WATER CORPORATION
DONGARA WRRF
SPECIFICATION
FOR THE SUPPLY AND INSTALLATION OF
HIGH SPEED FLOATING AERATORS
Revision D
Oct 2023
Document History & Status
Page i
SPECIFICATION – FLOATING AERATORS – HIGH SPEED
CONTENTS
1 GENERAL ............................................................................................... 3
1.1 Scope of Work ...........................................................................................................3
1.2 Process Description .................................................................................................3
1.3 Codes and Standards ...............................................................................................4
1.4 Reference Documents ..............................................................................................4
1.5 Equipment List ..........................................................................................................4
1.6 Submittals for Review (After Award of Contract) ..................................................5
1.7 Submittals Prior to Equipment Delivery .................................................................5
1.8 Site Environmental Conditions ................................................................................5
1.9 Service Conditions ....................................................................................................5
1.10 Site Utilities ................................................................................................................5
1.11 Labelling .....................................................................................................................6
1.12 Shipment, Protection and Storage ..........................................................................6
1.13 Special Considerations ............................................................................................6
2 PRODUCTS ............................................................................................. 7
2.1 General .......................................................................................................................7
2.2 Design Criteria ...........................................................................................................7
2.3 Materials .....................................................................................................................8
2.4 Equipment Design and Construction ......................................................................8
2.5 Electrical and Controls .......................................................................................... 10
2.6 Protective Coatings ............................................................................................... 10
2.7 Spare Parts ............................................................................................................. 10
Page ii
1 General
1.1.1 Supply equipment in accordance with the requirements of the General Conditions
of Contract, Special Conditions of Contract, Technical Specifications, Technical
Data Sheets, Drawings, and the Standard Specifications.
1.1.2 Supply, deliver, install, test, and commissioning of high-speed floating aerators in
the aerated and the three sedimentation lagoons.
1.1.3 Supply each aerator complete with motor, electrical power supply cables, cable
floats, drive shaft, impeller, volute, flotation assembly, suction cone, anti-vortex
baffles, anti-erosion plates, replaceable mooring eyes, power supply cables,
tethering cables, and all specified appurtenances.
1.1.4 Provide instructions and procedures for installation, start-up, testing and
commissioning.
1.1.6 Supply spare parts, lubricants, and special tools, including any special lifting
devices or beams necessary for installation, removal of individual components for
maintenance or overhaul.
1.1.7 Provide all Quality Assurance services associated with the equipment supply
including the Manufacturer’s Data Record.
The scope of works includes replacement of all the aerators in the aerated lagoon and
the sedimentation lagoons. The aerated lagoon is equipped with four aerators
(3duty/1standby) and each sedimentation lagoon with a single duty aerator.
The aerated lagoon is aerated to allow for the biodegradation of the BOD in the influent
flows.
The sedimentation lagoons are aerated to maintain an aerobic layer on the surface of the
lagoon and to exhaust carbon dioxide to limit algae growth. In addition, the sedimentation
lagoons are aerated for stabilising biosolids settled out in the lagoons.
Replacement of the existing aerators of the aerated and the sedimentation lagoons are
required since the existing units are structurally unsafe, worn out, and have reached the
end of their operating life.
1.3 Codes and Standards
All equipment and procedures to comply with the relevant International and Australian
Standards and the requirements of the relevant Australian Statutory Authorities.
1.4.1 DS95 – Standard for the selection, preparation, application, inspection and testing
of protective coating on Water Corporation assets - Sections A1, D1 and H2.
1.4.3 Water Corporation Electrical Design Standard DS26-06 Type Specification for
Standard Cage Induction Motors
1.4.7 Water Corporation Mechanical Design Standard DS35 Auxiliary Plant – Mechanical
The equipment supplier shall supply equipment labelled as per the below equipment list.
1.8.1 The listed equipment will be installed in the aerated and sedimentation lagoons of
the Dongara WRRF.
1.8.3 The equipment supplier shall design equipment to operate satisfactorily under the
following site environmental conditions:
a) Temperature: 0°C to 50 °C
b) Humidity: 10% - 100% relative humidity
1.8.4 The equipment supplier shall design equipment suitable for installation in the
above conditions and be resistant to attack from any extraneous gases such as
hydrogen sulphide that could be present at a sewage treatment plant.
1.9.1 Select and design aerators specifically for continuous or intermittent operation
without fouling caused by debris, screenings, and material in the influent flow.
