GB standard At least 128GB standard At least 128GB standard At least 128GB standard with At least 128GB standard 32 GB 32 GB 32 GB 32 GB 32 GB 32 GB 32 GB 64 GB 64 GB 64 GB 64 GB (standard 64 ch), 256 GB 64 GB (standard 64 ch), 256 GB
memory size, MB 2D FFTs/second standard with 63,000 2D FFTs/ with 63,000 2D FFTs/ with 63,000 2D FFTs/ 63,000 2D FFTs/second with 63,000 2D FFTs/ (optional 128 ch) (optional 128 ch)
second standard second standard second standard standard second standard
Image storage USB DVD 9.4 GB / Blu-ray 50 GB DVD 9.4 GB / Blu-ray 25 GB HDD, DVD, CD-R HDD, DVD, CD-R Hard disk storage; CD/DVD Hard disk storage; CD/DVD Hard disk storage; CD/ Hard disk storage; CD/ Hard disk storage; CD/DVD Hard disk storage; CD/ External storage via USB External storage via USB port External storage via USB port External storage via USB port External storage via USB port External storage via USB port CD/DVD driver - not built in, but CD/DVD-R, SDHC Card Reader CD/DVD-R, SDHC Card Reader CD/DVD-R, SDHC Card Reader CD/DVD-R, SDHC Card Reader CD/DVD-R, SDHC Card Reader
media type drive drive DVD drive DVD drive drive DVD drive port DICOM STD-CTMR and DICOM STD-CTMR and E-MR DICOM STD-CTMR and E-MR DICOM STD-CTMR and E-MR DICOM STD-CTMR and E-MR DICOM STD-CTMR and E-MR optionally connectable by USB
E-MR format format format format format format
Image storage Approximately 1,1680,000 Approximately 1,120,000 images Approximately 1,680,000 HDD 320 GB; DVD 4.7 HDD 1 TB; DVD 4.7 GB; CD- 1,024 GB SSD 1,024 GB SSD 1,024 GB SSD 1,024 GB SSD 1,024 GB SSD 1,024 GB SSD Greater than or equal to Greater than or equal to Greater than or equal to Greater than or equal to Greater than or equal to Greater than or equal to 600,000 N/A CD-R (4,000 256 x 256); DVD-R CD-R (4,000 256 x 256); DVD-R CD-R (4,000 256 x 256); DVD-R CD-R (4,000 256 x 256); DVD-R CD-R (4,000 256 x 256); DVD-R
media image images 256 x 256 256 x 256 images 256 x 256 GB; CD-R for an exam R for an exam 600,000 images (256 x 256) 600,000 images (256 x 256) 600,000 images (256 x 256) 600,000 images (256 x 256) 600,000 images (256 x 256) images (256 x 256) (25,000 images 256 x 256) (25,000 images 256 x 256) (25,000 images 256 x 256) (25,000 images 256 x 256) (25,000 images 256 x 256)
capacity
DICOM 3.0 classes Storage SCU, print SCU, DICOM Yes (DICOM basic, print SCU, Yes (DICOM basic, print SCU, Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes yes yes yes
supported (yes/no) media, and MWM SCU; storage storage SCU and DICOM media storage SCU and DICOM
commitment, Q/R SCU, Q/R SCP standard; storage commitment, media standard; storage
query-retrieve SCP, query-retrieve commitment, query-retrieve
SCU, MWM SCU and MPPS SCU SCP, query-retrieve SCU,
optional) MWM SCU and MPPS SCU
optional)
Display monitor 24 in. LCD (1,920 x 1,200) 24 in. LCD (1,920 x 1,200) 24 in. LCD (1,920 x 1,200) 24in. diagonal (1,920 x 24in. diagonal (1,920 x 24.1 in. LCD flat panel with 24.1 in. LCD flat panel with 24.1 in. LCD flat panel 24.1 in. LCD flat panel 24.1 in. LCD flat panel with 24.1 in. LCD flat panel Greater than or equal to 23- Greater than or equal to 23- Greater than or equal to 23- Greater than or equal to 23-in, Greater than or equal to 23-in, Greater than or equal to 23-in, 1920 × 1200 flatscreen, 24 in. Two 1,900 x 1,200 flatscreen, 24 Two 1,900 x 1,200 flatscreen, 24 Two 1,900 x 1,200 flatscreen, 24 Two 1,900 x 1,200 flatscreen, 24 Two 1,900 x 1,200 flatscreen,
displayable area 1,200) 1,200) 1,920 x 1,200 dot resolution 1,920 x 1,200 dot with 1,920 x 1,200 dot with 1,920 x 1,200 dot 1,920 x 1,200 dot resolution with 1,920 x 1,200 dot in, 1,920 x 1,200 resolution in, 1,920 x 1,200 resolution in, 1,920 x 1,200 resolution 1,920 x 1,200 resolution 1,920 x 1,200 resolution 1,920 x 1,200 resolution diagonal in. diagonal in. diagonal in diagonal in diagonal 24 in diagonal
(LxW), cm resolution resolution resolution resolution
Simultaneous scan Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
and reconstruction,
(yes/no)
RF System
Channels 16 / 32 128 128 16 channel, 32 channel 16 channel 146-channel TDI Total Digital 64-channel TDI Total 65-channel TDI Total 33-channel TDI Total 64-channel TDI Total Digital 33-channel TDI Total Digital, channel independent Digital, channel independent Digital, channel independent Digital, channel independent Digital, channel independent Digital, channel independent 24 with Tim [51x24]; DirectRX: • 32 with Tim [180x32]; DirectRF: • 32 with Tim [204x32]; 48 with 32 with Tim [180x32]; DirectRF: • 32 with Tim [204x32]; 48 with 48 with Tim [204x48]; 64 with
(minimum, Imaging with direct 1-to-1 Digital Imaging with direct Digital Imaging with Digital Imaging with Imaging with direct 1-to-1 Digital Imaging with Optical RF system • Digital-out Transmit and Receive system Tim [204x48] 64 with Tim Transmit and Receive system Tim [204x48]; 64 with Tim Tim [204x64] DirectRF: •
maximum signal conversion 1-to-1 signal conversions direct 1-to-1 signal direct 1-to-1 signal signal conversions standard; direct 1-to-1 signal design integrated at the magnet. • Full [204x64]; DirectRF: • Transmit integrated at the magnet. • Full [204x64]; DirectRF: • Transmit Transmit and Receive system
configuration) standard; 96ch and 128ch conversions standard; conversions standard; 96ch and 128ch options conversions standard; digital-in and digital-out and Receive system integrated digital-in and digital-out and Receive system integrated integrated at the magnet. • Full
options 97ch option 65ch and 97ch options 49ch and 65ch options (transmit and receive) • Optical at the magnet. • Full digital-in (transmit and receive) • Optical at the magnet. • Full digital-in digital-in and digital-out
cables from magnet to and digital-out (transmit and cables from magnet to and digital-out (transmit and (transmit and receive) • Optical
