Selfweight :
In midas civil, self-weight is applied in the analysis model using the self-weight
command and having option to change the intensity of self-weight using selfweight
multiplier. Self weight is calculated based on section properties and material density
data given in the model.
2
Construction Stage Live Load = 0.15 t/m
CSLL UDL on Outer Girder = 0.604 t/m
CSLL UDL on Inner Girder = 0.555 t/m
11.75
0.5 0 10.75 0 0.5
53 mm thick WC
2
Wearing coat = 0.2 t/m
Wearing coat UDL on Outer Girder = 0.705 t/m
Wearing coat UDL on Inner Girder = 0.74 t/m
0.00
Footpath weight = 0.000 t/m
2
= 0.000 t/m 0.35
2
Footpath Live load = 0.500 t/m
= 0.000 t/m