1.9.2 Fluid in the plant lagoons is expected to contain a combination of fibrous and plastic
materials, grit and organic debris from road litter.
1.11 Labelling
1.11.1 Clearly label each equipment item with its equipment number in a readily
discernible position. Provide engraved stainless-steel labels with capital block
lettering not less than 6mm high.
1.11.2 Attach a technical data label to each item of equipment showing the name of the
item, name of manufacturer, model and serial numbers, rated speed and capacity
as appropriate. Such information depends on the equipment item, e.g. for a
gearbox show the reduction ratio, for a motor show the rated voltage, full load
current, etc.
1.11.3 Provide all necessary warning or hazard labels at visible locations complying fully
with statutory requirements to ensure the safety of operating and maintenance staff.
1.11.4 Use a minimum of two 316 stainless steel rivets or screws for fixing labels.
1.11.5 Prepare a schedule of all equipment labels and submit to the Purchaser for
approval prior to manufacture.
1.12.1 Prior to shipment, protect equipment adequately against corrosion and accidental
damage by proper packing and/or by other approved means for the whole period of
transit, storage, and installation.
1.12.2 Deliver and offload equipment at the Site intact and undamaged. Pack equipment
to withstand any rough handling that might occur throughout shipping, transit, and
associated loading and offloading.
1.12.3 Pack and protect equipment for outside storage at the Dongara WRRF or other
nominated storage areas until required for installation.
1.12.4 Repair at the Supplier’s expense any damage to paintwork, fittings, sheet metal
work, electrical components or instruments sustained during transportation and
handling.
1.13.2 Prior to any fabrication, verify all design dimensions, requirements, and parameters
included in this specification.
1.13.3 Prior to any fabrication, ensure compliance with the Water Corporation Welding
Specification WS-1.
1.13.4 Prior to any fabrication, obtain approval on QA System, Inspection Test Plan
Welding Procedures, and Welder Qualifications.
2 Products
2.1 General
2.1.3 By agitating the wastewater vigorously, air is entrained in the wastewater causing
rapid change in the air-water interface to facilitate dissolution of air.
2.1.4 Supply equipment of proven design for effective aeration and mixing of the lagoon
contents.
2.1.6 Design, size, and select all aerator components to meet the torque requirements
under full load start-up and operating conditions.
The equipment supplier shall design equipment in accordance with the following design
criteria:
2.2.1 Provide products, modified as necessary by the manufacturer, to meet the following
operating conditions:
2.2.2 Ensure that maximum power absorbed by aerator not to exceed 90% of installed
power.
2.2.3 Size the aerated lagoon aerators not to damage the aerated lagoon clay liner.
2.2.4 Size sedimentation lagoon aerators not to disturb the sludge layer in the
sedimentation tanks designed to build-up to a depth of 1.4m below the TWL. The
average depth of the three sedimentation lagoons is about 2.8m.
2.2.5 Provide all equipment with a minimum design life of 25 years based on continuous
operation at the specified design loadings.
2.3 Materials
Component Material
Aerator impeller Stainless steel 316L
Aerator volute with gussets Stainless steel 316L
Suction cone, anti-vortex baffles, and anti-
Stainless steel 316L
erosion plates
Aerator motor frame, lifting saddle, and spray Stainless steel 316L
deflector
Aerator float and mooring eyes Stainless steel 316L
Aerator tethering cables Stainless steel 316L
Aerator guideposts (existing) Stainless steel 316L
Bolts, fasteners, and miscellaneous hardware Stainless steel 316L
2.4.1 General
a) Design all aerator components to passively resist corrosion from free and
combined chlorine residuals, chlorides, hydrogen sulphide fumes,
condensation containing sulphuric acid residual, sulphates and any other
constituents normally found at facilities treating municipal sewage.
b) Isolate or carefully select dissimilar metals to prevent galvanic corrosion.
c) Use the same size aerator frame and floats for all the aerators included in
this specification.
2.4.3 Volute
a) Design aerator motor frame with a mounting flange to support the aerator
motor.
b) Design aerator motor frame with a lifting saddle.
c) Bolt motor frame down to the aerator float.
d) Design motor frame suitable for the design loads imposed by the impeller.
e) Equip aerator with an anti-splash shroud / spray deflector to protect the
motor.
2.4.6 Motor
2.5.1 Provide aerators with suitably sized electrical supply cables complete with cable
floats. Allow for 30m minimum cable length for the individual aeration lagoon
aerators and 20m minimum for the individual sedimentation lagoon aerators.