equipment room receive) • Optical cables from equipment room receive) • Optical cables from cables from magnet to
magnet to equipment room magnet to equipment room equipment room
Parallel imaging Speeder, k-t Speeder, Speeder, k-t Speeder, Speeder, k-t Speeder, RAPID - Image; k-RAPID: RAPID - Image; k-RAPID: k- ASSET 1-D image-based; ASSET 1-D image-based; ASSET 1-D image- ASSET 1-D image- ASSET 1-D image-based; ARC ASSET 1-D image-based; k-t Blast: K Space, k-t k-t Blast: K Space, k-t SENSE: k-t Blast: K Space, k-t SENSE: k-t Blast: K Space, k-t SENSE: k-t Blast: K Space, k-t SENSE: K k-t Blast: K Space, k-t SENSE: K All coils are compatible with full iPAT All coils are compatible with full All coils are compatible with full All coils are compatible with full All coils are compatible with full All coils are compatible with full
features (name, Compressed Speeder, Exsper Compressed Speeder, Exsper Compressed Speeder, k-space space; IP-RAPID ARC 1-D/2-D hybrid image- ARC 1-D/2-D hybrid image- based; ARC 1-D/2-D based; ARC 1-D/2-D 1-D/2-D hybrid image-based; ARC 1-D/2-D hybrid SENSE: K Space, SENSE: K Space, SENSE: Image, K Space, SENSE: Image, K Space, SENSE: Image, Space, SENSE: Image, Space, SENSE: Image, techniques: T-PAT: image, mSENSE: iPAT techniques: T-PAT: image, iPAT techniques: T-PAT: image, iPAT techniques: T-PAT: image, iPAT techniques: T-PAT: image, iPAT techniques: T-PAT: image,
image/K-space) Exsper based; HyperSense based; HyperSense hybrid image-based; hybrid image-based; HyperSense compressed image-based; Image, Compressed SENSE: Compressed SENSE: Image, Compressed SENSE: Image, Compressed SENSE: Image, Compressed SENSE: Image, Compressed SENSE: Image, image, Grappa: K-space, Caipirinha: mSENSE: image, Grappa: K- mSENSE: image, Grappa: K- mSENSE: image, Grappa: K- mSENSE: image, Grappa: K- mSENSE: image, Grappa: K-
Name1: K-space compressed sensing compressed sensing HyperSense HyperSense sensing (option), HyperCube HyperSense compressed Image, SmartSpeed: Image, SmartSpeed: Image, SmartSpeed: Image, SmartSpeed: Image, SmartSpeed: Image, MultiBand SmartSpeed: Image, MultiBand K-space, SMS: K-space. Deep space, Caipirinha: K-space, SMS: space, Caipirinha: K-space, SMS: space, Caipirinha: K-space, SMS: space, Caipirinha: K-space, SMS: space, Caipirinha: K-space,
version; Name2: (option), HyperCube tailored (option), HyperCube compressed sensing compressed sensing tailored RF (option), sensing (option), MultiBand SENSE: Image MultiBand SENSE: Image MultiBand SENSE: Image MultiBand SENSE: Image SENSE: Image SENSE: Image Resolve AI based reconstruction K-space. Deep Resolve AI based K-space. Deep Resolve AI based K-space. Deep Resolve AI based K-space. Deep Resolve AI based SMS: K-space
image (i.e., grappa: RF (option), HyperBand tailored RF (option), (option), HyperCube (option), HyperCube HyperBand simultaneous HyperCube tailored RF reconstruction reconstruction reconstruction reconstruction
K-space, mSENSE: simultaneous multi-slice HyperBand simultaneous tailored RF (option), tailored RF (option), multi-slice (option) (option), HyperBand
image) (option) multi-slice (option) HyperBand HyperBand simultaneous multi-slice
simultaneous multi-slice simultaneous multi-slice (option)
(option) (option)
Analog-to-digital Yes Yes Yes Yes (Digital Drive DX) - No Yes with direct 1-to-1 Yes with direct 1-to-1 Yes with direct 1-to-1 Yes with direct 1-to-1 Yes with direct 1-to-1 Yes with direct 1-to-1 No, at the coil. No, at the coil. No, at the coil. No, at the coil. No, at the coil. No, at the coil. Yes Yes Yes Yes Yes Yes
conversion at standard conversion conversion conversion conversion conversion conversion
gantry (yes/no)

© 2023 WAINSCOT MEDIA. ALL RIGHTS RESERVED.


MRI Wide Bore Systems
Company Name Canon Medical Systems USA Canon Medical Systems USA Canon Medical Systems USA Fujifilm Healthcare Americas Fujifilm Healthcare Americas GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers Siemens Healthineers

Optical N/S N/S N/S Yes (Digital Drive DX) - No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
transmission standard
Coils (Standard/
Optional, # of
Elements, RF
Channels, Parallel
Imaging Support)
Brain Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Standard, 19, 15, RAPID Standard, 18,15, RAPID HNU up to 61ch when HNU up to 50ch when HNU up to 45ch when HNU up to 49ch when HNU up to 28ch when HNU up to 32ch when Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in head Head/Neck Coil- 12 channels BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coilm- 20 - channel Head/Neck
elements, parallel imaging elements, parallel imaging elements, parallel imaging combined with Air PA and Air combined with GEM PA combined with TDI PA combined with TDI PA combined with GEM PA and combined with TDI PA head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense coil, dS-Sense 16 channels; BioMatrix; Head/ 16 channels; BioMatrix Head/ 16 channels; BioMatrix Head/ 16 channels; BioMatrix Head/ (standard) 64-channel
capable capable capable 30ch AA; 48ch brain coil and Air AA; 48ch brain coil and Air MP; 48ch brain and 16ch Flex array; TDI AA. All parallel imaging and TDI AA. All parallel Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - (optional) Head/neck, 32-
option. All parallel imaging option. All parallel imaging coil option. All parallel 48ch brain coil option. compatible imaging compatible BioMatrix CoilShim BioMatrix CoilShim BioMatrix CoilShim BioMatrix CoilShim; BioMatrix channel head (optional)
compatible compatible imaging compatible All parallel imaging Head/Neck 64 coil - 64 channels
compatible (55 in the head region) -
BioMatrix CoilShim
Head Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Standard, 19, 15, RAPID Standard, 18,15, RAPID HNU up to 61ch when HNU up to 50ch when HNU up to 45ch when HNU up to 49ch when HNU up to 28ch when HNU up to 32ch when Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in Standard 15, digitization in head Head/Neck Coil - 12 channels BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - 20 - channel Head/Neck
