Dead load
Length Support s = 6000 mm
Wide Support l = 3000 mm
Diameter of Pipe Out side Diameter D = 168 mm
Density of Steel rho = 7850 Kg/m3
Wall Thicness t = 4.8 mm

Weight total of Pipe π*D*t*rho DL = 119.26 Kg


Koefisien Impack 1.2 = 143.11 Kg

Weight of bondex 0.7 t = 7 Kg/m2


Floor Load Uniform force one way = 0.07 KN
= 7.0 Kg m
Live Load
Worker Load = 100 Kg
= 0.98 KN

Equipment (pipe) uniform = 95.41 Kg m


Equipment (tools) uniform Asumtion = 40.00 Kg m
Total Equipmen uniform = 135.41 Kg m
= 1.33 KN

Total Live Load = 2.31 KN


LOAD IS TEMPORARY SUPPORT
Dead load
Distance Support s = 3000 mm
Diameter of Pipe D = 150 mm
Density of Steel rho = 8000 Kg/m3
Wall Thicness t = 6 mm
Gravity g = 9.81 m/s2

Weight total of Pipe π*D*t*rho*g DL = 67.82 Kg


KN
KN

Media (Live Load)


Density of Water rho = 1000 Kg/m3

Weight total of Media 1/4π*D2*s*rho water LL = 52.99 Kg


KN
Distributed in 2 support Concentrate Force KN
Uniform force

52.99 Kg

519.81 N
Asumsi
66.55 Kg

0.009807

0.001

0.052988 M3
52.9875
448976.23