2.5.2 Equip aerator power supply cables with decontactor plugs compatible with the
existing plant decontactor socket outlets.
a) The supplier shall ensure that the supplied equipment is compatible with the
existing plant control system.
b) The supplier shall provide a functional control description for the aerators,
which, as a minimum, includes the following:
• Any safety interlocks required for personnel or equipment protection.
• Required equipment fail-safe state in the event of power failure.
• Crash stop requirements.
• Alarm requirements.
• Any trending requirements and data to be recoded (specify the data
items) that would enable improved performance or enhance
maintenance and reliability of the equipment or system.
• Control sequences including normal and abnormal operation.
2.6 Protective Coatings
2.6.1 Apply coating systems in accordance with Water Corporation’s DS95 – Standard
for the selection, preparation, application, inspection and testing of protective
coating on Water Corporation assets – Sections A1, D1 and H2.
2.7.1 Nominate a recommended list of spare parts and stock levels to be held both at the
plant and at the store of the Supplier’s local representative (in Perth). This list to
include the following:
a) Description.
b) Part Number, make and model.
c) Manufacturer, Supplier and Local Agent Details.
d) Origin of spare part and delivery lead time
2.7.2 Provide any special tools required for the normal operation and maintenance of the
equipment.
3.1.1 Conduct certified performance test for compliance with the specified performance
requirements.
3.1.2 Shop assemble and test equipment to ensure proper assembly, alignment and
adequacy of all functional parts and drives.
3.1.3 Provide 4 weeks’ notice in advance for certified performance testing, inspection of
materials, components, assemblies, and fabrications used in the Works.
3.1.5 Provide a program of all tests and notice of at least four weeks prior to commencing
any test. The Factory tests may be viewed and verified by an independent
Inspector.
3.1.6 Conduct Factory Acceptance Tests on all equipment to verify the specified design
and performance requirements prior to dispatch.
3.2.1 Provide 4 weeks’ notice in advance for equipment installation and commissioning.
3.2.2 Lift out and remove existing slow speed aerators to a location on site identified by
the Water Corporation representative.
3.2.3 Replace the four aerated lagoon aerators one at a time to ensure at least three
functional aerated lagoon aerators at any given time.
3.2.4 Replace the three sedimentation lagoon aerators one at a time to ensure at least
two functional sedimentation lagoon aerators at any given time.
3.2.5 Install new aerators complete with new tethering cables and power supply cables.
3.2.6 Provide 4 weeks’ notice to Water Corporation representative to witness any testing,
as per the agreed ITP.
3.2.9 Provide a written report at the completion of the pre-commissioning certifying that
the equipment has been correctly installed and aligned, is free from any undue
stress imposed by connecting piping, chutes, conveyors or other adjoining
equipment, support structures, fixings or anchor bolts and that the entire system is
fully lubricated, connected and operates satisfactorily.
3.3 Commissioning
a) The installation and any other related systems are clear of all debris and
matter that could cause damage to the equipment.
b) No-load operation to demonstrate that all equipment functions successfully,
both separately and as components of integrated systems.
c) Check normal start up and shut down.
d) Check emergency shutdown.
e) Check for smooth running of all equipment under field control.
f) Check all sequences under manual control.
g) Check all sequences under SCADA control.
h) Any other manufacturer’s recommended checks.
i) Equipment performance at the specified duties and operating conditions.
Project:
AER201, AER202, AER203, and AER204 1 of 7
Data Sheet No: Seq No
Dongara WRRF
1 B
REASON FOR ISSUE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Page 1 of 7
DATA / REQUISITION SHEET FOR:
SITE CONDITIONS
TEMPERATURE RANGE 0 - 50°C
INSTALLATION LOCATION Dongara WRRF site
ENVIRONMENT Aerators to be installed within Aerated Lagoon, Atmospheric salt - Coastal breezes, sand.
OPERATIONAL DATA
All items of equipment shall comply with the latest edition of the Australian Standards
All items of equipment shall comply with the Water Corporation documents (listed)
REFERENCE DOCUMENTS
DS26-01 Type Specification - Electrical Introduction
DS-95 Protective Coatings - A1, D1, H2.
