D) CHECK FOR SHEAR : ( IRC 112 / clause 10.3.

2 (2) )

Check of Shear Reinforcement Requirement

r1 = Min [ Asl/bw

3/2
VRdc =Max [ ( 0.12 k

nmin = 0.031 k
Ö200/d , 2 ]
k= Min [ 1 +
(80 r1 fck )0.33 + 0.15

d , 0.02 ]
scp ) bw d , (nmin

1/2
VED bVED scp

fck
Load comb. b d bw Asl +0.15scp ) bw d ] Check
T T mm mm mm2 Mpa Tonne
Provide shear reinf.
ULS 1003.8 5100 5119242 1715 5100 1.341 12324.71 0.001 0.305 3.576 735.61

Check for Maximum Shear Capacity :

Vrdmax = acw
q = 0.5 sin-1 [ 2*VNS

f adopted
n1 * fcd /2
* bw * z *
/ (acw * bw * z * v1 *
fcd) ]
Load comb. VED bw d z =0.9d acw n1 Check
T mm mm mm Tonne deg deg

ULS 1003.8 5100 1715 1543.5 1 0.6 4222 OK 6.88 26.5

FINDING DESIGN SHEAR REINFORCEMENT REQUIREMENT


rw,min =( 0.072

DFd = 0.5 VED


rw,min*s *bw
√ fck ) / fyk

Asw/s = VED / z fywd Provide Asw

provide
Asw/s
Load comb. VED bw z qdesign
Asw,min =

cotq Check

cotq
Legs dia spacing
2 2
T mm mm deg mm /m mm /m nos mm mm mm2/m T

ULS 1003.8 5100 1543.5 45 11824.05 0.000828 548.9254 501.9