MULTI V 5 Catalogue - Small
DUAL
SENSING
CONTROL
TEMPERATURE HUMIDITY
SENSOR SENSOR
ABOUT LG BENEFITS OF LG MULTI V
Ever since manufacturing of Korea’s first home grown air conditioner began in 1968, LG has remained at the forefront of air
BENEFITS FOR BUILDING OWNER
conditioning innovation. LG has not only been the leading manufacturer of top notch energy efficient solution provider, but also has
been amongst the top selling air conditioning brands globally.
With more and more focus on providing superior quality products, our team of experts work tirelessly to create solutions based on Efficient Management & Cost Reduction
latest technologies to provide faster and smarter solutions.
LG India through its world-class manufacturing facilities in Greater Noida & Pune, has been reaching out to its customers with its
comprehensive product portfolio that includes chillers, VRF systems, ducted splits, rooftop units, cassette units, floor standing units Reliability Guaranteed in Every Aspect
and building management systems (BMS).
The company also produces outstanding air conditioning professionals at its esteemed academies located in Delhi & Pune, India. It
Customised Comfort and Solution
has nearly 80 academies worldwide. These centres of excellence, provide workshops and training programs that offer invaluable
hands-on experience. LG also provides useful tools for HVAC system engineers and installers, including its time saving LG Air
Conditioner Technical Solutions (LATS) software.
Green Solutions
INDIA
Smart Building Solutions
Versatile Solutions
Gr. Noida Factory Pune Factory Noida Innovation Gallery Pune Academy Bengaluru Academy
HP Convenient Functions 16 18 20 22
Combination Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
Model Name
Independent Unit JRUV160LTE5 JRUV180LTE5
* Dual Sensing Smart JRUV200LTE5 JRUV220LTE5
Load Control based, below 50% humidity, model ARUN260LTE5
● ● ● ●
■ ■ ■ ■
● ● ●
Compact ○ ○ ○
• Saves floor space
• Flexible design applications
- Slim, light and wide line up
MULTI V S (4 ~ 14HP) ● ● ●
- Combination of indoor unit
(Up to 23 Units)
• For small / medium building
□ □ ■
● ● ● ●
● ● ● ● ● ●
MULTI V
WATER IV ■ ■ ■
Cooling only
4 5
INDOOR UNITS LINE-UP INDOOR UNITS FEATURE OVERVIEW
4th
generation
Standard ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ▲*
Wall
Mounted Unit
Round Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ●
(570 x 570)
4th
generation 4 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
Ceiling (840 x 840)
Mounted Unit
2 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
1 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
High Static ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th
generation
Ceiling
Concealed
Duct Low Static ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Fresh Air Intake Units
4th generation
Floor Standing ● ●
Floor Standing
Low Temperature ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
Hydro Kit
High Temperature ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
Energy Recovery ● ● ● ● ● ● ●
without Humidifier ● ● ●
Ventilator with
DX Coil
6 7
MULTI V 5 SPECIFICATIONS
JRUN160LTE5 / JRUN180LTE5
JRUN200LTE5 / JRUN220LTE5
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local
and national codes. And “Electric characteristics” chapter should
be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Therefore, these values can be increased owing to ambient conditions during operation. 4. Performances are based on the following conditions :
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor
Ambient Temp. 35°CDB / 24°CWB
• Interconnected Pipe Length is 7.5m and difference of
Elevation (Outdoor ~ Indoor Unit) is 0m.
5. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2,087.5)
8 9
Motor Output x Number W x No. 1,500 x 1 1,500 x 1 1,500 x 1 1,500 x 1
Fan Air Flow Rate (High) m3/min x No. 270 x 1 270 x 1 270 x 1 270 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Pipe Connections
Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127)
Dimensions (W x H x D) mm x No. (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1
Net Weight kg x No. 200 x 1 247 x 1 257 x1 257 x1
Weight
Shipping Weight kg x No. 208 x 1 255 x 1 265 x 1 265 x 1
HIGH EFFICIENCY COOLING ONLY Sound Pressure Level Cooling dB(A) 62.0 62.0 62.0 62.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
JRUV080LTE5 / JRUV100LTE5 Refrigerant Name R410A R410A R410A R410A
Refrigerant
JRUV120LTE5 / JRUV140LTE5 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of maximum connectable indoor units 26 (40) 29 (45) 32 (50) 35 (44)
HP 8 10 12 14 Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200%
Combination Unit JRUV080LTE5 JRUV100LTE5 JRUV120LTE5 JRUV140LTE5
Model Name
Independent Unit JRUV080LTE5 JRUV100LTE5 JRUV120LTE5 JRUV140LTE5
kW 22.4 28.0 33.6 39.2
Cooling kcal/h 19,300 24,100 28,900 33,700
Btu/h 76,400 95,500 114,600 133,800
Capacity (Rated)
kW - - - - HIGH EFFICIENCY COOLING ONLY
Heating kcal/h - - - -
Btu/h - - - -
Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray ARUV240LTE5 / ARUV260LTE5
Heat Exchanger Black Fin Black Fin Black Fin Black Fin
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll
Compressor Starting Method DC Inverter Starting DC Inverter Starting DC Inverter Starting DC Inverter Starting
Number of Compressor 1 1 1 1
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Axial Flow Fan HP 24 26
Motor Output x Number W x No. 900 x 1 900 x 1 900 x 1 900 x 1 Combination Unit ARUV240LTE5 ARUV260LTE5
Model Name
Fan Air Flow Rate (High) m3/min x No. 210 x 1 210 x 1 210 x 1 210 x 1 Independent Unit ARUV240LTE5 ARUV260LTE5
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
kW 67.2 72.8
Discharge Side / Top TOP TOP TOP TOP
Cooling kcal/h 57,800 62,600
Liquid Pipe mm (inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2)
Pipe Connections Btu/h 229,300 248,400
Gas Pipe mm (inch) 19.05 (3/4) 22.2 (7/8) 28.58 (1-1/8) 28.58 (1-1/8) Capacity (Rated)
kW - -
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127)
Heating kcal/h - -
Dimensions (W x H x D) mm x No. (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1
Btu/h - -
Net Weight kg x No. 177 x 1 177 x 1 177 x 1 186 x 1
Weight Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Shipping Weight kg x No. 184 x 1 184 x 1 184 x 1 193 x 1
Heat Exchanger Black Fin Black Fin
Sound Pressure Level Cooling dB(A) 58.5 58.5 59.0 60.0
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll
mm x No.
2
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Compressor Starting Method DC Inverter Starting DC Inverter Starting
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Number of Compressor 2 2
Refrigerant Type Axial Flow Fan Axial Flow Fan
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Motor Output x Number W x No. 900 x 2 900 x 2
Number of maximum connectable indoor units 13 (20) 16 (25) 20 (30) 23 (35) Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1
Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200% Drive DC INVERTER DC INVERTER Note : 1. Due to our policy of innovation some specifications
Discharge Side / Top TOP TOP may be changed without notification.
Liquid Pipe mm (inch) 15.88 (5/8) 19.05 (3/4) 2. Wiring cable size must comply with the applicable local and
Pipe Connections national codes. And “Electric characteristics” chapter should
Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
be considered for electrical work and design.
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) Especially the power cable and circuit breaker should be
HIGH EFFICIENCY COOLING ONLY Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 selected in accordance with that
3. Sound pressure level is measured on the rated condition in
Net Weight kg x No. 276 x 1 276 x 1
Weight the anechoic rooms by ISO 3745 standard.
Shipping Weight kg x No. 290 x 1 290 x 1
JRUV160LTE5 / JRUV180LTE5 Sound Pressure Level Cooling dB(A) 67.0 67.0
Therefore, these values can be increased owing to ambient
conditions during operation.
JRUV200LTE5 / JRUV220LTE5 mm2 x No. 4. Performances are based on the following conditions :
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) • Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB,
Refrigerant Name R410A R410A Outdoor Ambient Temp. 35°CDB / 24°CWB
Refrigerant • Interconnected Pipe Length is 7.5m and difference of
Control Electronic Expansion Valve Electronic Expansion Valve
Elevation (Outdoor ~ Indoor Unit) is 0m.
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50
HP 16 18 20 22 5. This product contains Fluorinated greenhouse gases.
Number of maximum connectable indoor units 39 (61) 42 (64) (R410A, GWP(Global warming potential) = 2,087.5)
Combination Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
Model Name Maximum Indoor Unit Combination Ratio* 200% 200% * The recommended ratio is 130%.
