You are on page 1of 14

DISCOVER THE

POWER OF THE MOST


ENERGY EFFICIENT
SYSTEM.

DUAL
SENSING
CONTROL
TEMPERATURE HUMIDITY
SENSOR SENSOR
ABOUT LG BENEFITS OF LG MULTI V
Ever since manufacturing of Korea’s first home grown air conditioner began in 1968, LG has remained at the forefront of air
BENEFITS FOR BUILDING OWNER
conditioning innovation. LG has not only been the leading manufacturer of top notch energy efficient solution provider, but also has
been amongst the top selling air conditioning brands globally.

With more and more focus on providing superior quality products, our team of experts work tirelessly to create solutions based on Efficient Management & Cost Reduction
latest technologies to provide faster and smarter solutions.

LG India through its world-class manufacturing facilities in Greater Noida & Pune, has been reaching out to its customers with its
comprehensive product portfolio that includes chillers, VRF systems, ducted splits, rooftop units, cassette units, floor standing units Reliability Guaranteed in Every Aspect
and building management systems (BMS).

The company also produces outstanding air conditioning professionals at its esteemed academies located in Delhi & Pune, India. It
Customised Comfort and Solution
has nearly 80 academies worldwide. These centres of excellence, provide workshops and training programs that offer invaluable
hands-on experience. LG also provides useful tools for HVAC system engineers and installers, including its time saving LG Air
Conditioner Technical Solutions (LATS) software.

BENEFITS FOR DEVELOPERS


GLOBAL PRESENCE / CONSTRUCTION COMPANIES

Green Solutions

Maximising Space Utilisation

INDIA
Smart Building Solutions

BENEFITS FOR CONSULTANTS

Versatile Solutions

Gr. Noida Factory Pune Factory Noida Innovation Gallery Pune Academy Bengaluru Academy

Professional Designing Support

Optimised Comfort in HVAC Designing

NABL CERTIFIED VRF TEST BED


BENEFITS FOR END-USERS

Operation Cost Saving


A fully automatic psychrometric lab in
compliance with AHRI / IS standards accredited by NABL .

Comfortable Cooling & Heating

HP Convenient Functions 16 18 20 22
Combination Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
Model Name
Independent Unit JRUV160LTE5 JRUV180LTE5
* Dual Sensing Smart JRUV200LTE5 JRUV220LTE5
Load Control based, below 50% humidity, model ARUN260LTE5

kW 44.8 50.4 56.0 61.6


2 Cooling kcal/h 38,500 43,300 48,200 53,000 3
Btu/h 152,900 172,000 191,100 210,200
Capacity (Rated)
kW - - - -
OUTDOOR UNITS LINE-UP
Unit : HP
Type Features Appearance 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 .... 104

● ● ● ●
■ ■ ■ ■

• Dual sensing control


• Large capacity ODU (Up to ● ● ● ● ● ●
26HP) ■ ■ ■ ■ ■ ■

• Black fin heat exchanger


• Ability to function as
● ● ● ● ● ● ● ● ● ● ● ●
MULTI V 5 heat pump ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
• Flexible installation with
large capacity in wide
operation range
● ● ● ● ● ● ● ● ● ● ● ●
• For large space, high rise ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
building and individual
control building
● ● ● ● ●
■ ■ ■ ■ ■

● ● ●
Compact ○ ○ ○
• Saves floor space
• Flexible design applications
- Slim, light and wide line up
MULTI V S (4 ~ 14HP) ● ● ●
- Combination of indoor unit
(Up to 23 Units)
• For small / medium building
□ □ ■

● ● ● ●

• High efficiency system


regardless external conditions
● ● ● ● ● ● ● ●
• Indoor installation product
MULTI V
• Low noise level
WATER IV
Heat Pump • For water sourced system,
high rise building and ● ● ● ● ● ●
aesthetic building
• For individual control building

● ● ● ● ● ●

MULTI V
WATER IV ■ ■ ■
Cooling only

● Heat Pump (H/P), 380V, 3Ø


○ Heat Pump (H/P), 220V, 1Ø
■ Cooling Only (C/O), 380V, 3Ø
□ Cooling Only (C/O), 220V, 1Ø