elements, parallel imaging elements, parallel imaging elements, parallel imaging combined with Air PA and Air combined with GEM PA combined with TDI PA combined with TDI PA combined with GEM PA and combined with TDI PA head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense head coil, dS-Sense coil, dS-Sense 16 channels; BioMatrix Head/ 16 channels; BioMatrix Head/ 16 channels; BioMatrix Head/ 16 channels; BioMatrix Head/ (standard) 64-channel
capable capable capable 30ch AA; 48ch brain coil and Air AA; 48ch brain coil and Air MP; 48ch brain and 16ch Flex array; TDI AA. All parallel imaging and TDI AA. All parallel Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - Neck 20 coil - 20 channels - (optional) Head/neck, 32-
option. All parallel imaging option. All parallel imaging coil option. All parallel 48ch brain coil option. compatible imaging compatible BioMatrix CoilShim BioMatrix CoilShim BioMatrix CoilShim BioMatrix CoilShim; BioMatrix channel head (optional)
compatible. compatible. imaging compatible. All parallel imaging Head/Neck 64 coil - 64 channels
compatible (55 in the head region) -
BioMatrix CoilShim
Spine Atlas Speeder spine, 32 Atlas Speeder spine, 32 Atlas Speeder spine, Standard, 18, 16, RAPID Standard, 18,16, RAPID Embedded TDI 32ch PA; Embedded GEM PA 40ch Embedded TDI 32ch PA. Embedded TDI 32ch PA. Embedded GEM PA 40ch with Embedded TDI 32ch PA. Up to 59 Channel Total Standard 44 Channel dS- Standard 44 Channel dS- Standard 44 Channel dS- Standard 44 Channel dS- Standard 44 Channel dS-SENSE Spine coil - 9 channels BioMatrix Spine 24 RS coil - BioMatrix Spine 24 RS coil - BioMatrix Spine 24 RS coil - BioMatrix Spine 24 RS coil - Spine 32 matrix array, receive
elements, parallel imaging elements, parallel imaging standard, 40 elements, embedded 60ch Air PA with variable density Parallel imaging Parallel imaging variable density design. Parallel imaging Neuro SENSE SENSE SENSE SENSE 24 channels - up to 12 per 24 channels - up to 12 per 24 channels - up to 12 per 24 channels - up to 12 per only, DirectConnect cable-less
parallel imaging capable option. All parallel imaging desgin. Parallel imaging compatible compatible Parallel imaging compatible compatible station - BioMatrix Respiratory station - BioMatrix Respiratory station - BioMatrix Respiratory station - BioMatrix Respiratory technology, Dual Density Signal
compatible compatible Sensor Sensor; BioMatrix Spine 32 RS Sensor Sensor; BioMatrix Spine 32 RS Transfer
coil - 32 channels - up to 16 per coil - 32 channels - up to 16 per
station - BioMatrix Respiratory station - BioMatrix Respiratory
Sensor; BioMatrix Spine 48 RS Sensor; BioMatrix Spine 72 RS
coil - 48 channels - up to 24 per coil - 72 channels - up to 36 per
station - BioMatrix Respiratory station - BioMatrix Respiratory
Sensor Sensor
Neck AtlasSpeeder head/neck, 16 AtlasSpeeder head/neck, 16 Atlas Speeder head/neck, 16 Standard, 18, 12 to 16, Standard 13, 10, RAPID HNU up to 61ch when HNU up to 61ch when HNU up to 61ch when HNU up to 61ch when HNU up to 28ch when HNU up to 32ch when Standard 15, digitization in Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, channel Head/Neck Coil - 12 channels BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - 20 - channel Head/Neck
elements, parallel imaging elements, parallel imaging elements, parallel imaging RAPID combined with Air PA and Air combined with Air PA and combined with Air PA combined with Air PA combined with GEM PA and combined with TDI PA head coil, dS-Sense, Breeze channel independent, dS- channel independent, dS- channel independent, dS- channel independent, dS-Sense independent, dS-Sense 16 channels (neck part 4 16 channels (neck part 4 16 channels (neck part 4 16 channels (neck part 4 (standard) 64-channel
capable capable capable 30ch AA. All parallel imaging Air 30ch AA. All parallel and Air 30ch AA. All and Air 30ch AA. All TDI AA. All parallel imaging and TDI AA. All parallel S or M Sense Sense Sense channels); BioMatrix Head/Neck channels); BioMatrix Head/Neck channels); BioMatrix Head/Neck channels) BioMatrix Head/Neck (optional) Head/neck, 32-
compatible imaging compatible parallel imaging parallel imaging compatible imaging compatible 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part channel head (optional)
compatible compatible 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix
CoilShim; BioMatrix Head/Neck
64 coil - 64 channels (neck part
9 channels) - BioMatrix CoilShim
Neurovascular Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Optional, 22, 15, RAPID Standard 20,16, RAPID HNU up to 61ch when HNU up to 50ch when HNU up to 45ch when HNU up to 49ch when HNU up to 28ch when HNU up to 32ch when Standard 15, digitization in Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, channel Head/Neck Coil - 12 channels BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - 20 - channel Head/Neck
elements, parallel imaging elements, parallel imaging elements, parallel imaging combined with Air PA and Air combined with GEM PA combined with TDI PA combined with TDI PA combined with GEM PA and combined with TDI PA head coil, dS-Sense, Breeze channel independent, dS- channel independent, dS- channel independent, dS- channel independent, dS-Sense independent, dS-Sense 16 channels (neck part 4 16 channels (neck part 4 16 channels (neck part 4 16 channels (neck part 4 (standard) 64-channel
capable capable capable 30ch AA; 48ch brain coil and Air AA; 48ch brain coil and Air MP; 48ch brain and 16ch Flex array; TDI AA. All parallel imaging and TDI AA. All parallel S or M Sense Sense Sense channels); BioMatrix Head/Neck channels); BioMatrix Head/Neck channels); BioMatrix Head/Neck channels) BioMatrix Head/Neck (optional) Head/neck, 32-
