Professional Documents
Culture Documents
NAME OF WORK:- PROVIDING IRRIGATION FACILITY UNDER HP SHIVA PROJECT FOR CHAUNTRA,GOPALPUR AND DHARAMPUR BLOCKS, DISTRICT MANDI(HIMACHAL PRADESH)- PACKAGE-07
Name of Scheme:- LIS Son Khad for Rasher, Block Gopalpur
Rising Main:- Proposed Collection Tank to MT Rasher
Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Dec.
DATA: LIS Son Khad for Rasher, Block Gopalpur ------Proposed Collection Tank to MT Rasher
Max.(design) discharge = 345.60 Kld GMS tube as per IS:1239 - 2004 (Part-I): MSERW Pipe IS/ISO:3183-2007 :
Dia of Pipe line (internal) = 80.00 mm Outer Dia of pipeline = 89.90 mm Outer dia of Pipe = 0.00 mm
RD of End (delivery)Pt. = 378.00 m Wall thk: (H) = GI (H) GI (M) Grade of pipe = L210 or A Yld. Stress = 210.00 Mpa
RL of End (delivery Pt.) = 1097.97 m 4.80 mm 4.00 mm Stress = Yld. Str. = 60.00 % = 126.00 Mpa
Co-eff.of pipe friction ,'C' = 100.00 Mill Tolerance = 12.50 % Joint Efficiency, JE = 0.85 Mill Tolerance = 12.50 %
Corrosion allowance (thk) = as given below Joint Efficiency, JE = 0.85 MSERW Pipe IS/ISO:3183-2007 : Yield Stress = 85.00
Avr.Pipe thk.(Assumed) = 4.80 mm (for water Hammer effect) Outer Dia of pipeline = 0.00 mm % = 246.50 Mpa
Mod.of elasticity of pipe = 2.10E+10 Kg/m 2 Fibre Stress , S = 1/3 x 320 = 106.67 Mpa Grade of pipe = L290 or X 42 Yld. Stress = 290.00 Mpa
Wave velocity, C= 1320.64192 m/ sec. Joint Efficiency, JE = 0.85 Mill tolerance = 12.50 %
Corrosion allowance (thk) = 1.65 mm for GMS tube or MSERW Pipe (IS/ISO:3183-2007)= 1.65 mm % MSERW Pipe (IS/ISO: 3183-2007) = 1.65 mm
< -------------- DATA ------------------ >
Wall thk.(Barlow equ) t =P.D Wall Thickness i/c
Nominal Working
m Residual head)
(i/c
Pressure for
R.L. of Lower Point
Water Hammer
IS/ISO:318
IS/ISO:318
IS/ISO:318
IS/ISO:318
Pipe to be
(for losses)
MSERW
MSERW
MSERW
provided as per
IS:1239 - 1990
IS:1239 - 2004
3-2007
Wall Thickness
(1st Pt)
To (2nd Pt)
provided
1.5 x (6 +8)
(6 + 7 + 8)
Pipe
Pipe
Pipe
Pipe
1.5 x (8)
From (1st)
(Part-I)
code
(11,12,13)
Type and Class of Pipe Line
P = Max.
Col. L210 or L290 or L210 or L290 or
3.0
(6+8) A X 42 A X 42 From RD To RD
(m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Reqd. Use
1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1 0 200 996.59 378.00 6.36 107.13 104.38 166.12 156.57 217.87 217.87 110.74 1.08 -- -- 2.87 -- -- 2.87 4.00 GMS tube as per IS:1239 - 2004 (Medium) 17 17 0 to 200
2 200 378 1046.90 178.00 3.00 107.13 54.07 85.60 81.10 164.19 164.19 57.07 0.81 -- -- 2.56 -- -- 2.56 4.00 GMS tube as per IS:1239 - 2004 (Medium) 5 5 200 to 378