Professional Documents
Culture Documents
Broșură BSK Scholar
Broșură BSK Scholar
www.bskhvac.com.tr
CONTENTS
02
Device General Information
03
Working Principle
04
Technical Details
07
Graphs
06
Device Dimensions
01
Device General Information
BSK SCHOLAR
CLASSROOM TYPE HEAT RECOVERY DEVICE
General Information
Classrooms
Meeting Rooms
2IͤFHV
%6.6FKRODUKLJKHIͤFLHQF\KHDW
recovery devices are specially designed
for classrooms, meeting rooms or
RIͤFHVZLWKRXWH[LVWLQJYHQWLODWLRQ
systems.
High capacity
air flow
%100
Fresh Air
7KDQNVWRWKHKLJKO\HIͤFLHQF\FRXQWHU
flow heat exchanger inside, the heat
energy of the exhausted air is used to
heat up the fresh air taken from outside.
No energy is wasted for this passive
heating process. In this way, you can
VLJQLͤFDQWO\GHFUHDVH\RXUKHDWLQJFRVWV
against conventional ventilation meth-
ods.
02
General Information Technical Details Dimensions Graphs
WORKING PRINCIPLE
Fresh air in
Exhaust air in
Exhaust air in
Fresh air in
03
Technical Details
TECHNICAL DETAILS
AIR DAMPER
FILTERS
HIGH EFFICIENCY
HEAT EXCHANGER
SILENCER
04
General Information Technical Details Dimensions Graphs
TECHNICAL DETAILS
7KHFDVLQJRIRXUGHYLFHVLVGRXEOHZDOOHGPPJDOYDQL]HGVKHHWVͤOOHGZLWKPPURFNZRROLQVXODWLRQPDWHULDOLQRUGHUWR
keep the sound and heat insulation at the highest level. The outside as well as the inside surfaces of our devices are painted
with electrostatic powder paint and deliver a long life, while providing a stylish and clean appearance.
2 FILTERS
7RWDORIͤOWHUVDUHXVHGLQRXU
GHYLFHVWRͤOWHUERWKWKHVXSSO\
DQGH[KDXVWDLU0ͤOWHULVXVHG
RQWKHH[KDXVWDLUWRͤOWHUGXVW
and protect the inside of the
GHYLFH*DQG)ͤOWHUVXVHGRQ
the fresh air side can stop
particles up to 1 micron
PP DQGͤOWHUDOOHUJHQV
such as dust, spores and pollen
that may come from outside. In
DGGLWLRQZKHQWKHͤOWHUVUHDFKD
FHUWDLQͤOOLQJUDWHRXUGHYLFHV
JLYHDQDXWRPDWLFͤOWHUIXOO
warning, thanks to the differential
pressure sensors that detect the
SUHVVXUHEXLOGXSRIͤOWHUV
05
Dimensions
DEVICE DIMENSIONS
E G H B
A
F
D
C
A B C D E F G H
Scholar 500 575 780 1650 160 55 130 235 417
Scholar 700 625 780 1650 180 55 130 225 417
The outside air inlet and outlet of our devices are designed to be easily used in any application area and easily changed in order
to suit different connection needs. You can lean the device in front of a window or wall and connect directly from the back, or
change the position of the air outlets so that the connection can be made from the top.
06
General Information Technical Details Dimensions Graphs
PERFORMANCE GRAPH
100
90
80
70
Fan level (%)
60
BSK Scholar 500 50
40
30
20
10
0
0 50 100 150 200 250 300 350 400 450 500
Air Ňow (m3/h)
100
90
80
70
Fan level (%)
60
50
BSK Scholar 700
40
30
20
10
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Air Ňow (m3/h)
07
Graphs
100
95
90
Thermal eī. (%)
80
75
70
0 50 100 150 200 250 300 350 400 450 500
Air Ňow (m3/h)
100
95
90
Thermal eī. (%)
85
BSK Scholar 700
80
75
70
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Air Ňow (m3/h)
08