DS30-01 Glossary - Mechanical
DS30-02 General Design Criteria - Mechanical
DS34 - Wastewater Treatment Plants - Mechanical
DS35 Auxiliary Plant - Mechanical
DS38-01 - Installation Mechanical
DS38-02 - Flanged Connectins
TECHNICAL DATA
DETAILS OF AERATED LAGOON
VOLUME 1957 m3
LENGTH (FLOOR) 14.5 m
WIDTH (FLOOR) 14.5 m
LENGTH (TWL) 33.7m
WIDTH (TWL) 33.7m
DEPTH 3.2
TWL IN AERATED LAGOON RL15.25
FL IN AERATED LAGOON RL12.05
FLUID DATA
FLUID TYPE Screened Raw Sewage / Mixed Liquor Suspended
PERFORMANCE 4 off 7.5kW aerators with minimum rating of 1.5kgO2/kWh
FLUID SOLIDS CONTENT 0.1 - 0.5 % w/v
MAX PARTICLE SIZE Rags and debris
CONTAMINANTS Suspended biological organics
CORROSION / EROSION Dongara is a coastal plant. All aerator components to passively resist corrosion from free and combined chlorine residuals, chlorides,
hydrogen sulphide fumes, condensation containing sulphuric acid residual, sulphates and any other constituents normally found at
facilities treating municipal sewage
RANGE MAX MIN Notes
- Temperature 27 °C 17 °C
- pH 8.1 6.4
GENERAL DETAILS
AERATOR SPEED *
DRIVER SPEED *
IMPELLER TYPE Propeller/Turbine/Paddle/Open/Shrouded/Axial/Circular/Radial/Vortex
Page 2
DRAFT TUBE Yes / No
ANTI-VORTEX BAFFLES Yes / No
ANTI-EROSION PLATE Yes / No
DIRECTION OF ROTATION Clockwise/Anti-clockwise (from Non-Drive End)
NUMBER OF BLADES *
IMPELLER LOCATION Overhung/Between Bearing
ATTACHMENT METHOD Taper & Key/Key/Pin/Expanded/Pressed/Welded/Key/Interference Fit
% RESERVE BUOYANCY FOR STABILITY %
VIBRATION PROTECTION Yes / No
MIN. ALLOWABLE AERATOR DEPTH *
IDEAL AERATOR DEPTH *
EXPECTED TIME IN SERVICE BEFORE
MAINTENANCE
CURVE NUMBERS
- SINGLE OPERATION N/A
- PARALLEL OPERATION N/A
IMPELLER / BLADE TYPE *
IMPELLER / BLADE DIAMETER *
MAX. SOUND POWER LEVEL < 80 dB @ 1 m
Page 3
ACCESSORIES (Supplier to complete)
GUIDE RAILS NO
GUIDE RAIL BASE SUPPORT BOLTS N/A
CONTROL PANEL N/A
SUPPORTING FRAME N/A
TEMPERATURE SWITCH *
MATERIALS OF CONSTRUCTION
The supplier shall outline their materials with specifications to ensure resistance against pitting and corrosion for wetted parts for a 25 year design life handling sludge.
PART MATERIAL Standard Grade
IMPELLER/BLADES SS316L * *
SHAFT SS 316L * *
VOLUTE (DRAFT TUBE) WITH GUSSETS SS 316L * *
SUCTION CONE, ANTI-VORTEX BAFFLES, AND SS 316L * *
ANTI-EROSION PLATES
AERATOR MOTOR FRAME, LIFTING SADDLE, SS 316L * *
AND SPRAY DEFLECTOR
AERATOR FLOAT AND MOORING EYES SS316L * *
AERATOR TETHERING CABLES SS316L * *
BOLTS, FASTENERS, AND MISCELLANEOUS SS316 * *
HARDWARE
THETHERING CABLES SS316L
OTHER
PAINTING
MOTOR
PAINT MANUFACTURER *
PAINT TYPE *
COLOUR *
Page 4
NOISE YES YES FACTORY
VIBRATION YES YES FACTORY
SHIPPING DETAILS
METHOD OF SUPPLY (PLEASE DESCRIBE IF *
AERATORS TO BE DELIVERED IN COMPONENTS -
NOT FULLY ASSEMBLED)
MASS OF AERATOR ASSEMBLY *
MASS OF ACCESSORIES *
TOTAL WEIGHT OF SHIPPING *
DIMENSIONS * L (mm) * W (mm) * H (mm)
NOTES
1 ITEMS MARKED WITH * TO BE COMPLETED BY SUPPLIER.
2
Page 5
DATA / REQUISITION SHEET FOR
1) ALL REFERENCES TO "ANNEXURE" IN THE SPECIFICATION SHALL REFER TO THIS DATA SHEET.