option. All parallel imaging option. All parallel imaging coil option. All parallel 48ch brain coil option. compatible imaging compatible 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part channel head (optional)
compatible compatible imaging compatible All parallel imaging 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix
compatible CoilShim; BioMatrix Head/Neck
64 coil - 64 channels (neck part
9 channels) - BioMatrix CoilShim
Shoulder Shoulder Speeder, optional, 6 Shoulder Speeder, optional, 6 Shoulder Speeder, optional, 6 Standard, 8, 8, RAPID Standard, 6, 6, RAPID Options: 16ch adaptable Options: 16ch adaptable Options: 16ch adaptable Options: 16ch adaptable Options: 16ch adaptable Options: 16ch adaptable dS MSK 16 Breeze Coil Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, channel Contour S coil - 6 channels Shoulder Shape 16 channels; Shoulder Shape 16 channels; Shoulder Shape 16 channels; Shoulder Shape 16 channels; Shoulder Large and Shoulder
elements, parallel imaging elements, parallel imaging elements, parallel imaging shoulder; Air 21/20ch MP shoulder; Air 21/20ch MP shoulder; Air 21/20ch shoulder; Air 21/20ch shoulder; Air 21/20ch MP shoulder; Air 21/20ch MP channel independent, dS- channel independent, dS- channel independent, dS- channel independent, dS-Sense independent, dS-Sense Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; Small 16; Flex Large 4 and Flex
capable arrays; 16ch flex array. All arrays; 16ch flex array. All MP arrays; 16ch flex MP arrays; 16ch flex arrays; 16ch flex array. All arrays (require 49chs); Sense Sense Sense Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels Small 4
parallel imaging compatible parallel imaging array. All parallel array. All parallel parallel imaging compatible 16ch flex array. All
compatible imaging compatible imaging compatible parallel imaging
compatible
Body/torso Atlas body Speeder, 16 Atlas body Speeder, 16 Atlas body Speeder, Standard 8, up to 16 ch Standard, 8,8 (WIT Torso Options: Air 30ch AA; 16ch Options: Air 30ch AA; 16ch Options: Air 30ch AA; Options: Air 30ch AA; Options: Air 30ch AA; Air Options: Air 16ch AA; dS TorsoCardiac 20 Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital coil, 1 x BioMatrix Contour L coil (6ch) + Body 12 + Spine 24: - 21 2 x Body 12 + Spine 24: - up to Body 12 + Spine 24: - 21 2 x Body 12 + Spine 24: - up to 2 x Body 12 + Spine 24: - up to
elements, parallel imaging elements, parallel imaging standard, 16 elements, with Spine coil, RAPID Coil A) RAPID; optional TDI AA; Air 21/20 MP arrays. TDI AA; Air 21/20 MP 16ch TDI AA; Air 21/20 16ch TDI AA; Air 21/20 16ch AA; 16ch TDI AA; Air 16ch TDI AA; Air 21/20 Channel coil, dS-Sense coil, dS-Sense coil, dS-Sense coil, dS-Sense dS-Sense Spine Coil (9ch); 2 x BioMatrix channels; 2 x Body 12 + Spine 32 channels in one FoV; 2 x channels; 2 x Body 12 + Spine 32 channels in one FoV; 2 x 32 channels in one FoV; 2 x
parallel imaging capable optional 20, up to 32 ch 16,16 (WIT Torso A+B) All parallel imaging arrays. All parallel imaging MP arrays. All parallel MP arrays. All parallel 21/20 MP arrays. All parallel MP arrays (require Contour L coil (12ch) + Spine Coil 24: - up to 32 channels in the Body 18 + Spine 32: - up to 40 24: - up to 32 channels in the Body 18 + Spine 32: - up to 40 Body 18 + Spine 32: - up to 40
with Spine coil, RAPID RAPID compatible compatible imaging compatible imaging compatible imaging compatible 49chs). All parallel (9ch) FOV channels in one FoV; Body 30 + FOV channels in one FoV; Body 30 + channels in one FoV; Body 30 +
imaging compatible Spine 32: - up to 46 channels in Spine 32: - up to 46 channels in Spine 32:- up to 46 channels in
one FoV one FoV one FoV
Knee Extra large knee, optional, 7 Extra large knee, optional, 7 Extra large knee, optional, 7 Standard, 12, 12, RAPID Standard, 6, 6, RAPID Options: 18ch T/R knee; Air Options: 18ch T/R knee; Air Options: 18ch T/R knee; Options: 18ch T/R knee; Options: 16ch T/R knee; Air Options: 16ch T/R knee; dS MSK 16 Breeze Coil Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS-SENSE Optional 16 Channel dS-SENSE 1 x Contour S coil (6ch); 2 x Contour Tx/Rx Knee 18 channels Tx/Rx Knee 18 channels Tx/Rx Knee 18 channels Tx/Rx Knee 18 channels Tx / Rx Knee 15 Flare; Flex
elements, parallel imaging elements, parallel imaging elements, parallel imaging 21/20ch MP arrays; 16ch flex 21/20ch MP arrays; 16ch Air 21/20ch MP arrays; Air 21/20ch MP arrays; 21/20ch MP arrays; 16ch flex Air 21/20ch MP arrays SENSE SENSE SENSE S coils (12ch); 1 x Contour M coil (transmit/receive); Flex large 4 (transmit/receive); Flex large 4 (transmit/receive); Flex large 4 (transmit/receive); Flex large 4 Large 4 and Flex Small 4
capable; knee speeder Tx/Rx, capable; knee speeder Tx/Rx, capable; knee speeder Tx/ array. All parallel imaging flex array. All parallel 16ch flex array. All 16ch flex array. All array. All parallel imaging (require 49chs); 16ch flex (12ch) channels; Ultraflex 18 large channels; Ultraflex 18 large channels; Ultraflex 18 large channels; Ultraflex 18 large
optional, 16 elements, parallel optional, 16 elements, parallel Rx, optional, 16 elements, compatible imaging compatible parallel imaging parallel imaging compatible array. All parallel imaging
imaging capable imaging capable parallel imaging capable compatible compatible compatible
Cardiac 32 elements with 16 anterior and 32 elements with 16 anterior and Atlas body Speeder, Optional, 6, up to 16 with Standard, 8,8, RAPID Options: Air 30ch AA; Air Options: Air 30ch AA; Air Options: Air 30ch AA; Air Options: Air 30ch AA; Air Options: Air 30ch AA; Air Options: Air 16ch AA; dS TorsoCardiac 20 Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital Standard 32 Channel, digital coil, N/A Body 12 + Spine 24: - 21 Body 12 + Spine 24: - 21 Body 12 + Spine 24: - 21 Body 12 + Spine 24: - 21 2 x Body 12 + Spine 24: - up to