4 5
INDOOR UNITS LINE-UP INDOOR UNITS FEATURE OVERVIEW

Thermo Thermo Static Pressure 1 Point Auto


Occupied /
kW 1.5 2.2 2.8 3.6 4.5 5.6 6.2 7.1 8.2 9.0 10.6 12.3 14.1 15.8 22.4 28.0
Energy 2 Set Unoccupied Group Test Run Test Run
Model
Auto
Refrigerant On / Off On / Off 11 Step Control External Filter Sign Restart
Wi-Fi
Information Leakage Range Range (Only for Ceiling Input (Remaining Function
Monitoring Point Scheduling Control (Cooling) (Heating) Addressing Ready
Monitoring Detection Setting Setting Concealed (On / Off Time) Disable /
Type Btu/h 5k 7k 9k 12k 15k 18k 21k 24k 28k 30k 36k 42k 48k 54k 76k 96k Function
(Cooling) (Heating) Duct Type) Control) Enable

4th
generation
Standard ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ▲*
Wall
Mounted Unit

Round Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ●
(570 x 570)

4th
generation 4 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
Ceiling (840 x 840)
Mounted Unit

2 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

1 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

High Static ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th
generation
Ceiling
Concealed
Duct Low Static ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Fresh Air Intake Units

4th generation
Floor Standing ● ●
Floor Standing

Low Temperature ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4th generation
Hydro Kit

High Temperature ● ● ● ● ● ● ● ● ● ● ● ● ●

4th generation
Energy Recovery ● ● ● ● ● ● ●
without Humidifier ● ● ●
Ventilator with
DX Coil

* 30k, 36k model, Wi-Fi module is embedded


※ If 4th generation indoor units are combined to 2nd generation indoor units, several functions are not available.
More detailed information, refer to the "MULTI V Indoor units Compatibility Table"

6 7
MULTI V 5 SPECIFICATIONS

HIGH EFFICIENCY HEAT PUMP


JRUN080LTE5 / JRUN100LTE5
JRUN120LTE5 / JRUN140LTE5

HIGH EFFICIENCY HEAT PUMP


ARUN240LTE5 / ARUN260LTE5

HIGH EFFICIENCY HEAT PUMP

JRUN160LTE5 / JRUN180LTE5
JRUN200LTE5 / JRUN220LTE5

Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local
and national codes. And “Electric characteristics” chapter should
be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Therefore, these values can be increased owing to ambient conditions during operation. 4. Performances are based on the following conditions :
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor
Ambient Temp. 35°CDB / 24°CWB
• Interconnected Pipe Length is 7.5m and difference of
Elevation (Outdoor ~ Indoor Unit) is 0m.
5. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2,087.5)