2) SUPPLIER IS TO COMPLETE THE "SUPPLIER MOTOR DATA" SECTION OF THIS DATA SHEET, IN LIEU OF THE "TENDER TECHNICAL RESPONSE SECTION" IN THE SPECIFICATION.
3) MOTORS SHALL HAVE S1 POWER RATINGS OF AT LEAST 110% OF THE MAXIMUM LOAD (ABSORBED POWER) OF THE DRIVEN EQUIPMENT.
4) MOTOR ANTI-CONDENSATION HEATERS SHALL BE PROVIDED AS INDICATED ON THIS DATA SHEET.
- ANTI-CONDENSATION HEATERS SHALL BE SIZED TO RAISE THE TEMPERATURE INSIDE THE MOTOR SEVERAL DEGREES ABOVE THE DEW POINT TEMPERATURE
- ANTI-CONDENSATION HEATERS SHALL BE LOCATED SUCH THAT HEAT DISSIPATION DOES NOT DAMAGE OR EMBRITTLE THE MOTOR PAINT FINISH, MOTOR WINDING INSULATION,
OR SUPPLY CABLES.
5) CABLE LENGTH TO BE MINIMUM 25m
COMMENTS
NOTES
1 ITEMS MARKED WITH * TO BE COMPLETED BY SUPPLIER.
Data Sheet
Client: Description:
Project:
AER301, AER302, and AER303 1 of 7
Data Sheet No: Seq No
Dongara WRRF
2 B
REASON FOR ISSUE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Page 1 of 7
DATA / REQUISITION SHEET FOR:
SITE CONDITIONS
TEMPERATURE RANGE 0 - 50°C
INSTALLATION LOCATION Dongara WRRF site
ENVIRONMENT Aerators to be installed within Sedimentation Lagoons, Atmospheric salt - Coastal breezes, sand.
OPERATIONAL DATA
All items of equipment shall comply with the latest edition of the Australian Standards
All items of equipment shall comply with the Water Corporation documents (listed)
REFERENCE DOCUMENTS
DS26-01 Type Specification - Electrical Introduction
DS-95 Protective Coatings - A1, D1, H2.
DS30-01 Glossary - Mechanical
DS30-02 General Design Criteria - Mechanical
DS34 - Wastewater Treatment Plants - Mechanical
DS35 Auxiliary Plant - Mechanical
DS38-01 - Installation Mechanical
DS38-02 - Flanged Connectins
TECHNICAL DATA
DETAILS OF SEDIMENTATION LAGOONS No.1 No.2 No.3
VOLUME 1809 m3 1733 m3 1648 m3
LENGTH (FLOOR) 16.0 m 16.0m 16.0m
WIDTH (FLOOR) 16.0 m 16.0m 16.0m
LENGTH (TWL) 33.2m 32.8m 32.3m
WIDTH (TWL) 33.2m 32.8m 32.3m
DEPTH 2.87 2.8 2.72
TWL IN SEDIMENTATION LAGOONS RL15.17 RL15.10 RL15.02
FL IN SEDIMENTATION LAGOONS RL12.30 RL12.30 RL12.30
FLUID DATA
FLUID TYPE Screened Raw Sewage / Mixed Liquor Suspended
PERFORMANCE 3 off 2.2kW aerators with minimum rating of 1.5kgO2/kWh
FLUID SOLIDS CONTENT 0.1 - 0.5 % w/v
MAX PARTICLE SIZE Rags and debris
CONTAMINANTS Suspended biological organics
CORROSION / EROSION Dongara is a coastal plant. All aerator components to passively resist corrosion from free and combined chlorine residuals, chlorides,
hydrogen sulphide fumes, condensation containing sulphuric acid residual, sulphates and any other constituents normally found at
facilities treating municipal sewage
RANGE MAX MIN Notes
- Temperature 27 °C 17 °C
- pH 8.1 6.4
Page 2
GENERAL DETAILS
AERATOR SPEED *
DRIVER SPEED *
IMPELLER TYPE Propeller/Turbine/Paddle/Open/Shrouded/Axial/Circular/Radial/Vortex
DRAFT TUBE Yes / No
ANTI-VORTEX BAFFLES Yes / No
ANTI-EROSION PLATE Yes / No
DIRECTION OF ROTATION Clockwise/Anti-clockwise (from Non-Drive End)
NUMBER OF BLADES *
IMPELLER LOCATION Overhung/Between Bearing
ATTACHMENT METHOD Taper & Key/Key/Pin/Expanded/Pressed/Welded/Key/Interference Fit
% RESERVE BUOYANCY FOR STABILITY %
VIBRATION PROTECTION Yes / No
MIN. ALLOWABLE AERATOR DEPTH *
IDEAL AERATOR DEPTH *
EXPECTED TIME IN SERVICE BEFORE
MAINTENANCE
CURVE NUMBERS
- SINGLE OPERATION N/A
- PARALLEL OPERATION N/A
IMPELLER / BLADE TYPE *
IMPELLER / BLADE DIAMETER *
MAX. SOUND POWER LEVEL < 80 dB @ 1 m
Page 3
NON DRIVEN END BEARING DETAILS (Supplier to complete)
BEARING MANUFACTURER *
BEARING TYPE *
MODEL NUMBER *
LUBRICATION REQUIRED *
LUBRICATION FREQUENCY *
LUBRICATION QUANTITY *
L10 LIFE 100,000 hours
MATERIALS OF CONSTRUCTION
The supplier shall outline their materials with specifications to ensure resistance against pitting and corrosion for wetted parts for a 25 year design life handling sludge.
