FOOTING ANALYSIS
In accordance with ACI318-19
Tedds calculation version 3.3.02
Summary results
Description Unit Applied Resisting FoS Result
Uplift verification kN 100.3 Pass
Overturning stability, x kNm 2 -60.3 30.61 Pass
Overturning stability, y kNm -1.7 60.7 35.47 Pass
Description Unit Applied Resisting Utilization Result
Applied Resisting UR
Soil properties
Gross allowable bearing pressure; qallow_Gross = 216 kN/m2;
Density of soil; soil = 17.2 kN/m3
Angle of internal friction; b = 30.0 deg
Design base friction angle; bb = 30.0 deg
Coefficient of base friction; tan(bb) = 0.577
Design wall friction angle; b = 15.0 deg
Passive pressure coefficient (Coulomb); KP = sin(90 - b)2 / (sin(90 + b) [1 - [sin(b + b) sin(b) / (sin(90 +
b))]]2) = 4.977
Footing loads
Dead surcharge load; FDsur = 10.0 kN/m2
Live surcharge load; FLsur = 10.0 kN/m2
Self weight; Fswt = h conc = 10.8 kN/m2
Soil weight; Fsoil = hsoil soil = 18.1 kN/m2
Uplift verification
Vertical force; Fdz = 100.3 kN
PASS - Footing is not subject to uplift