You are on page 1of 2

1.

Dead Load (DL)


Selfweight of structure are defined automatically by StaadPro

2. Piping Load (P)

Pipe = DN1000
Sch = STD
Outer dia. do = 1016 mm
wall thickness t = 9.53 mm
Inner dia. di = 996.94 mm

area of inside pipe Am = p x di^2 / 4 = 0.781 m2

Weight of empty pipes Wp = ρm x π x (do^2 - di^2) / 4 = 236.54 kg/m


Density of water : = 1000 kg/m3
Weight of full water in pipes Wl = ρi x Am = 780.60 kg/m
Weight pipe include water Wtot = Wp + Wl = 1017.14 kg/m

Pipe = DN700
Sch = STD
Outer dia. do = 711 mm
wall thickness t = 9.53 mm
Inner dia. di = 691.94 mm

area of inside pipe Am = p x di^2 / 4 = 0.376 m2

Weight of empty pipes Wp = ρm x π x (do^2 - di^2) / 4 = 164.86 kg/m


Density of slurry : = 1220 kg/m3
Weight of slurry in pipes Wl = ρi x Am = 458.76 kg/m
Weight pipe include slurry Wtot = Wp + Wl = 623.62 kg/m
Empty Condition (PE)
Weight Tributary Load load
Location Pipe Fluide
(kg/m) (m) (kg) (kN/m)
DN700 - 164.86 6 989.1742 9.701
DN1000 - 236.54 6 1419.268 13.918
Level 1
DN700 - 164.86 6 989.1742 9.701
Subtotal 566.27 3397.62 33.32
DN700 - 164.86 6 989.1742 9.701
DN1000 - 236.54 6 1419.268 13.918
Level 2
DN700 - 164.86 6 989.1742 9.701
Subtotal 566.27 3397.62 33.32
DN700 - 164.86 6 989.1742 9.701
DN1000 - 236.54 6 1419.268 13.918
Level 3
DN700 - 164.86 6 989.1742 9.701
Subtotal 566.27 3397.62 33.32

Operating & Testing Condition (PO & PT)


Weight Tributary Load load
Location Pipe Fluide
(kg/m) (m) (kg) (kN/m)
DN700 Slurry 623.62 6 3741.74 36.695
DN1000 Water 1017.14 6 6102.86 59.850
Level 1
DN700 Slurry 623.62 6 3741.74 36.695
Subtotal 2264.39 13586.34 133.24
DN700 Slurry 623.62 6 3741.74 36.695
DN1000 Water 1017.14 6 6102.86 59.850
Level 2
DN700 Slurry 623.62 6 3741.74 36.695
Subtotal 2264.39 13586.34 133.24
691.94 Slurry 623.62 6 3741.74 36.695
DN1000 Water 1017.14 6 6102.86 59.850
Level 3
691.94 Slurry 623.62 6 3741.74 36.695
Subtotal 2264.39 13586.34 133.24

3. Pipe Friction Load (FF)


Pipe friction force to structure be considered as table below :
Friction coefficient steel to steel fr = 0.2

equation : Tz = F x fr

horizontal longitudinal force


Load Tz Tz
Location Pipe Fluide
(kg/m) (kg/m) (kN/m)
DN700 Slurry 3741.74 748.3482 7.339
DN1000 Water 6102.86 1220.572 11.970
Level 1
DN700 Slurry 3741.74 748.3482 7.339
Subtotal 13586.34 2717.27 26.65
DN700 Slurry 3741.74 748.3482 7.339
DN1000 Water 6102.86 1220.572 11.970
Level 2
DN700 Slurry 3741.74 748.3482 7.339
Subtotal 13586.34 2717.27 26.65
DN700 Slurry 3741.74 748.3482 7.339
DN1000 Water 6102.86 1220.572 11.970
Level 3
DN700 Slurry 3741.74 748.3482 7.339
Subtotal 13586.34 2717.27 26.65