8 9
Motor Output x Number W x No. 1,500 x 1 1,500 x 1 1,500 x 1 1,500 x 1
Fan Air Flow Rate (High) m3/min x No. 270 x 1 270 x 1 270 x 1 270 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Pipe Connections
Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127)
Dimensions (W x H x D) mm x No. (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1
Net Weight kg x No. 200 x 1 247 x 1 257 x1 257 x1
Weight
Shipping Weight kg x No. 208 x 1 255 x 1 265 x 1 265 x 1
HIGH EFFICIENCY COOLING ONLY Sound Pressure Level Cooling dB(A) 62.0 62.0 62.0 62.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
JRUV080LTE5 / JRUV100LTE5 Refrigerant Name R410A R410A R410A R410A
Refrigerant
JRUV120LTE5 / JRUV140LTE5 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of maximum connectable indoor units 26 (40) 29 (45) 32 (50) 35 (44)
HP 8 10 12 14 Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200%
Combination Unit JRUV080LTE5 JRUV100LTE5 JRUV120LTE5 JRUV140LTE5
Model Name
Independent Unit JRUV080LTE5 JRUV100LTE5 JRUV120LTE5 JRUV140LTE5
kW 22.4 28.0 33.6 39.2
Cooling kcal/h 19,300 24,100 28,900 33,700
Btu/h 76,400 95,500 114,600 133,800
Capacity (Rated)
kW - - - - HIGH EFFICIENCY COOLING ONLY
Heating kcal/h - - - -
Btu/h - - - -
Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray ARUV240LTE5 / ARUV260LTE5
Heat Exchanger Black Fin Black Fin Black Fin Black Fin
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll
Compressor Starting Method DC Inverter Starting DC Inverter Starting DC Inverter Starting DC Inverter Starting
Number of Compressor 1 1 1 1
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Axial Flow Fan HP 24 26
Motor Output x Number W x No. 900 x 1 900 x 1 900 x 1 900 x 1 Combination Unit ARUV240LTE5 ARUV260LTE5
Model Name
Fan Air Flow Rate (High) m3/min x No. 210 x 1 210 x 1 210 x 1 210 x 1 Independent Unit ARUV240LTE5 ARUV260LTE5
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
kW 67.2 72.8
Discharge Side / Top TOP TOP TOP TOP
Cooling kcal/h 57,800 62,600
Liquid Pipe mm (inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2)
Pipe Connections Btu/h 229,300 248,400
Gas Pipe mm (inch) 19.05 (3/4) 22.2 (7/8) 28.58 (1-1/8) 28.58 (1-1/8) Capacity (Rated)
kW - -
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127)
Heating kcal/h - -
Dimensions (W x H x D) mm x No. (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1 (920 x 1,680 x 760) x 1
Btu/h - -
Net Weight kg x No. 177 x 1 177 x 1 177 x 1 186 x 1
Weight Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Shipping Weight kg x No. 184 x 1 184 x 1 184 x 1 193 x 1
Heat Exchanger Black Fin Black Fin
Sound Pressure Level Cooling dB(A) 58.5 58.5 59.0 60.0
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll
mm x No.
2
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Compressor Starting Method DC Inverter Starting DC Inverter Starting
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Number of Compressor 2 2
Refrigerant Type Axial Flow Fan Axial Flow Fan
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Motor Output x Number W x No. 900 x 2 900 x 2
Number of maximum connectable indoor units 13 (20) 16 (25) 20 (30) 23 (35) Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1
Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200% Drive DC INVERTER DC INVERTER Note : 1. Due to our policy of innovation some specifications
Discharge Side / Top TOP TOP may be changed without notification.
Liquid Pipe mm (inch) 15.88 (5/8) 19.05 (3/4) 2. Wiring cable size must comply with the applicable local and
Pipe Connections national codes. And “Electric characteristics” chapter should
Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
be considered for electrical work and design.
Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) Especially the power cable and circuit breaker should be
HIGH EFFICIENCY COOLING ONLY Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 selected in accordance with that
3. Sound pressure level is measured on the rated condition in
Net Weight kg x No. 276 x 1 276 x 1
Weight the anechoic rooms by ISO 3745 standard.
Shipping Weight kg x No. 290 x 1 290 x 1
JRUV160LTE5 / JRUV180LTE5 Sound Pressure Level Cooling dB(A) 67.0 67.0
Therefore, these values can be increased owing to ambient
conditions during operation.
JRUV200LTE5 / JRUV220LTE5 mm2 x No. 4. Performances are based on the following conditions :
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) • Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB,
Refrigerant Name R410A R410A Outdoor Ambient Temp. 35°CDB / 24°CWB
Refrigerant • Interconnected Pipe Length is 7.5m and difference of
Control Electronic Expansion Valve Electronic Expansion Valve
Elevation (Outdoor ~ Indoor Unit) is 0m.
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50
HP 16 18 20 22 5. This product contains Fluorinated greenhouse gases.
Number of maximum connectable indoor units 39 (61) 42 (64) (R410A, GWP(Global warming potential) = 2,087.5)
Combination Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
Model Name Maximum Indoor Unit Combination Ratio* 200% 200% * The recommended ratio is 130%.
Independent Unit JRUV160LTE5 JRUV180LTE5 JRUV200LTE5 JRUV220LTE5
kW 44.8 50.4 56.0 61.6
Cooling kcal/h
Btu/h
38,500
152,900
43,300
172,000
48,200
191,100
53,000
210,200
KEY FEATURES
Capacity (Rated)
kW - - - -
Heating kcal/h - - - -
Btu/h - - - - ENERGY SAVING AND OPTIMISED HEAT EXCHANGER WITH BLACK FIN
Exterior Casing Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray COOLING THROUGH DUAL SENSING FOR CORROSION RESISTANCE
Heat Exchanger Black Fin Black Fin Black Fin Black Fin (TEMPERATURE AND HUMIDITY SENSOR)
Type LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll LG BLDC Inverter Scroll
Compressor Starting Method DC Inverter Starting DC Inverter Starting DC Inverter Starting DC Inverter Starting
Number of Compressor 1 2 2 2 LARGE CAPACITY OUTDOOR UNITS INCREASED AIR FLOW RATE
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Axial Flow Fan (SINGLE OUTDOOR UP TO 26 HP) WITH BIOMIMETICS FAN
Motor Output x Number W x No. 1,500 x 1 1,500 x 1 1,500 x 1 1,500 x 1
Fan Air Flow Rate (High) m3/min x No. 270 x 1 270 x 1 270 x 1 270 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
HIGH COMPRESSOR RELIABILITY
Discharge Side / Top TOP TOP TOP TOP AUTO DUST REMOVAL
Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) WITH OIL LEVEL SENSOR
Pipe Connections
Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
10 Operation Range Cooling °C (°F) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) -5 ~ 53 (23 ~ 127) 11
Dimensions (W x H x D) mm x No. (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1 (1,240 x 1,680 x 760) x 1
Net Weight kg x No. 200 x 1 247 x 1 257 x1 257 x1
Weight
INDOOR UNITS

