Abstract: This paper is briefly reviewed on types, examples, objective of Biomedical signals , which are observations of physiological
activities of organisms, ranging from gene and protein sequences, to neural and cardiac rhythms, to tissue and organ images.
Biomedical signal processing aims at extracting significant information from biomedical signals. With the aid of biomedical signal
processing, biologists can discover new biology and physicians can monitor distinct illnesses.
The EEG (popularly known as brain waves) represents the The carotid pulse is a pressure signal recorded over the
electrical activity of the brain. A few important aspects of carotid artery as it passes near the surface of the body at
the organization of the brain are as follows: The main parts the neck. It provides a pulse signal indicating the
of the brain are the cerebrum, the cerebellum, the brain variations in arterial blood pressure and volume with each
stem (including the midbrain, pons medulla, and the heart beat. Because of the proximity of the recording site
reticular formation), and the thalamus (between the to the heart, the carotid pulse signal closely resembles the
midbrain and the hemispheres). The cerebrum is divided morphology of the pressure signal at the root of the aorta;
into two hemispheres, separated by a longitudinal fissure however, it cannot be used to measure absolute pressure
across which there is a large connective band of fibers [21].
known as the corpus callosum. The outer surface of the
cerebral hemispheres, known as the cerebral cortex, is 2.10 Signals from catheter-tip sensors
composed of neurons (grey matter) in convoluted patterns,
and separated into regions by fissures (sulci). Beneath the For very specific and close monitoring of cardiac function,
cortex lie nerve fibers that lead to other parts of the brain sensors placed on catheter tips may be inserted into the
and the body [14-16]. cardiac chambers. It then becomes possible to acquire
several signals such as left ventricular pressure, right atrial
2.6 Event-related potentials (ERPs) pressure, aortic pressure, and intra cardiac sounds. While
these signals provide valuable and accurate information,
The term event-related potential is more general than and the procedures are invasive and are associated with certain
preferred to the term evoked potential, and includes the risks [22, 23].
ENG or the EEG in response to light, sound, electrical, or
other external stimuli. Short-latency ERPs are 2.11 The speech signal
predominantly dependent upon the physical characteristics
of the stimulus, whereas longer-latency ERPs are Human beings are social creatures by nature, and have an
predominantly influenced by the conditions of presentation innate need to communicate. We are endowed with the
of the stimuli. most sophisticated vocal system in nature. The speech
signal is an important signal, although it is more
2.7 The Electrogastrogram (EGG) commonly considered as a communication signal than a
biomedical signal. However, the speech signal can serve as
The electrical activity of the stomach consists of rhythmic a diagnostic signal when speech and vocal-tract disorders
waves of depolarization and repolarization of its need to be investigated [25].
constituent smooth muscle cells [17-19]. The activity
originates in the mid-corpus of the stomach, with intervals 2.12 The Vibroarthrogram (VAG)
of about 20 s in humans. The waves of activity are always
present and are not directly associated with contractions; Considerable noise is often associated with degeneration
they are related to the spatial and temporal organization of of knee-joint surfaces. The VAG is the vibration signal
gastric contractions. External (cutaneous) electrodes can recorded from a joint during movement (articulation) of
record the signal known as the electrogastrogram (EGG). the joint. Normal joint surfaces are smooth and produce
Chen et al. [20] used the following procedures to record little or no sound, whereas joints affected by osteoarthritis
cutaneous EGG signals. and other degenerative diseases may have suffered
cartilage loss and produce grinding sounds. Detection of
knee-joint problems via the analysis of VAG signals could
help avoid unnecessary exploratory surgery, and also aid
Volume 11 Issue 5, May 2022
www.ijsr.net
Licensed Under Creative Commons Attribution CC BY
Paper ID: SR22429215651 DOI: 10.21275/SR22429215651 361
International Journal of Science and Research (IJSR)
ISSN: 2319-7064
SJIF (2022): 7.942
better selection of patients who would benefit from Figure 1.1 illustrates the typical steps and processes
surgery. The VAG signal, however, is not yet well involved in computer-aided diagnosis and therapy based
understood, and is a difficult signal to analyse due to its upon biomedical signal analysis.
complex non stationary characteristics [26-32].
The major objectives of biomedical instrumentation and
2.13 Oto-acoustic emission signals signal analysis [10-12] are:
The oto-acoustic emission (OAE) signal represents the Information gathering - measurement of phenomena to
acoustic energy emitted by the cochlea either interpret a system.
spontaneously or in response to an acoustic stimulus. The Diagnosis - detection of malfunction, pathology, or
discovery of the existence of this signal indicates that the abnormality.
cochlea not only receives sound but also produces acoustic Monitoring - obtaining continuous or periodic
energy. The OAE signal could provide objective information about a system.
information on the micromechanical activity of the Therapy and control - modification of the behaviour of
preneural or sensory components of the cochlea that are a system based upon the outcome of the activities listed
distal to the nerve-fiber endings. Analysis of the OAE above to ensure a specific result.
signal could lead to improved noninvasive investigative Evaluation - objective analysis to determine the ability
techniques to study the auditory system. The signal may to meet functional requirements, obtains proof of
also assist in screening of hearing function and in the performance, perform quality control, or quantify the
diagnosis of hearing impairment [33]. effect of treatment.
3.Objectives of Biomedical Signal Analysis Signal acquisition procedures may be categorized as being
invasive or non invasive, and active or passive.
The representation of biomedical signals in electronic form
facilitates computer processing and analysis of the data.