16 posterior, parallel imaging 16 posterior, parallel imaging standard, 16 elements, P-head and spine coil, 21/20ch MP array; TDI 16ch 21/20ch MP array; TDI 21/20ch MP array; TDI 21/20ch MP array; TDI 16ch AA; Air 21/20ch MP 16ch TDI AA; Air 21/20 Channel coil, dS-Sense coil, dS-Sense coil, dS-Sense coil, dS-Sense dS-Sense channels; 2 x Body 12 + Spine channels; 2 x Body 12 + Spine channels; 2 x Body 12 + Spine channels; 2 x Body 12 + Spine 32 channels in one FoV; 2 x
capable, optional capable, optional parallel imaging capable RAPID AA. All parallel imaging 16ch AA. All parallel 16ch AA. All parallel 16ch AA. All parallel array; TDI 16ch AA. All MP arrays (require 24: - up to 32 channels in the 24: - up to 32 channels in the 24: - up to 32 channels in the 24: - up to 32 channels in the Body 18 + Spine 32: - up to 40
compatible imaging compatible imaging compatible imaging compatible parallel imaging compatible 49chs). All parallel FOV FOV; Body 18 + Spine 32: - 30 FOV FOV; Body 18 + Spine 32: - 30 channels in one FoV; Body 30 +
imaging compatible channels; 2 x Body 18 + Spine channels; 2 x Body 18 + Spine Spine 32: - up to 46 channels in
32: - up to 46 channels in the 32: - up to 46 channels in the one FoV
FoV; Body 30 + Spine 32: - up to FoV; Body 30 + Spine 32: - up to
46 channels in the FOV 46 channels in the FOV; Body 30
+ Spine 72: - up to 66 channels
in one FOV
Breast Sentinelle 8 elements, Speeder Sentinelle 8 elements, Speeder Sentinelle Speeder or Invivo Optional, 7, 7, RAPID Optional, 7, 7, RAPID Options: dedicated 16ch Options: dedicated 16ch Options: dedicated 16ch Options: dedicated 16ch Options: dedicated 16ch Options: dedicated 16ch Optional 7 Channel Breast Optional, 7 element biopsy Optional, 7 element, 16 Optional, 7 element, 16 Optional, 7 element, 16 Optional, 7 element, 16 element N/A Breast 7 channnel; Sentinelle Breast 7 channnel; Sentinelle Breast 7 channnel; Sentinelle Breast 7 channnel; Sentinelle Breast 7 channnel; Sentinelle
CX breast coil 8 element both CX breast coil 8 element both Speeder, optional, 8 breast; dedicated 8ch breast. breast; dedicated 8ch breast; dedicated 8ch breast; dedicated 8ch breast; dedicated 8ch breast. breast; dedicated 8ch compatible, 16 element element adaptable, biopsy element adaptable, biopsy element adaptable, biopsy adaptable, biopsy compatible, Breast 8 channel with 2- and 4- Breast 8 channel with 2- and 4- Breast 8 channel with 2- and 4- Breast 8 channel with 2- and 4- Breast 8 channel with 2- and 4-
parallel imaging capable, parallel imaging capable, elements, 8 RF, parallel All parallel imaging breast. All parallel imaging breast. All parallel breast. All parallel All parallel imaging breast. All parallel diagnostic, feet first, dS- compatible, feet first, dS- compatible, feet first, dS- compatible, feet first, dS-Sense feet first, dS-Sense channel configs; Sentinelle channel configs; Sentinelle channel configs; Sentinelle channel configs; Sentinelle channel configs; Sentinelle
optional optional imaging capable compatible compatible imaging compatible imaging compatible compatible imaging compatible Sense Sense Sense Breast 16 channel; Breast 18 Breast 16 channel; Breast 18 Breast 16 channel; Breast 18 Breast 16 channel; Breast 18 Breast 16 channel; Breast 18
channel channel channel channel channel
Wrist Wrist Speeder, 6 elements, Wrist Speeder, 6 elements, Wrist Speeder, optional, 6 Optional, 7, 7, RAPID Optional, 3, 3, RAPID Options: 16ch T/R hand- Options: 16ch T/R hand- Options: 16ch T/R hand- Options: 16ch T/R hand- Options: 16ch T/R hand-wrist; Options: 16ch T/R hand- dS MSK 16 Breeze Coil Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS-SENSE Optional 16 Channel dS-SENSE Contour S coil - 6 channels Hand/Wrist 16 - 16 elements; Hand/Wrist 16 - 16 elements; Hand/Wrist 16 - 16 elements; Hand/Wrist 16 - 16 elements; Hand / Wrist 16; Flex Large 4
parallel imaging, optional parallel imaging, optional elements, parallel imaging wrist; Air 20ch MP array; wrist; Air 20ch MP array; wrist; Air 20ch MP array; wrist; Air 20ch MP array; Air 20ch MP array; 16ch flex wrist; Air 20ch MP array; SENSE SENSE SENSE Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; Ultraflex 18 large - 18 channels; and Flex Small 4
capable 16ch flex array. All parallel 16ch flex array. All parallel 16ch flex array. All 16ch flex array. All array. All parallel imaging 16ch flex array (requires Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels Ultraflex 18 small - 18 channels
imaging compatible imaging compatible parallel imaging parallel imaging compatible 49chs). All parallel
compatible compatible imaging compatible
Neurovascular Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Atlas Speeder head/neck, 16 Optional, 22, 15, RAPID Standard 20,16, RAPID HNU up to 61ch when HNU up to 50ch when HNU up to 45ch when HNU up to 49ch when HNU up to 28ch when HNU up to 32ch when Standard 15, digitization in Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, Standard 20, digital coil, channel Head/Neck Coil - 12 channels Head/Neck 16 + Spine 24 RS + Head/Neck 16 + Spine 24 RS + BioMatrix Head/Neck 16 coil - BioMatrix Head/Neck 16 coil - Head/Neck 20 coil -
elements, parallel imaging elements, parallel imaging elements, parallel imaging combined with Air PA and Air combined with GEM PA combined with TDI PA combined with TDI PA combined with GEM PA and combined with TDI PA head coil, dS-Sense, Breeze channel independent, dS- channel independent, dS- channel independent, dS- channel independent, dS-Sense independent, dS-Sense Body 12: - up to 30 channels in Body 12: - up to 30 channels in 16 channels (neck part 4 16 channels (neck part 4 20 channels (neck part 4