WALL MOUNTED UNIT ROUND CASSETTE


JRNU09GSJA4 / JRNU12GSJA4 / JRNU15GSJA4 / JRNU18GSKA4 ARNU24GTYA4 / ARNU36GTYA4 / ARNU48GTYA4
JRNU24GSKA4 / ARNU30GSVA4 / ARNU36GSVA4

Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB • Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor
Ambient Temp. 7°CDB / 6°CWB • Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
3. I.D : 'Internal Diameter' 4. LG Round cassette with black color panel is also available so LG Sales office can be contacted for further information.

KEY FEATURES
Note : 1. Due to our policy of innovation some specifications may be changed without notification. COMFORT AIR PURIFICATION KIT
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB With its 6-speed precision control technology and Smart Indicator
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB perfect round design, it offers comfortable cooling Color display by Air quality Severe Very Poor Poor Unhealthy Moderate Good
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
• Super High mode available for max 30 min. and will auto shift to previous mode for comfort operation. with natural airflow.
• Due to continuous improvement above function may be subjected to change without any prior notice. Step 4. Deodorization filter
LG Round Cassette
High efficiency gas adsorption technology removes life odor
& harmful gases
KEY FEATURES
Step 3. PM1.0 filter
Removes up to 99% of fine particle to ultrafine particle
6-STEP VANE CONTROL UP TO 700 (Able to remove PM 1.0)
Up & Down Step 2. Dust Electrification
The vertical vane, which moves up and down, has 6 different settings
70° 1
Anion increases the electrostatic force of particle & this
including full swing. Heating
2
3
Crystal Vane improves filter’s collecting efficiency
4
5
Step 1. Pre-filter
6 Multi layer structure removes particle 2.5 times higher efficiency PM1.0 Sensor
AUTO-CLEANING ※ Angle can be different from each model and working mode. than general pre-filters and particle is reduced by 40% ↑
Airflow Control 1 2 3 4 5 6
Its auto-cleaning innovative feature prevents bacteria, mold and odour formation ※ Normally HEPA filter type must be replaced regularly. It means that it costs expensive for maintenance.
in the indoor unit which allows the flow of air free from microbes.
30% FASTER IN COOLING PREMIUM DESIGN THAT COMPLETES YOUR SPACE
With greater airflow, it cools the room 30% faster Its elegant design stands out in any interior and fits perfectly in your
without missing a spot. space adding a dash of style. Its panels are styled with clean whites
LG Round Cassette and modern blacks, perfecting your interior.

By dehumidifying, the The indoor environment By preventing polluting of the heat


auto cleaning function remains odourless with the exchanger caused by various germs and
eliminates substances advanced deodorising bacteria, the performance and life span of
that might be harmful. function. the air conditioner do not wither away
even after a period of 10 years.