PART MATERIAL Standard Grade
IMPELLER/BLADES SS316L * *
SHAFT SS 316L * *
VOLUTE (DRAFT TUBE) WITH GUSSETS SS 316L * *
SUCTION CONE, ANTI-VORTEX BAFFLES, AND SS 316L * *
ANTI-EROSION PLATES
AERATOR MOTOR FRAME, LIFTING SADDLE, SS 316L * *
AND SPRAY DEFLECTOR
AERATOR FLOAT AND MOORING EYES SS316L * *
AERATOR TETHERING CABLES SS316L * *
BOLTS, FASTENERS, AND MISCELLANEOUS SS316 * *
HARDWARE
THETHERING CABLES SS316L
OTHER
PAINTING
MOTOR
PAINT MANUFACTURER *
PAINT TYPE *
COLOUR *
Page 4
WEIGHTS & DIMENSIONS
MASS OF IMPELLER (SHAFT & BLADES) * DIAMETER OF SUCTION CONE AT *
ENTRY
MASS OF VOLUTE WITH GUSSETS * DIAMETER OF SUCTION CONE AT EXIT *
SHIPPING DETAILS
METHOD OF SUPPLY (PLEASE DESCRIBE IF *
AERATORS TO BE DELIVERED IN COMPONENTS -
NOT FULLY ASSEMBLED)
MASS OF AERATOR ASSEMBLY *
MASS OF ACCESSORIES *
TOTAL WEIGHT OF SHIPPING *
DIMENSIONS * L (mm) * W (mm) * H (mm)
NOTES
1 ITEMS MARKED WITH * TO BE COMPLETED BY SUPPLIER.
2
Page 5
DATA / REQUISITION SHEET FOR
1) ALL REFERENCES TO "ANNEXURE" IN THE SPECIFICATION SHALL REFER TO THIS DATA SHEET.
2) SUPPLIER IS TO COMPLETE THE "SUPPLIER MOTOR DATA" SECTION OF THIS DATA SHEET, IN LIEU OF THE "TENDER TECHNICAL RESPONSE SECTION" IN THE SPECIFICATION.
3) MOTORS SHALL HAVE S1 POWER RATINGS OF AT LEAST 110% OF THE MAXIMUM LOAD (ABSORBED POWER) OF THE DRIVEN EQUIPMENT.
4) MOTOR ANTI-CONDENSATION HEATERS SHALL BE PROVIDED AS INDICATED ON THIS DATA SHEET.
- ANTI-CONDENSATION HEATERS SHALL BE SIZED TO RAISE THE TEMPERATURE INSIDE THE MOTOR SEVERAL DEGREES ABOVE THE DEW POINT TEMPERATURE
- ANTI-CONDENSATION HEATERS SHALL BE LOCATED SUCH THAT HEAT DISSIPATION DOES NOT DAMAGE OR EMBRITTLE THE MOTOR PAINT FINISH, MOTOR WINDING INSULATION,
OR SUPPLY CABLES.
5) CABLE LENGTH TO BE MINIMUM 25m
COMMENTS
NOTES
1 ITEMS MARKED WITH * TO BE COMPLETED BY SUPPLIER.