Independent Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
kW 44.8 50.4 56.0 61.6
Cooling kcal/h
Btu/h
38,500
152,900
43,300
172,000
48,200
191,100
53,000
210,200
KEY FEATURES
Capacity (Rated)
kW - - - -
Heating kcal/h - - - -
Btu/h - - - - ENERGY SAVING AND OPTIMISED HEAT EXCHANGER WITH BLACK FIN
Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray COOLING THROUGH DUAL SENSING FOR CORROSION RESISTANCE
Heat Exchanger Black Fin Black Fin Black Fin Black Fin (TEMPERATURE AND HUMIDITY SENSOR)
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll
Compressor Starting Method DC Inverter Starting DC Inverter Starting DC Inverter Starting DC Inverter Starting
Number of Compressor 1 2 2 2 LARGE CAPACITY OUTDOOR UNITS INCREASED AIR FLOW RATE
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Axial Flow Fan (SINGLE OUTDOOR UP TO 26 HP) WITH BIOMIMETICS FAN
Motor Output x Number W x No. 1,500 x 1 1,500 x 1 1,500 x 1 1,500 x 1
Fan Air Flow Rate (High) m3/min x No. 270 x 1 270 x 1 270 x 1 270 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
HIGH COMPRESSOR RELIABILITY
Discharge Side / Top TOP TOP TOP TOP AUTO DUST REMOVAL
Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) WITH OIL LEVEL SENSOR
Pipe Connections
Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
10 Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) 11
Dimensions (W x H x D) mm x No. (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1
Net Weight kg x No. 200 x 1 247 x 1 257 x1 257 x1
Weight
INDOOR UNITS
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB • Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor
Ambient Temp. 7°CDB / 6°CWB • Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
3. I.D : 'Internal Diameter' 4. LG Round cassette with black color panel is also available so LG Sales office can be contacted for further information.
KEY FEATURES
Note : 1. Due to our policy of innovation some specifications may be changed without notification. COMFORT AIR PURIFICATION KIT
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB With its 6-speed precision control technology and Smart Indicator
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB perfect round design, it offers comfortable cooling Color display by Air quality Severe Very Poor Poor Unhealthy Moderate Good
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
• Super High mode available for max 30 min. and will auto shift to previous mode for comfort operation. with natural airflow.
• Due to continuous improvement above function may be subjected to change without any prior notice. Step 4. Deodorization filter
LG Round Cassette
High efficiency gas adsorption technology removes life odor
& harmful gases
KEY FEATURES
Step 3. PM1.0 filter
Removes up to 99% of fine particle to ultrafine particle
6-STEP VANE CONTROL UP TO 700 (Able to remove PM 1.0)
Up & Down Step 2. Dust Electrification
The vertical vane, which moves up and down, has 6 different settings
70° 1
Anion increases the electrostatic force of particle & this
including full swing. Heating
2
3
Crystal Vane improves filter’s collecting efficiency
4
5
Step 1. Pre-filter
6 Multi layer structure removes particle 2.5 times higher efficiency PM1.0 Sensor
AUTO-CLEANING ※ Angle can be different from each model and working mode. than general pre-filters and particle is reduced by 40% ↑
Airflow Control 1 2 3 4 5 6
Its auto-cleaning innovative feature prevents bacteria, mold and odour formation ※ Normally HEPA filter type must be replaced regularly. It means that it costs expensive for maintenance.
in the indoor unit which allows the flow of air free from microbes.
30% FASTER IN COOLING PREMIUM DESIGN THAT COMPLETES YOUR SPACE
With greater airflow, it cools the room 30% faster Its elegant design stands out in any interior and fits perfectly in your
without missing a spot. space adding a dash of style. Its panels are styled with clean whites
LG Round Cassette and modern blacks, perfecting your interior.
PT-UQC PT-QCHW0
ARNU09GTRB4 / ARNU12GTRB4 Two Thermistor Control ○ ○ ○ ○
Group Control ○ ○ ○ ○
KEY FEATURES
ON / OFF MODE
The indoor unit automatically stops when detecting absence. It runs again when sensing human body. (Judgement time : 5 ~ 90min)
ARNU15GTQB4 / ARNU18GTQB4 Sensing human body Undetected Sensing human body Undetected ON OFF ON OFF
ARNU21GTQB4
5 step filteration
Note : 1. Due to our policy of innovation some specifications may be changed without notification. KEY APPLICATIONS