Bacteria Odour Mold 12 minutes to reach the set temperature


Prevention Elimination Elimination

KEY APPLICATIONS KEY APPLICATIONS


RETAIL | RESTAURANT | OFFICE | HOTEL | RESIDENTIAL RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT
12 13
CEILING MOUNTED CASSETTE CEILING MOUNTED CASSETTE
4 WAY CASSETTE 570 X 570 HIGHLIGHTS OF 4 WAY, 2 WAY AND 1 WAY CASSETTE
Cassette 4 Way (570 x 570) 4 Way (840 x 840) 2 Way 1 Way
Smart Wi-Fi ○ ○ ○ ○
Panel Model Energy Efficiency Human Detection - ○ - -
Air Purification - ○ - ○
Health
Auto Cleaning - - ○ -
Drain Pump ○ ○ ○ ○
Sleep Mode ○ ○ ○ ○
Timer (On / Off) ○ ○ ○ ○
Comfort
ARNU05GTRB4 / ARNU07GTRB4 Timer (Weekly) ○ ○ ○ ○

PT-UQC PT-QCHW0
ARNU09GTRB4 / ARNU12GTRB4 Two Thermistor Control ○ ○ ○ ○
Group Control ○ ○ ○ ○

※ ○ : Applied, - : Not applied

KEY FEATURES

HUMAN DETECTION SENSOR


4 WAY CASSETTE (840 X 840) Human Detection Sensor
Panel Name (Accessory) - Saves energy
: PT-MCGW0 / PT-MPGW0 - Offers comfortable airflow
(For Human Detection) - Uses the sensor as an optional
accessory and can be applied to
PT-MCGW0, PT-MPGW0

Human Detection Sensor (PTVSMA0)

ON / OFF MODE
The indoor unit automatically stops when detecting absence. It runs again when sensing human body. (Judgement time : 5 ~ 90min)

Energy Energy Energy

ARNU15GTQB4 / ARNU18GTQB4 Sensing human body Undetected Sensing human body Undetected ON OFF ON OFF

ARNU21GTQB4

INDEPENDENT VANE CONTROL AIR PURIFICATION


The Independent Vane Operation feature uses separate motors, Air purification with filtration not only removes
making it possible to control all four vanes independently. upto 99.9% of PM 1.0 but also removes bacteria,
odour and ultra-fine dust particles, thus offering
Indirect air flow Direct air flow you a disease-free environment.

5 step filteration
Note : 1. Due to our policy of innovation some specifications may be changed without notification. KEY APPLICATIONS
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
14 15
CEILING MOUNTED CASSETTE 2 WAY CASSETTE
4 WAY CASSETTE 840 X 840

Panel Model Panel Model

※ Human detection and


air purification kit
need to be purchased
additionally

JRNU09GTPA4 / JRNU12GTPA4
PT-MCGW0 PT-MPGW0 JRNU15GTPA4 / JRNU18GTPA4 ARNU09GTSC4 / ARNU12GTSC4
(For human detection) (For human detection and for air purification) JRNU24GTPA4 PT-USC ARNU18GTSC4 / ARNU24GTSC4

Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
JRNU30GTPA4 / JRNU36GTNA4 / JRNU42GTMA4
JRNU48GTMA4 / JRNU54GTMA4
KEY FEATURES

6-STEP VANE CONTROL


The Independent Vane Operation feature uses separate motors, making it possible to control all four vanes independently.
There are 6 different steps to control air flow direction. Also, 1 Way Cassette has a vane control mechanism that helps to auto swing
between left and right at 120 degree.