capable capable capable 30ch AA; 48ch brain coil and Air AA; 48ch brain coil and Air MP; 48ch brain and 16ch Flex array; TDI AA. All parallel imaging and TDI AA. All parallel S or M Sense Sense Sense the FoV; BioMatrix Head/Neck the FoV; BioMatrix Head/Neck channels); BioMatrix Head/Neck channels; BioMatrix Head/Neck channels; BioMatrix Head/Neck
option. All parallel imaging option. All parallel imaging coil option. All parallel 48ch brain coil option. compatible imaging compatible 20 + Spine 24 RS + Body 12: - up 20 + Spine 32 (or 48) RS + Body 20 coil - 20 channels (neck part 20 coil - 20 channels (neck part 64 coil - 64 channels (neck part
compatible compatible imaging compatible All parallel imaging to 34 channels in the FoV 18: up to 40 channels in the FoV 4 channels) - BioMatrix CoilShim 4 channels) - BioMatrix 9 channels)
compatible CoilShim; BioMatrix Head/Neck
64 coil - 64 channels (neck part
9 channels) - BioMatrix CoilShim
Peripheral vascular Atlas body Speeder +Atlas Atlas body Speeder +Atlas Atlas body Speeder +Atlas Optional 16, 8 to 12 with Optional, 16, 16, RAPID Options: Perivascular array Options: Perivascular array Options: Perivascular Options: Perivascular Options: Perivascular array Options: Perivascular Optional dS TotalBody 91 Optional 108 Channel dS- Optional 108 Channel dS- Optional 108 Channel dS- Optional 108 Channel dS- Optional 108 Channel dS-SENSE N/A Body 18 with spine coils; Body 18 with spine coils; Body 18 with spine coils; Body 18 with spine coils; Body 18 with spine coils;
Speeder spine, 16 elements + 32 Speeder spine, 16 elements + 32 Speeder spine, standard, 16 torso and spine coil, with 49ch when combined with 36ch when combined array with 36ch when array with 36ch when with 35ch when combined array with 39ch when channel SENSE SENSE SENSE SENSE Ultraflex 18 large with spine Peripheral Angio 16; Peripheral Ultraflex 18 large with spine Peripheral angio 36 typically Peripheral angio 36 typically
elements, parallel imaging, elements, parallel imaging, elements + 40 elements, RAPID with Air PA; Air 30ch AA. All with GEM PA; Air 30ch AA. combined with TDI PA; combined with TDI PA; with GEM PA; Air 30ch AA; Air combined with TDI PA; Air coils; Peripheral Angio 16 / 36 angio; 36 typically combined coils combined with head/neck, body, combined with head/neck,
optional optional parallel imaging capable parallel imaging compatible All parallel imaging Air 30ch AA. All parallel Air 30ch AA. All parallel 16ch AA. All parallel imaging 16ch AA. All parallel with head/neck, body, spine or spine or flex coils ultraflex 18 body, spine or flex coils with
compatible imaging compatible imaging compatible compatible imaging compatible flex coils; ultraflex 18 large with large with spine coils spine coils
spine coils
Foot/ankle 8 element dedicated knee/foot 8 element dedicated knee/foot 16 Ch Foot/ankle Speeder Optional 8, 8, RAPID Optional, 7, 7, RAPID Options: 8ch foot-ankle; Air Options: 8ch foot-ankle; Air Options: 8ch foot-ankle; Options: 8ch foot-ankle; Options: 8ch foot-ankle; Air Options: 8ch foot-ankle; dS MSK 16 Breeze Coil Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS- Optional 16 Channel dS-SENSE Optional 16 Channel dS-SENSE 1 x Contour S coil (6ch); 2 x Contour Flex large 4 channel; Flex small Flex large 4 channel; Flex small Flex large 4 channel; Flex small Flex large 4 channel; Flex small Flex large 4 channel; Flex small
Speeder coil or 16 element flex, Speeder coil or 16 element flex, coil or 16 element flex, both 20ch MP array; 16ch flex 20ch MP array; 16ch flex Air 20ch MP array; 16ch Air 20ch MP array; 16ch 20ch MP array; 16ch flex Air 20ch MP array SENSE SENSE SENSE S coils (12ch); 1 x Contour M coil 4 channel; Foot/ankle 16 4 channel; Foot/ankle 16 4 channel; Foot/ankle 16 4 channel; Foot/ankle 16 4 channel; Foot/ankle 16
both with parallel imaging, both with parallel imaging, with parallel imaging, array. All parallel imaging array. All parallel imaging flex array. All parallel flex array. All parallel array. All parallel imaging (requires 49chs); 16ch (12ch) channel; Ultraflex 18 channel channel; Ultraflex 18 channel channel; Ultraflex 18 channel channel; Ultraflex 18 channel channel
optional optional optional compatible compatible imaging compatible imaging compatible compatible flex array. All parallel large large large large
imaging compatible
Others Flex Speeder medium/large, 16 Flex Speeder medium/large, 16 Flex Speeder 4 ch, 16 ch Flex Extremity Std 4, 4 Solenoid general Air Technology: Air 30ch AA, Air Technology: Air 30ch Air Technology: Air 30ch Air Technology: Air 30ch Air Technology: Air 30ch AA, Air Technology: Air 16ch Optional TotalBody 91 Optional Flex S/4, M/6, and Optional Flex S/4, M/6, and Optional Flex S/4, M/6, and Optional Flex S/4, M/6, and L/8 Optional Flex S/4, M/6, and L/8 N/S Loop large/medium/small (opt, Loop large/medium/small (opt, Loop large/medium/small (opt, Loop large/medium/small (opt, Sentinelle and NORAS breast
and 4 elements coils, parallel and 4 elements coils, parallel medium, 16 ch large 16, RAPID; micro opt 1, 1, No purpose:standard, 1, 1, no; Air 21ch MP array, Air 20ch AA, Air 21ch MP array, Air AA, Air 21ch MP array, AA, Air 21ch MP array, Air 16ch AA, Air 21ch MP AA, Air 21ch MP array channel L/8 Channel Coils L/8 Channel Coils L/8 Channel Coils, Channel Coils, MultiNuclei Channel Coils, MultiNuclei Coils 1 e, 1 ch, iPAT-compatible with 1 e, 1 ch, iPAT-compatible with 1 e, 1 ch, iPAT-compatible with 1 e, 1 ch, iPAT-compatible with coils
imaging capable, Shape Coil imaging capable, Shape Coil parallel imaging capable, micro coil: Optional, 1,1, MP array. All parallel imaging 20ch MP array. All parallel Air 20ch MP array. All Air 20ch MP array. All array, Air 20ch MP array. All (requires 49chs), Air 20ch MultiNuclei Coils Coils other coils); Medrad endorectal other coils); Medrad endorectal other coils); Medrad endorectal other coils); Medrad endorectal