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
14 15
CEILING MOUNTED CASSETTE 2 WAY CASSETTE
4 WAY CASSETTE 840 X 840
JRNU09GTPA4 / JRNU12GTPA4
PT-MCGW0 PT-MPGW0 JRNU15GTPA4 / JRNU18GTPA4 ARNU09GTSC4 / ARNU12GTSC4
(For human detection) (For human detection and for air purification) JRNU24GTPA4 PT-USC ARNU18GTSC4 / ARNU24GTSC4
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
JRNU30GTPA4 / JRNU36GTNA4 / JRNU42GTMA4
JRNU48GTMA4 / JRNU54GTMA4
KEY FEATURES
KEY APPLICATIONS
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity. RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
16 • Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero. 17
Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200%
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
KEY FEATURES
KEY APPLICATIONS
RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT Comfort Cooling / Heating Comfort Cooling / Heating
18 19
UV NANO FILTER BOX
New
Model PBM13M1UA0
Conventional Unit
Applied Model ARNU07GM1A4 / ARNU09GM1A4 / ARNU12GM1A4 / ARNU15GM1A4 / ARNU18GM1A4 / ARNU24GM1A4
Net Size (W x H x D) mm 900 x 270 x 280
Shipping Size (W x H x D) mm 1,048 x 340 x 377
Net Weight kg 9.1
Shipping Weight kg 11.4
Size (W x H x D) mm 600 x 251 x 50.8
Quantity EA 1
Filter (1)
Grade 1 - ePM1 65%
1 step Grade 2 - MERV 13
Size (W x H x D) mm 250 x 251 x 50.8
High Static Pressure Setting Quantity EA 1
Filter (2)
Grade 1 - ePM1 65%
Grade 2 - MERV 13
Size (W x H x D) mm 596 x 247 x 4
Mesh - 34 x 39
Pre-Filter (1)
Color - Black
Quantity EA 1
Size (W x H x D) mm 247 x 247 x 4
OPERATION FOR MULTIPLE ROOMS MINIMISED HEIGHT Note : 1. Grade 1 : ISO EN 16890
2. Grade 2 : ASHRAE 52.5
Using a spiral duct (Embedded or Flexible type) and New low-static and high-static ducts provide ideal solution
stream chamber, it is possible to operate cooling / heating for installation in limited space.
for several rooms simultaneously.
LOW STATIC HIGH STATIC
190mm 270mm
KEY APPLICATIONS
HOTEL / CONFERENCE CENTER | RETAIL / SHOPPING CENTER | SCHOOL | OFFICE | RESTAURANT | CHURCH
HISTORIC BUILDING
20 21
HIGH STATIC DUCT FRESH AIR INTAKE UNIT
KEY FEATURES
JRNU28GBGA4 / JRNU36GBGA4 / JRNU42GBGA4 / JRNU48GBGA4
JRNU54GBRA4 / JRNU76GB8A4 / JRNU96GB8A4
FRESH OUTDOOR AIR SUPPLY
The LG Fresh Air Intake Unit (FAU) is the alternative solution for ventilation which supplies the fresh outdoor air to indoors as well as
being able to cool and heat the inside air simultaneously. It means the indoor space can have positive air pressure consistently which
can block cold, hot or contaminated air from outdoor.
MULTI V 5
Outdoor units Indoor Units Diffuser Indoor Units Diffuser Indoor Units Diffuser
Air Conditioning
Air Conditioning +
Outdoor Air Supply
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
22 23
FLOOR STANDING ERV WITH DX COIL
LZ-H050GXN4 / LZ-H080GXN4
ARUN48GPTA4 / ARNU96GPFA4
LZ-H100GXN4
Cooling Heating
Outdoor Return
KEY APPLICATIONS Air Air
FACTORY | RETAIL | SHOP | OFFICE | RESTAURANT
24 25
CONTROL SOLUTIONS
TYPES
� On/Off, Temperature Setting, Fan Speed, Auto Swing � 256 units, PC / Tablet & Remote Access
� Vane Angle Control, Reservation, Time Display � Device Interlocking, Priority & Capacity Control Mode
� Can Be Used for Duct Models Also (by using IR Accessory) � Operation History, Energy Management & Reporting
� BMS Compatible (BACnet/Modbus)
� 5 inch Touch Screen with Premium Design � Monitoring IDU Power Consumption through PDI
� Energy Management � 8 ODU Systems Can Be Configured with One PDI
� Yearly Scheduling, Group Control up to 16 IDU � Statistical Report Through Central Controller
� 32 Indoor Units, LCD Display � Connection Between IDU & External Devices to Control Various Functions
� Individual / Group Control � Key Tag, Fire Alarm, Motion / Lighting / Door Sensor
� Mode Change, Controller Lock � Interlocking with Open Protocol for Home Automation
� 64 units, 5 inch Touch Screen & Web Access. � System Air Conditioner Mobile App to Control
� Schedule Events, Error History, Remote Lock & Monitor the Device from Anytime and Anywhere
� Energy Save Mode, Emergency Stop � Compatible with iOS or Android Devices
� 128 units,10.2 inch Touch Screen, Dynamic UI � Cloud Based Building Solution
� Interlocking, Peak Control, Time Limit, Yearly Schedule � Facility Management System
� Energy Statistics, Operation Report, Emergency Stop Feature � Remote Access & Easy Control
� BMS Compatible (BACnet/Modbus) � Quick Service & Repair