Up and Down (6 step)


20°
20˚
20 °
30 ° Adjustable
40 ° Vane
50 ° 70°
60 °
70 °
70˚

KEY APPLICATIONS
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity. RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
16 • Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero. 17
Maximum Indoor Unit Combination Ratio* 200% 200% 200% 200%

1 WAY CASSETTE CEILING CONCEALED DUCT

ARNU07GTUB4 / ARNU09GTUB4 / ARNU12GTUB4


ARNU18GTTB4 / ARNU24GTTB4
HIGHLIGHTS OF HIGH AND LOW STATIC DUCT
Duct High Low
Smart Wi-Fi ○ ○
For ARNU - GTUB4 (860 x 450) For ARNU - GTTB4 (1,180 x 450) Energy Efficiency E.S.P. Control ○ ○
Drain Pump ○ ○
Timer (On / Off) ○ ○
Comfort Timer (Weekly) ○ ○
Two Thermistor Control ○ ○
Group Control ○ ○

※ ○ : Applied, - : Not applied


PT-UAHW0 PT-UAHG0 PT-TAHW0 PT-TAHG0
(Glossy, For Air Purification) (Glossy, For Air Purification)

LOW STATIC DUCT

JRNU09GL5G4 / JRNU12GL5G4 / JRNU15GL5G4


JRNU18GL5G4 / JRNU24GL6G4

Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.

KEY FEATURES

MINIMISED HEIGHT AIR PURIFICATION


Note : 1. Due to our policy of innovation some specifications may be changed without notification.
1 Way Cassette isn’t affected by installation environment. 2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
The height of 1 Way Cassette is 132mm and duct size is 190mm AIR-PURIFYING FILTER THAT REMOVES UPTO • Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
99.9% OF PM1.0 • Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
and can be ideal fit solution for installation in limited space. • Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.

132mm EASY MAINTENANCE WITH WASHABLE


KEY FEATURES
FILTERS
E.S.P (EXTERNAL STATIC PRESSURE) CONTROL
User has an easy access to air volume selection via remote controller secured by the E.S.P control function. The BLDC motor can
6 COLOURED LED INDICATION FOR AQI control fan speed and air volume regardless of the external static pressure. No additional accessories are necessary to control the air flow.
(AIR QUALITY INDEX)
Size Comparison (Unit : mm)

A company B company LG E.S.P Control E.S.P Control


1 Way REMOVES MORE THAN 99% OF ULTRA-FINE
Cassette 215 230 132
DUST PARTICLES, BACTERIA AND VIRUS

KEY APPLICATIONS
RETAIL | SCHOOL | OFFICE | HOTEL | DORMITORY | RESTAURANT Comfort Cooling / Heating Comfort Cooling / Heating

18 19
UV NANO FILTER BOX

STATIC PRESSURE 11 STEPS CONTROL


Depending on the installation environment, 4 series ceiling concealed duct is controlled the static pressure to 11 step, for providing
comfortable environment suitable for any case scenario.
PBM13M1UA0

New
Model PBM13M1UA0
Conventional Unit
Applied Model ARNU07GM1A4 / ARNU09GM1A4 / ARNU12GM1A4 / ARNU15GM1A4 / ARNU18GM1A4 / ARNU24GM1A4
Net Size (W x H x D) mm 900 x 270 x 280
Shipping Size (W x H x D) mm 1,048 x 340 x 377
Net Weight kg 9.1
Shipping Weight kg 11.4
Size (W x H x D) mm 600 x 251 x 50.8
Quantity EA 1
Filter (1)
Grade 1 - ePM1 65%
1 step Grade 2 - MERV 13
Size (W x H x D) mm 250 x 251 x 50.8
High Static Pressure Setting Quantity EA 1
Filter (2)
Grade 1 - ePM1 65%
Grade 2 - MERV 13
Size (W x H x D) mm 596 x 247 x 4
Mesh - 34 x 39
Pre-Filter (1)
Color - Black
Quantity EA 1
Size (W x H x D) mm 247 x 247 x 4

11 steps Pre-Filter (2)


Mesh - 34 x 39
Color - Black

Low Static Power Setting Quantity EA 1


LED Quantity EA 8
UVnano Input V DC 12V
Wavelenght mm 275

OPERATION FOR MULTIPLE ROOMS MINIMISED HEIGHT Note : 1. Grade 1 : ISO EN 16890
2. Grade 2 : ASHRAE 52.5

Using a spiral duct (Embedded or Flexible type) and New low-static and high-static ducts provide ideal solution
stream chamber, it is possible to operate cooling / heating for installation in limited space.
for several rooms simultaneously.
LOW STATIC HIGH STATIC

190mm 270mm

FLEXIBLE INSTALLATION (LOW STATIC DUCT ONLY)


