You are on page 1of 2

Data Sheet

Special Medium Voltage Reeling Cable


with FO Elements 3.6/6 kV
Cable Type: NTSCGEWÖU HELUKABEL
3 x 70 + 50 + 3 x (4x2.5)C mm² + 18FO 62.5/125 Part.-No.: 17 . . . . . .

Technical Data

Construction:
- Conductors:
Electrolytic, tinned annealed bare stranded copper conductors
according to EN 60228 class 5
- Insulation: EPR Compound type 3GI3
- Electrical field control: Inner and outer layer of semi-conductive
rubber compound, easily strippable
- Optical fibre elements:
° Thixotropic jelly filled loss tube PBT,
contains thixotropic jelly as filler for each loose tube
° Optical fibre 62.5/125 SM
° Tube colour: red, yellow, green, blue, violet, white
° Fibre colour: red, yellow, natural
- Assembly:
° Control cores twisted into quads.
° Each quad screened with tinned copper wire braiding.
° Three cores 70 mm² and one core 50 mm² twisted in a layer
with quads and fibre optic elements in the outer interstices
- Inner sheath: Elastomer compound type GM1b
- Sheath reinforcement: Textile braiding, embedded in the sheath
- Outer sheath: Elastomer Compound type 5GM5
- Colour of outer sheath: red
- Outer diameter approx. 65.1 mm +/- 5%

Electrical parameters:
- Nominal voltage: 3.6/6 kV
- Max. permissible operating voltage: 4.2/7.2 kV AC
- Max. permissible operating voltage: 5.4/10.8 kV DC
- Test Voltage: 11 kV AC

Mechanical parameters:
-
Min. bending radius: Generally to DIN VDE 0298 part 3
-
Min. distance with S-type
directional changes: 20 x D

Copyright© HELUKABEL GmbH


Errors / technical modifications excepted (N)STSCGEWOEU 3x70+50+3x(4x2,5)C+18FO 62,5-125 3,6-6kV
engl.docx
Data Sheet

Temperature range:
- Max. conductor operating temperature: +90°C
- Max. conductor temperature during short circuit +250°C
- Min. ambient temperature for fixed installations: -40°C
- Max. ambient temperature for fixed installations: 85°C
- Min. ambient temperature in fully flexible operation: -35°C
- Max. ambient temperature in fully flexible operation: -85°C

Properties:
- Resistance to fire: EN 60332-1-2, IEC 60332-1-2
- Resistance to oil: EN 60811-404, IEC 60811-404
- Weather resistance: outdoors and indoors,
resistant to ozone and moisture

Cable weight: approx. 6.800 kg / km

1 New 2020-09-16 Schmitz


Edition Changes Date Name

Copyright© HELUKABEL GmbH


Errors / technical modifications excepted (N)STSCGEWOEU 3x70+50+3x(4x2,5)C+18FO 62,5-125 3,6-6kV
engl.docx

You might also like