No of cylinders : 6 in line
Since our products are in continuous development, we reserve the right to make technical modifications.
Page 2
Natural Gas Engine E 2876 E 312 03 / 2011
Technical Data
ENGINE DATA 50 Hz 50 Hz
λ = 1.00 METRIC ENGLISH
Rated speed rpm 1500 rpm 1500
ISO standard power (COP) kW 150 bhp 201
Air ratio λ 1.00 λ 1.00
Lube oil to MAN works standard M 3271-2 and coolant to MAN works standard M 324 Type NF
Gas quality to MAN data sheet - minimum requirement for the gas quality for MAN gas engines
Air ratio measured by lambdameter ETAS LA 4_E
Page 3
Natural Gas Engine E 2876 E 312 03 / 2011
Technical Data
RATING DATA 50 Hz
λ = 1.00 METRIC
Load % 100 75 50
Ignition timing °BTDC 18 18 18
ISO standard rating kW 150 113 75
Coolant heat kW 128 108 86
Exhaust heat up to 120 °C kW 79 63 44
Radiation heat max. kW 18
Energy input kW 392 311 227
Efficiency
mechanical % 38,4 36,2 33,0
thermal % 52,8 54,9 57,2
total % 91,2 91,1 90,3
Mass flows
Combustion air kg/h 475 385 282
Fuel kg/h 29 23 17
Exhaust gas mass flow rate, wet kg/h 503 408 298
Temperatures
Exhaust gas temperature °C 590 580 570
Reference gas mixing unit: RMG 985a-100/90 and ignition system IC 100
The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 80
The technical data indicated is based on standard conditions acc to DIN ISO 3046-1
Standard conditions: Atmospheric pressure absolute: 100 kPa
Air temperature 25 °C
Relative air humidity 30 %
Rating adaptation at ambient conditions acc to DIN ISO 3046-1
The tolerance for the specific fuel consumption is + 5 % at rated output
The tolerance for the usable heat is 7 % at rated output
The coolant data are based on a 40 % portion of antifreeze
Page 4
Natural Gas Engine E 2876 E 312 03 / 2011
Technical Data
RATING DATA 50 Hz
λ = 1.00 ENGLISH
Load % 100 75 50
Ignition timing °BTDC 18 18 18
ISO standard rating Btu/min 8530 6398 4265
Coolant heat Btu/min 7279 6142 4891
Exhaust heat up to 248 °F Btu/min 4483 3559 2502
Radiation heat max. Btu/min 1024
Energy input Btu/min 22274 17665 12914
Efficiency
mechanical % 38,4 36,2 33,0
thermal % 52,8 54,9 57,2
total % 91,2 91,1 90,3
Mass flows
Combustion air lb/hr 1046 850 621
Fuel lb/hr 63 50 37
Exhaust gas mass flow rate, wet lb/hr 1109 900 658
Temperatures
Exhaust gas temperature °F 1094 1076 1058
Reference gas mixing unit: RMG 985a-100/90 and ignition system IC 100
The technical data are based on natural gas with a calorific value of 970 Btu/cu ft and a methane no. > 80
The technical data indicated is based on standard conditions acc to DIN ISO 3046-1
Standard conditions: Atmospheric pressure: 14,5 psi or 328 ft above sea level
Air temperature 77 °F
Relative air humidity 30 %
Rating adaptation at ambient conditions acc to DIN ISO 3046-1
The tolerance for the specific fuel consumption is + 5 % at rated output
The tolerance for the usable heat is 7 % at rated output
The coolant data are based on a 40 % portion of antifreeze
Page 5
Natural Gas Engine E 2876 E 312 03 / 2011
Preliminary Technical Data
ENGINE DATA 60 Hz 60 Hz
λ = 1.00 METRIC ENGLISH
Rated speed rpm 1800 rpm 1800
ISO standard power (COP) kW 170 bhp 228
Air ratio λ 1.00 λ 1.00
Lube oil to MAN works standard M 3271-2 and coolant to MAN works standard M 324 Type NF
Gas quality to MAN data sheet - minimum requirement for the gas quality for MAN gas engines
Air ratio measured by lambdameter ETAS LA 4_E
Page 6
Natural Gas Engine E 2876 E 312 03 / 2011
Preliminary Technical Data
RATING DATA 60 Hz
λ = 1.00 METRIC
Load % 100 75 50
Ignition timing °BTDC 20 20 20
ISO standard rating kW 170 128 85
Coolant heat kW 145 124 100
Exhaust heat up to 120 °C kW 98 76 55
Radiation heat max. kW 18
Energy input kW 449 354 264
Efficiency
mechanical % 38,0 36,0 32,2
thermal % 54,1 56,4 58,5
total % 92,1 92,4 90,7
Mass flows
Combustion air kg/h 544 440 328
Fuel kg/h 33 26 19
Exhaust gas mass flow rate, wet kg/h 576 465 347
Temperatures
Exhaust gas temperature °C 620 610 600
Reference gas mixing unit: RMG 985a-100/90 and ignition system IC 100
The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 80
The technical data indicated is based on standard conditions acc to DIN ISO 3046-1
Standard conditions: Atmospheric pressure absolute: 100 kPa
Air temperature 25 °C
Relative air humidity 30 %
Rating adaptation at ambient conditions acc to DIN ISO 3046-1
The tolerance for the specific fuel consumption is + 5 % at rated output
The tolerance for the usable heat is 7 % at rated output
The coolant data are based on a 40 % portion of antifreeze
Page 7
Natural Gas Engine E 2876 E 312 03 / 2011
Preliminary Technical Data
RATING DATA 60 Hz
λ = 1.00 ENGLISH
Load % 100 75 50
Ignition timing °BTDC 20 20 20
ISO standard rating Btu/min 9668 7251 4834
Coolant heat Btu/min 8246 7040 5687
Exhaust heat up to 248 °F Btu/min 5554 4323 3109
Radiation heat max. Btu/min 1024
Energy input Btu/min 25512 20141 15039
Efficiency
mechanical % 38,0 36,0 32,2
thermal % 54,1 56,4 58,5
total % 92,1 92,4 90,7
Mass flows
Combustion air lb/hr 1198 969 724
Fuel lb/hr 72 57 43
Exhaust gas mass flow rate, wet lb/hr 1271 1026 766
Temperatures
Exhaust gas temperature °F 1148 1130 1112
Reference gas mixing unit: RMG 985a-100/90 and ignition system IC 100
The technical data are based on natural gas with a calorific value of 970 Btu/cu ft and a methane no. > 80
The technical data indicated is based on standard conditions acc to DIN ISO 3046-1
Standard conditions: Atmospheric pressure: 14,5 psi or 328 ft above sea level
Air temperature 77 °F
Relative air humidity 30 %
Rating adaptation at ambient conditions acc to DIN ISO 3046-1
The tolerance for the specific fuel consumption is + 5 % at rated output
The tolerance for the usable heat is 7 % at rated output
The coolant data are based on a 40 % portion of antifreeze
Page 8
Natural Gas Engine E 2876 E 312 03 / 2011
METRIC
1,8
1,6
1,4
1,2
Pressure loss (bar)
0,8
0,6
0,4
0,2
0
0 100 200 300 400 500 600
Volume flow (l/min)
Page 9
Natural Gas Engine E 2876 E 312 03 / 2011
ENGLISH
24
22
20
18
16
14
Pressure loss (psi)
12
10
0
0 20 40 60 80 100 120 140 160
Volume flow (U.S. gal/min)