The low static duct allows the air intake at the rear or bottom under installation condition. Air intake at the rear or bottom

KEY APPLICATIONS
HOTEL / CONFERENCE CENTER | RETAIL / SHOPPING CENTER | SCHOOL | OFFICE | RESTAURANT | CHURCH
HISTORIC BUILDING

20 21
HIGH STATIC DUCT FRESH AIR INTAKE UNIT

ARNU07GM1A4 / ARNU09GM1A4 / ARNU12GM1A4


ARNU76GB8Z4 / ARNU96GB8Z4
ARNU15GM1A4 / ARNU18GM1A4 / ARNU24GM1A4

Note : 1. Capacities are based on the following conditions.


• Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Outdoor temp. 35°C (95°F) DB / 24°C (75.2°F) WB, Interconnecting piping length 7.5m, Level
difference of zero
• Heating : Indoor temp. 20°C (68°F) DB / 15°C (59°F) WB, Outdoor temp. 7°C (44.6°F) DB / 6°C (42.8°F) WB, Interconnecting piping length 7.5m, Level
difference of zero
2. Due to our policy of innovation, some specifications may be changed without notification.

KEY FEATURES
JRNU28GBGA4 / JRNU36GBGA4 / JRNU42GBGA4 / JRNU48GBGA4
JRNU54GBRA4 / JRNU76GB8A4 / JRNU96GB8A4
FRESH OUTDOOR AIR SUPPLY

The LG Fresh Air Intake Unit (FAU) is the alternative solution for ventilation which supplies the fresh outdoor air to indoors as well as
being able to cool and heat the inside air simultaneously. It means the indoor space can have positive air pressure consistently which
can block cold, hot or contaminated air from outdoor.

100% Fresh Air Intake Unit


Outdoor Air

MULTI V 5
Outdoor units Indoor Units Diffuser Indoor Units Diffuser Indoor Units Diffuser

Air Conditioning
Air Conditioning +
Outdoor Air Supply

ECONOMIC OPERATION Spring Season Autumn Season


Fresh Air Intake Unit Fresh Air Intake Unit

Using the cooling and heating can


MULTI V 5 MULTI V 5
save cost by blowing the natural Outdoor units Indoor Unit Diffuser Outdoor units Indoor Unit Diffuser
OFF OFF
outdoor air inside when the
Warm Air Cool Air
season changes. + +
Outdoor Air Supply Outdoor Air Supply

Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.

22 23
FLOOR STANDING ERV WITH DX COIL

LZ-H050GXN4 / LZ-H080GXN4
ARUN48GPTA4 / ARNU96GPFA4
LZ-H100GXN4

Model Unit LZ-H050GXN4 LZ-H080GXN4 LZ-H100GXN4


Fresh Air Cooling (Coil) kW 4.93 (3.7) 7.46 (5.6) 9.12 (6.6)
Conditioning Load Heating (Coil) kW 6.73 (3.7) 9.80 (5.6) 11.72 (6.6)
Temperature
SH / H / L % 86 / 86 / 87 80 / 80 / 81 76 / 76 / 78
Exchange Efficiency
Enthalpy Exchange Cooling (SH / H / L) % 61 / 61 / 63 50 / 50 / 53 45 / 45 / 50
Efficiency Heating (SH / H / L) % 76 / 76 / 77 67 / 67 / 69 64 / 64 / 66
Operation Range Outdoor air Temperature °C -15 ~ 45 -15 ~ 45 -15 ~ 45
Heat Exchange Mode (SH / H / L) CMH 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820
Air Flow Rate
Bypass Mode (SH / H / L) CMH 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820
Fan External Static Pressure (SH / H / L) Pa 180 / 150 / 110 170 / 120 / 80 150 / 100 / 70
Heat Exchange Mode (SH / H / L) dB(A) 39 / 37 / 35 41 / 38 / 36 41 / 39 / 36
Sound Pressure
Bypass Mode (SH / H / L) dB(A) 39 / 37 / 35 41 / 38 / 36 41 / 39 / 36
Refrigerant R410A
Power Supply Ø, V, Hz 1, 220-240, 50 / 60
Air to air cross flow total heat
Heat Exchange System
(Sensible + Latent heat) exchange
Heat Exchange Element Specially processed non-flammable paper
Air Filter Multidirectional fibrous fleeces
Dimensions WxHxD mm 1,667 x 365 x 1,140
Net Weight kg 98
Liquid mm 6.35
Gas mm 12.7
Piping Connection
Water mm -
Drain Pipe (Internal Dia.) mm (inch) 25 (1)
Note : 1. Due to our policy of innovation some specifications may be changed without notification. Connection Duct Diameter mm 250
2. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero. KEY FEATURES