16/32 optional 16/32 optional Shape coil 16/32, optional No compatible imaging compatible parallel imaging parallel imaging parallel imaging compatible MP array (requires coil kit (opt, iPAT-compatible coil kit (opt, iPAT-compatible coil kit (opt, iPAT-compatible coil kit (opt, iPAT-compatible
compatible compatible 49chs). All parallel with other coils) with other coils) with other coils) with other coils)
imaging compatible
Imaging Features
Non-contrast Fresh blood imaging (FBI), Fresh blood imaging (FBI), Fresh blood imaging (FBI), VASC-ASL; VASC-FSE; VASC-ASL; VASC-FSE; 2D/3D TOF, 2D/3D Phase 2D/3D TOF, 2D/3D Phase 2D/3D TOF, 2D/3D 2D/3D TOF, 2D/3D 2D/3D TOF, 2D/3D Phase 2D/3D TOF, 2D/3D Phase Yes, 3D IC72:C83nflow, 2D Yes, 3D IC72:C83nflow, 2D Yes, 3D IC72:C83nflow, 2D Yes, 3D IC72:C83nflow, 2D Yes, 3D IC72:C83nflow, 2D Yes, 3D IC72:C83nflow, 2D No Yes Yes Yes Yes Yes
angiography contrast-free improved contrast-free improved contrast-free improved BeamSat TOF, BeamSat BeamSat TOF, BeamSat Contrast, Inhance Suite Contrast, Inhance Suite Phase Contrast, Inhance Phase Contrast, Inhance Contrast, Inhance Suite Contrast, Inhance Suite Inflow, 4D PCA, Trance, Stir Inflow, 4D PCA, Trance, Stir Inflow, 4D PCA, Trance, Stir Inflow, 4D PCA, Trance, Stir Inflow, 4D PCA, Trance, Stir Inflow, 4D PCA, Trance, Stir
angiography (CIA), time-SLIP: angiography (CIA), time-SLIP: angiography (CIA), time- VASC-ASL; blood VASC-ASL; blood sensitive option, 3D ASL option, Cube option, 3D ASL option, Suite option, 3D ASL Suite option, 3D ASL option, 3D ASL option, Cube option, 3D ASL option, Trance, React, Bass-Trance, Trance, React, Bass-Trance, Trance, React, Bass-Trance, Trance, React, Bass-Trance, Trance, React, Bass-Trance, 2D Trance, React, Bass-Trance, 2D
spatial labeling inversion pulse, spatial labeling inversion pulse, SLIP: spatial labeling sensitive imaging; imaging; RADAR-TOF MSDE option Cube MSDE option option, Cube MSDE option, Cube MSDE MSDE option Cube MSDE option 2D PCA, 3D B-TFE 2D PCA, 3D B-TFE 2D PCA, 3D B-TFE 2D PCA, 3D B-TFE PCA, 3D B-TFE PCA, 3D B-TFE
time space angiography (TSA), time space angiography (TSA), inversion pulse, time space RADAR-TOF option option
FSBB, mASTAR mUTE MRA FSBB, mASTAR mUTE MRA angiography (TSA), FSBB,
mASTAR mUTE MRA
Plaque imaging No No No SIR Map with RADAR-SE SIR Map with RADAR-SE READYView, MR VesselIQ READYView, MR VesselIQ READYView, MR READYView, MR READYView, MR VesselIQ READYView, MR VesselIQ Yes, with Compressed Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense No Yes Yes Yes Yes Yes
and color analysis (T1WI) (T1WI) option, Cube MSDE option option, Cube MSDE option VesselIQ option, Cube VesselIQ option, Cube option, Cube MSDE option option, Cube MSDE Sense
MSDE option MSDE option option
Selective MRA with Yes Yes Yes BeamSat TOF (neuro) N/A Inhance Suite option Inhance Suite option Inhance Suite option Inhance Suite option Inhance Suite option Inhance Suite option Yes, with Compressed Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense Yes, with Compressed Sense Yes Yes Yes Yes Yes Yes
cylindrical-shaped and BeamSat VASC-ASL Sense
saturation (body)
Spectroscopy Single and multi-voxel Single and multi-voxel Single and multi-voxel Chemical shift imaging Single or dual voxel Probe Press, Probe Steam Probe Press, Probe Steam Probe Press, Probe Probe Press, Probe Probe Press, Probe Steam Probe Press, Probe Yes, Single VoXel, Multi Yes, Single VoXel, Multi Yes, Single VoXel, Multi Yes, Single VoXel, Multi Voxel Yes, Single VoXel, Multi Voxel Yes, Single VoXel, Multi Voxel 2D No Yes (including multinuclear Yes (including multinuclear Yes (including multinuclear Yes (including multinuclear Yes (including multinuclear
(multi-voxel) and single option, 2D CSI option, 3D CSI option, 2D CSI option, 3D Steam option, 2D CSI Steam option, 2D CSI option, 2D CSI option, 3D CSI Steam option, 2D CSI Voxel 2D and 3D Voxel 2D and 3D Voxel 2D and 3D 2D and 3D 2D and 3D and 3D option) option) option) option) option)
or dual voxel option, Brease option CSI option, Brease option option, 3D CSI option, option, 3D CSI option, option, Brease option, Prose option, 3D CSI option,
Brease option Brease option option Brease option, Prose
option
Motion JET JET JET RADAR - SE, FSE, GE, RADAR - SE, FSE, GE, TOF Propeller MB (compatible Propeller MB (compatible Propeller MB Propeller MB Propeller MB (compatible Propeller MB (compatible Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Compressed Yes Yes Yes Yes Yes Yes
compensating DWI, TOF with Air Recon DL option); with Air Recon DL option); (compatible with Air (compatible with Air with Air Recon DL option); with Air Recon DL option); Compressed SENSE Compressed SENSE Compressed SENSE Compressed SENSE Compressed SENSE SENSE
radial techniques Disco Star option Disco Star option Recon DL option); Disco Recon DL option); Disco Disco Star option Disco Star option
Star option Star option
Motion N/A N/A N/A RAPID-RADAR RADAR Propeller MB; Disco Star Propeller MB; Disco Star Propeller MB; Disco Star Propeller MB; Disco Star Propeller MB; Disco Star Propeller MB; Disco Star Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Yes, 2D, 3D, 4D with Compressed Yes Yes Yes Yes Yes Yes
compensating option option option option option option Compressed SENSE Compressed SENSE Compressed SENSE Compressed SENSE Compressed SENSE SENSE
radial techniques
with parallel
imaging for all
regions
Brain volume Yes Yes Yes isoFSE / 3DGEIR isoFSE / 3DGEIR 3D Bravo, 3D MP Rage, 3D 3D Bravo, 3D MP Rage, 3D 3D Bravo, 3D MP Rage, 3D Bravo, 3D MP Rage, 3D Bravo, 3D MP Rage, 3D 3D Bravo, 3D MP Rage, Yes, 3-D BrainView with Yes, 3-D BrainView with Yes, 3-D BrainView with Yes, 3-D BrainView with Yes, 3-D BrainView with Yes, 3-D BrainView with Yes Yes Yes Yes Yes Yes
Imaging Cube, 3D Cube DIR, 3D Cube, 3D Cube DIR, 3D 3D Cube, 3D Cube DIR, 3D Cube, 3D Cube DIR, Cube, 3D Cube DIR, 3D Promo 3D Cube, 3D Cube DIR, 3D Compressed Sense Compressed Sense and Compressed Sense and Compressed Sense and Compressed Sense and Compressed Sense and
