You are on page 1of 1

20.07.

2023 Structural analysis SSI-Schäfer-Noell


Ketterer

Project: 1 977 180 Tambasa - Contagem Position: Lift 3


responsible person: Ketterer
1. Structural system
Coordinate system y
map.
x
z
on floor

totoal height 19,38 m


fixing height 16,03 m
2'nd fixing heigt 0 m
3'rd fixing heigt 0 m

2. Loads
load force
Load 2400 kg 24,0 kN
lift carriage incl. conveyor system 2100 kg 21,0 kN
ballance weight 3300 kg 33,0 kN

lift (uprights, motor, …) 7700 kg 77,0 kN


Vorspannkraft der Riemen ca. 1,2 x Fmax (aller Riemen) = 73,7 kN

Emergency case ( safety catch) max. accelleration= - m/s²


(Thyssen max 20m/s² - average 16 m/s²)

3. Calculation

Hublastbeiwert (Schwingbeiwert) excelleration 1,5 m/s²


speed 120 m/min
Nominal load spectrum factor= 1,364 [-]
(DIN 15018) inclination 0,02 [-]

Support forces (characteristic forces)


The values are the resulting forces for diffrent load situation.
It is not allowed / necessary to summate the values.
x- direction - 1'st fixing height 16,03
horizontal forces Sum each upright
min. static force 2,1 kN 1,1 kN
max static force 3,8 kN 1,9 kN
max. dynamical force 4,6 kN 2,3 kN

y-direction 1'st fixing height 16,03


horizontal forces (direction of load flow) Sum each upright
dynamical force 3,4 kN 1,7 kN

z-direction ground floor 0,00


vertical forces Sum each upright
max. static force 155,0 kN 77,5 kN
max. dynamical force 183,4 kN 91,7 kN

2023-07-SLH-II_a(deut_engl)_Lift_3.xls