PROVIDING COOL & WARM FRESH AIR


KEY FEATURES
During the summer, ERV DX can transform outdoor warm air into cool air for indoors, and it can prevent cold drafts during the
winter by supplying warm air.
SIMPLE & ELEGANT DESIGN 15M LONG POWER COOLING
With its stylish design, LG’s new floor standing The new LG floor standing unit is efficient for using in large
air conditioner enhances the overall indoor interior. areas due to its powerful cooling and heating operation.
The powerful air speed and volume means the air flow can
reach up to 15m away from the air conditioner.

Cooling Heating

TOTAL AIR CONDITIONING SOLUTION


※ Based on 131.8m2 Type Floor Standing Heat Exchange DX Coil
Air Flow (m3/min) 68
LG ERV DX can be used as a Total Air
Conditioning Solution. It can control condition
of incoming air with the DX coil for making
comfortable indoor air. Exhaust Supply
Air Air

Outdoor Return
KEY APPLICATIONS Air Air
FACTORY | RETAIL | SHOP | OFFICE | RESTAURANT

24 25
CONTROL SOLUTIONS
TYPES

WIRELESS REMOTE ACP 5

� On/Off, Temperature Setting, Fan Speed, Auto Swing � 256 units, PC / Tablet & Remote Access
� Vane Angle Control, Reservation, Time Display � Device Interlocking, Priority & Capacity Control Mode
� Can Be Used for Duct Models Also (by using IR Accessory) � Operation History, Energy Management & Reporting
� BMS Compatible (BACnet/Modbus)

SIMPLE WIRED REMOTE CONTROLLER AC MANAGER 5

� On/Off, Temperature Setting � 8192 Units, PC Software for Integrated Management.


� Fan Speed, Mode Change � Power Consumption Monitoring, Visual Navigation
� Interlocking, Virtual Group Control

STANDARD III WIRED REMOTE BMS GATEWAY

� Humidity Sensor Embedded � Interface b/w BMS & LG Air Conditioner


� Human Detection Feature � Supports LonWorks Protocols
� Air Quality Monitoring � Backup Controller in Case of BMS Failure

PREMIUM REMOTE POWER DISTRIBUTION INDICATOR (PDI PREMIUM)

� 5 inch Touch Screen with Premium Design � Monitoring IDU Power Consumption through PDI
� Energy Management � 8 ODU Systems Can Be Configured with One PDI
� Yearly Scheduling, Group Control up to 16 IDU � Statistical Report Through Central Controller

AC EZ INTEGRATION DEVICE (DRY CONTACT)

� 32 Indoor Units, LCD Display � Connection Between IDU & External Devices to Control Various Functions
� Individual / Group Control � Key Tag, Fire Alarm, Motion / Lighting / Door Sensor
� Mode Change, Controller Lock � Interlocking with Open Protocol for Home Automation

AC EZ TOUCH SMART SOLUTION

� 64 units, 5 inch Touch Screen & Web Access. � System Air Conditioner Mobile App to Control
� Schedule Events, Error History, Remote Lock & Monitor the Device from Anytime and Anywhere
� Energy Save Mode, Emergency Stop � Compatible with iOS or Android Devices

AC SMART 5 TOTAL MANAGEMENT SYSTEM

� 128 units,10.2 inch Touch Screen, Dynamic UI � Cloud Based Building Solution
� Interlocking, Peak Control, Time Limit, Yearly Schedule � Facility Management System
� Energy Statistics, Operation Report, Emergency Stop Feature � Remote Access & Easy Control
� BMS Compatible (BACnet/Modbus) � Quick Service & Repair
26 27

You might also like