Promo option Promo option 3D Promo option 3D Promo option option Promo option SmartSpeed AI SmartSpeed AI SmartSpeed AI SmartSpeed AI SmartSpeed AI
Ultra-short TE (TE Yes Yes Yes uTE (TE min 0.25ms) uTE (TE min 0.25ms) 3D Silenz option, 3D Silenz 3D Silenz option, 3D Silenz 3D Silenz option, 3D 3D Silenz option, 3D 3D Silenz option, 3D Silenz 3D Silenz option, 3D 2D FFE 0.28ms 2D FFE 0.28ms 2D FFE 0.22ms 2D FFE 0.22ms 2D FFE 0.21ms 2D FFE 0.20ms No Yes Yes Yes Yes Yes
< 1ms, multi- MRA option, 3D oZTEo MRA option, 3D oZTEo Silenz MRA option, 3D Silenz MRA option, 3D MRA option, 3D oZTEo Silenz MRA option, 3D
slice) option. Air Recon DL and option. Air Recon DL and oZTEo option. Air Recon oZTEo option. Air Recon option. Air Recon DL and oZTEo option. Air Recon
HyperWorks acceleration HyperWorks acceleration DL and HyperWorks DL and HyperWorks HyperWorks acceleration DL and HyperWorks
options options acceleration options acceleration options options acceleration options
Minimum 1.0 ms STD 1.0 ms, XGO 0.8 ms Standard 2.4 ms, XGO: 1.4 1.4 0.67 msec at 128 x 128 full 0.68 msec at 128 x 128 full 0.75 msec at 128 x 128 0.75 msec at 128 x 128 0.668 msec at 128 x 128 full 0.705 msec at 128 x 128 0.8ms 0.8ms 0.8ms 0.8ms 0.8ms 0.8ms 2.9 ms (256 matrix) 1.14 ms (256 matrix) 0.97 ms (256 matrix) 1.07 ms (256 matrix) 1.07 ms (256 matrix) 0.98 (256 matrix)
repetition time (3-D 2.0ms FOV FOV full FOV full FOV FOV full FOV
T1 spoiled gradient
echo), msec
Minimum echo STD 0.29 ms, XGO 0.24 ms STD 0.29 ms, XGO 0.24 ms 0.9 ms 0.6 0.6 0.184 msec at 128 x 128 full 0.176 msec at 128 x 128 0.216 msec at 128 x 0.216 msec at 128 x 0.184 msec at 128 x 128 full 0.2 msed at 128 x 128 full 0.24ms 0.24ms 0.18ms 0.18ms 0.18ms 0.17ms 1.24 ms (256 matrix) 0.28 ms (256 matrix) 0.22 ms (256 matrix) 0.22 ms (256 matrix) 0.22 ms (256 matrix) 0.18 ms (256 matrix)
time, (3-D T1 FOV full FOV 128 full FOV 128 full FOV FOV FOV
spoiled gradient
echo), msec
FOV (AP, RL, HF, 0.5 x 0.5 x 0.5 cm min FOV, 55 x 0.5 x 0.5 x 0.5 cm min FOV, 55 x 0.5 x 0.5 x 0.5 cm min FOV, 50, 50, 50, 0.5 - 50 45, 45, 45, 5-45 50 x 50 x 50 cm 50 x 50 x 50 cm 50 x 50 x 50 cm 50 x 50 x 48 cm 55 cm x 55 cm x 50 cm 50 cm x 50 cm x 50 cm 55 x 55 x 50 55 x 55 x 50 55 x 55 x 50 55 x 55 x 50 55 x 55 x 50 55 x 55 x 50 0.5 - 50 cm 0.5 - 50 cm 0.5 - 50 cm 0.5 - 55 cm 0.5 - 55 cm 0.5 - 50 cm
Min to Max), cm 55 x 50 cm max FOV 55 x 50 cm max FOV 50 x 50 x 45 cm max FOV
Power
Requirements
Voltage (line, 380/400/415/440/480 V / 3 380/400/415/440/480 V / 3 400V / 3 phase 460/480 3-phase 480 3-phase 3 phase, 450/415/380/Vrms 3 phase, 450/415/380/ 3 phase, 450/415/380/ 3 phase, 450/415/380/ 3 phase, 450/415/380/Vrms 3 phase, 450/415/380/ 400/480 3 phase 400/480 3 phase 400/480 3 phase 400/480 3 phase 400/480 3 phase 400/480 3 phase 380 / 400 / 440 / 480 V, 3 phase + 380 / 400 / 420 / 440 / 460 / 380 / 400 / 420 / 440 / 460 / 380 / 400 / 420 / 440 / 460 / 380 / 400 / 420 / 440 / 460 / 380 / 400 / 420 / 440 / 460 /
voltage, phases) phase phase Vrms Vrms Vrms Vrms ground 480 V, 3 phase + ground 480 V, 3 phase + ground 480 V, 3 phase + ground 480 V, 3 phase + ground 480 V, 3 phase + ground
kVA 52 kVA STD 52kVA, XGO 80 kVA 70 kVA, 90 kVA 100 75 Less than 17 kVA standby; 99 Less than 17 kVA standby; Less than 6.4 kW sleep Less than 6.4 kW sleep Less than 17 kVA standby; 99 Less than 5.7 kW sleep Stand-by 6.9 kW; Ready to Stand-by 6.9 kW; Ready to Stand-by 6.9 kW; Ready to Stand-by 7.0 kW; Ready to Stand-by 7.0 kW; Ready to scan Stand-by 7.0 kW; Ready to scan 47 kVA XK gradients: 84 kVA XQ gradients: 84 kVA; XT XJ gradients: 69 kVA XJ gradients: 69 kVA; XQ XR gradients: 94 kVA
kVA maximum continuous 99 kVA maximum mode; 64 kVA maximum mode; 64 kVA maximum kVA maximum continuous mode; 64 kVA maximum scan 10.2 kW; Scanning scan 10.2 kW; Scanning 16.9 scan 10.6 kW; Scanning 22.2 scan 13.0 kW; Scanning 22.8 13.0 kW; Scanning 22.8 kW 13.0 kW; Scanning 22.8 kW gradients: 118 kVA gradients: 88 kVA
sustained power; at least 195 continuous sustained continuous sustained continuous sustained sustained power continuous sustained 16.9 kW kW kW kW
kVA peak instanteous power; at least 123 kVA power; at least 77 kVA power; at least 77 kVA power; at least 77 kVA
peak instanteous peak instanteous peak instanteous peak instanteous
A/C, BTU/hr (for Approx: STD 21,000, STD w GAC Approx: STD 21,000, STD w GAC Approx: STD 37,000, XGO: 63,535 BTU/hr 51,740 BTU/hr 15-21 degrees C in magnet 15-21 degrees C in magnet 15-21 degrees C in 15-21 degrees C in 15-21 degrees C in magnet 15-21 degrees C in N/S N/S N/S N/S N/S N/S N/S 10,236 BTU/hr (exam room), 10,236 BTU/hr (exam room), 10,236 BTU/hr (exam room), 10,236 BTU/hr (exam room), 10,236 BTU/hr (exam room),
entire system) 6900 6900, XGO 6900 BTU/Hr 43,000 BTU/hr room; 15-32 degrees C in room; 15-32 degrees C in magnet room; 15-32 magnet room; 15-32 room; 15-32 degrees C in magnet room; 15-32 3,412 BTU/hr (equipment room) 3,412 BTU/hr (equipment room) 3,412 BTU/hr (equipment room) 3,412 BTU/hr (equipment room) 3,412 BTU/hr (equipment room)
control and equipment room control and equipment degrees C in control and degrees C in control and control and equipment room degrees C in control and
room equipment room equipment room equipment room
Website https://us.medical.canon/ https://us.medical.canon/ https://us.medical.canon/ https://hca.fujifilm.com/ https://hca.fujifilm.com/ https://www.siemens- https://www.siemens- https://www.siemens- https://www.siemens- https://www.siemens- https://www.siemens-
healthineers.com/en-us/magnetic- healthineers.com/en-us/ healthineers.com/en-us/ healthineers.com/en-us/ healthineers.com/en-us/ healthineers.com/en-us/
resonance-imaging magnetic-resonance-imaging magnetic-resonance-imaging magnetic-resonance-imaging magnetic-resonance-imaging magnetic-resonance-imaging