Figure 1.1: Computer-aided diagnosis and therapy based upon biomedical signal analysis
3.1 The human - instrument system: Recording, data processing, and transmission
equipment: analog instrumentation tape recorders,
The components of a human – instrument system [10- analog-to-digital converters (ADCs), digital-to-analog
12] are: converters (DACs), digital tapes, compact disks (CDs),
diskettes, computers, telemetry systems.
The subject or patient: It is important always to bear in Control devices: power supply stabilizers and isolation
mind that the main purpose of biomedical equipment, patient intervention systems.
instrumentation and signal analysis is to provide a
certain benefit to the subject or patient. The science of measurement of physiological variables and
Stimulus or procedure of activity Application of parameters is known as biometrics. Some of the aspects to
stimuli to the subject in active procedures requires be considered in the design, specification, or use of
instruments such as strobe light generators, sound biomedical instruments [13-17] are:
generators, and electrical pulse generator.
Transducers: electrodes, sensors. Isolation of the subject or patient - of paramount
Signal-conditioning equipment: amplifiers, filters. importance so that the subject is not placed at the risk of
Display equipment: oscilloscopes, strip-chart or paper electrocution.
recorders, computer monitors, printers.
Volume 11 Issue 5, May 2022
www.ijsr.net
Licensed Under Creative Commons Attribution CC BY
Paper ID: SR22429215651 DOI: 10.21275/SR22429215651 362
International Journal of Science and Research (IJSR)
ISSN: 2319-7064
SJIF (2022): 7.942
Range of operation - the minimum to maximum values 4.4 Effect of the instrumentation or procedure on the
of the signal or parameter being measured. system:
Sensitivity - the smallest signal variation measurable.
This determines the resolution of the system. The placement of transducers on and connecting a system
Linearity - desired over at least a portion of the range of to instruments could affect the performance or alter the
operation. Any nonlinearity present may need to be behavior of the system, and cause spurious variations in
corrected for at later stages of signal processing. the parameters being investigated. The experimental
Hysteresis - a lag in measurement due to the direction of procedure or activity required to elicit the signal may lead
variation of the entity being measured. Hysteresis may to certain effects that could alter signal characteristics.
add a bias to the measurement, and should be corrected This aspect may not always be obvious unless careful
Frequency response - represents the variation of attention is paid. may need some rest between procedures
sensitivity with frequency. or their repetitions.
Stability - an unstable system could preclude
repeatability and consistency of measurements. 4.5 Physiological artefacts and interference:
Signal-to-noise ratio (SNR) - power-line interference,
grounding problems, thermal noise, and so on, could One of the pre-requisites for obtaining a good ECG signal
compromise the quality of the signal being acquired. A is for the subject to remain relaxed and still with no
good understanding of the signal-degrading phenomena movement. Coughing, tensing of muscles, and movement
present in the system is necessary in order to design of the limbs cause the corresponding EMG to appear as an
appropriate filtering and correction procedures. undesired artefact. In the absence of any movement by the
Accuracy - includes the effects of errors due to subject, the only muscular activity in the body would be
component tolerance, movement, or mechanical errors; that of the heart. When chest leads are used, even normal
drift due to changes in temperature, humidity, or breathing could cause the associated EMG of the chest
pressure; reading errors due to, for example, parallax; muscles to interfere with the desired ECG.
and zeroing or calibration errors.
4.6 Energy limitations:
4.Difficulties Encountered in Biomedical
Signal Acquisition and Analysis Most biomedical signals are generated at microvolt or
millivolt levels at their sources. Recording such signals
4.1 Accessibility of the variables to measurement: requires very sensitive transducers and instrumentation
with low noise levels. The connectors and cables need to
Most of the systems and organs of interest, such as the be shielded as well, in order to obviate pickup of ambient
cardiovascular system and the brain, are located well electromagnetic (EM) signals. Some applications may
within the body (for good reasons!). While the ECG may require transducers with integrated amplifiers and signal
be recorded using limb electrodes, the signal so acquired is conditioners so that the signal leaving the subject at the
but a projection of the true 3D cardiac electrical vector of transducer level is much stronger than ambient sources of
the heart onto the axis of the electrodes. Such a signal may potential interference.
be sufficient for rhythm monitoring, but could be
inadequate for more specific analysis of the cardiac 4.7 Patient safety:
system.
Protection of the subject or patient from electrical shock or
4.2 Variability of the signal source: radiation hazards is an unquestionable requirement of
paramount importance. The relative levels of any other
It is evident from the preceding sections that the various risks involved should be assessed when a choice is
systems that comprise the human body are dynamic available between various procedures, and analyzed
systems with several variables. Biomedical signals against their relative benefits. Patient safety concerns may
represent the dynamic activity of physiological systems preclude the use of a procedure that may yield better
and the states of their constituent variables. The nature of signals or results than others, or require modifications to a
the processes or the variables could be deterministic or procedure that may lead to inferior signals. Further signal-
random (stochastic); a special case is that of periodicity or processing steps would then become essential in order to
quasi-periodicity. improve signal quality or otherwise compensate for the
initial loss.
4.3 Inter-relationships and interactions among
physiological systems: References
The various systems that compose the human body are not [1] Lathi BP. Signal Processing and Linear Systems.
mutually independent; rather, they are inter-related and Berkeley-Cambridge, Carmichael, CA, 1998.
interact in various ways. Some of the interactive [2] Oppenheim AV, Willsky AS, and Nawab SH. Signals
phenomena are compensation, feedback, cause-and-effect; and Systems. Prentice- Hall, Englewood Cliffs, NJ,
collateral effects, loading, and take-over of function of a 2nd edition, 1997.
disabled system or part by another system or part. [3] Papoulis A. Signal Analysis. McGraw-Hill, New