You are on page 1of 3

SOUTH WEST GAS FIELDS DEVELOPMENT PROJECT, ALGERIA

Realization of Gas Treatment Units (EPC 2 – Phase 1)

DOCUMENT NAME : PUMP PERFORMANCE CURVE of Diesel Distribution


Pumps ( 1440-PA-62-001 A/B) for HBH
DATE : 19-03-2020
JOB CODE :
SWGFD CA DOCUMENT NO : 11EPG18-1CPF-DD-MR-00 PA 152
PAGE NO: 1 of 3
LTHE DOCUMENT NO : V-2158-005-152

PROJECT NAME : SOUTH WEST GAS FIELDS DEVELOPMENT PROJECT, ALGERIA


Realization of Gas Treatment Units (EPC 2 – Phase 1)
COMPANY NAME : Sonatrach, Algeria
CONTRACT No. : CT-EPC/011/SH-EPM/EP-G/18
CONTRACTOR : L&T Hydrocarbon Engineering (LTHE)
SUPPLIER : Kirloskar Ebara Pumps Limited
P.O. NUMBER : Refinery/75000-60904/DJD
EQUIPMENT TAG : 1440-PA-62-001 A/B
EQUIPMENT TITLE : Diesel Distribution Pump (HBH)
SUPPLIER DOCUMENT NUMBER : PPC501007110010100
ISSUE DATE CLOSED DATE RETURN CODE
DOCUMENT CA REVIEW STATUS
SUBMISSION STATUS
LTHE REVIEW STATUS 08-APR-20 CODE-A
DOC. CATEGORY: (USE TICK MARK)
DISCIPLINE NAME E-SIGN
A R I
ME- ROTARY AA
DELIVERABLE REVIEW LEVELS

A - Issued for Approval (IFA)


This is the highest level of review reserved for high impact deliverables or those which may
result in financial commitment (e.g. requisitions, work scope etc.). At this level, the reviewer
must take great care to ensure that the deliverable is indeed correct. Only one person will
actually approve a Deliverable and by signing it off the reviewer will be accountable for the
technical content of the deliverable. The design process will be on hold until approval is
granted. The CA engineer collates all the comments and returns them to the originator
 No approval = DESIGN STAYS ON HOLD

R - Issued for Review (IFR)


This is one step up the review ladder and the reviewer is expected to take the time to
thoroughly review the deliverable. The design process will be on hold for the comment
period. Project engineer collates all the comments at the end and returns them to the
originator.
 No Response Within the comment Period = DESIGN PROCESS CONTINUES

I - Issued for Information (IFI)


Documents issued for Information have in many cases been issued to assist with the review
of other documents and for general awareness of what is proposed. Review of the
documents need not necessarily be required and failure to review will impede the design
process by the design contractor.
 No Response = No comment
REVIEW RETURN CODES
[CODE A] FINAL
Document accepted. Do not re-submit except modified
[CODE B] REVISE AND RE-ISSUE (RE-SUBMIT)
Incorporate comments and re-issue for review. Work may proceed.
[CODE C] REVIEW NOT REQUIRED (NOT TO RE-SUBMIT)
Incorporate comments and proceed. Do not re-issue for review
[CODE D] REJECTED.
Incorporate comments and re-issue for review. Work may( shall ) NOT proceed

1 Issued for Approval AG YT MK 19-03-2020


0 Issued for Approval AG YT MK 07-11-2019
Rev. Description Prepared By Reviewed Approved By Approved Date

ALL RIGHTS RESERVED


THIS DOCUMENT IS DEVELOPED BY LTHE AND INFORMATION CONTAINED IS PROPERTY OF SONATRACH DIRECTION CENTRALE – EPM. IT SHALL NOT BE USED FOR ANY PURPOSE
OTHER THAN FOR WHICH IT WAS SUPPLIED, CONFIDENTIAL - NOT TO BE DISCLOSED WITHOUT AUTHORIZATION
SOUTH WEST GAS FIELDS DEVELOPMENT PROJECT, ALGERIA
Realization of Gas Treatment Units (EPC 2 – Phase 1)

DOCUMENT NAME : PUMP PERFORMANCE CURVE of Diesel Distribution


Pumps ( 1440-PA-62-001 A/B) for HBH
DATE : 19-03-2020
JOB CODE :
SWGFD CA DOCUMENT NO : 11EPG18-1CPF-DD-MR-00 PA 152
PAGE NO: 2 of 3
LTHE DOCUMENT NO : V-2158-005-152

By

ISSUE RECORD / REVISION HISTORY

Rev. Date Section/Pages Description

0 07-11-2019 Issued for Approval


1 19-03-2020 Issued for Approval

ALL RIGHTS RESERVED


THIS DOCUMENT IS DEVELOPED BY LTHE AND INFORMATION CONTAINED IS PROPERTY OF SONATRACH DIRECTION CENTRALE – EPM. IT SHALL NOT BE USED FOR ANY PURPOSE
OTHER THAN FOR WHICH IT WAS SUPPLIED, CONFIDENTIAL - NOT TO BE DISCLOSED WITHOUT AUTHORIZATION
Pump Performance Curve
MCF of 4 m3/hr added to rated flow.
6.0

Power - kW 4.5
Power
3.0

1.5

0.0

80 100
Minimum Continuous Safe Flow (MCSF)
72 90
214 mm

64 80

56 70

Efficiency - %
48 60
Head - m

194 mm

40 50

32 40
185 mm

24 Efficiency 30

16 20

8 10

0 0
NPSHr - m

3.0 NPSHr

1.5

0.0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Flow - m3/h
Customer : L&T Hydrocarbon Engineering Vadodara Pump Size/ Stages : 50 x 40 KESS 20A/ 1 Flow, rated : 11.00 m3/h
Customer enquiry : Sonatrach Algeria Speed, rated : 2900 rpm Differential Head : 38.00 m
Project : Sonatrach Based on curve number : 5040KESS20A1920 Fluid density : 0.800-0.850 SG 1

Quote number : 332008 Viscosity : 15.00 cP Efficiency : 33.2 %


Item number : 1440-PA-62-001 A/B Cq/Ch/Ce/Cn [HI2004] : 0.96 / 0.97 / 0.80 / 1.00 Power, rated : 3.1 kW
Quantity :2 Minimum recommended driver rating : 5.50 kW / 7.38 hp NPSH required : 1.3 m
Date last saved : 19 Mar 2020 07:12 PM Performance testing standard : API 610 Liquid Type/ Application : Diesel 1

1) Allowable Operating Range: 4 m3/hr to 15.7 m3/hr


2) Preferred Operating Range: 9.2 m3/hr to 15.7 m3/hr. 1

You might also like