You are on page 1of 6
Part-1 1) As the diameter of probe increases, The beam spread angle a) Decreases b) increases ¢) Remains same d) Depends on the damping 2) At a given location during normal beam examination of plate, itis observed that the amplitude of flaw is 80% full screen (FSH) while that of backwall is 10 % FSH in terms of dB the amplitude difference between these two signals will be : a)8dB b) 16 dB ¢) 188 d) Backwall signal cannot be less than the defect signal, 3) Interface trigger control is generally used dur a) Contact pulse echo testing b) Contact through transmission testing ¢) Immersion pulse echo testing d) Contact tandem technique 4) High PRF may be required when : a) High penetration of sound is required during examination of thick sections b) High sensitivity is required for detection of small flaws ¢) High resolution is required for detection of flaws close to the scanning surface d) The speed of examination is high 5) Delay probes are generally used on a) Thin materials b) Very thick materials ) Highly attenuating materials d) Materials, where thickness is more than the near field 6) The unique feature of normal beam dual crystal probes is that : a) The near field is completely eliminated b) They should be used on thicknesses that falls within the effective range of the probe c) They should used on thicknesses that fall beyond the effective range of the probe d) Dead zone is completely eliminated e) (b) and (A) 7) When an angle beam probe is placed facing 25 mm radius on 1 V2 block, the 4" signal after the initial pulse corresponds to the metal path of: a) 175 ram b) 225 mm 250 mm d) 275 mm 8) Which of the Following statements) is are/true a) V2 block can be used for determination cat beam index point of angle beam probes b) V2 block can be used for calibration of range using angle beam probe €) V2 block can be used for accurate determination of angle as compared to VI block cl) All of the above e) (a) and (b) 9) Ability of ultrasonic test system to detect the smallest flaw in the material is Called: a) Resolution b) Dead zone ¢) Nearfield 4d) Sensitivity 10) The given ultrasonic test system can measure thickness of very thin plate if : a) It's sensitivity is very high b) it's near surface resolution is very good It's near field length is very low i) it's dead zone is very high 11)Damping the piezooleetrle crystal a) Reduced dead zone enhances sensitivity and penetration b) increases dead zone and reduces sensitivity penetration c) have no effect on dead zone but improve sensitivity penetration 4) have no effect zone but reduces sensitivity and penetration. e) reduces dead zone and reduces sensitivity and penetration 12) during examination of 40 mm thick single vee butt weld by 45 deg. Sher wave probe an at a metal path of 80m mm. at the probe location the distance between the weld Centre line a) 50 mm from the weld center line towards in the probe ) 50 mm from the weld center line away from the probe c) 6 mm from the weld cent-re-line away from the probe 4) 6mm from the weld center-line towards the probe 13) during angle beam examination of a 25 mm thick steel plate using 60 deg. Sher wave probe an indication is observed at a beam path of 70 mm. the depth of indication the scanning surface : a) 10 mm b) 11mm ¢)15mm d) 25 mm, 14) which of the following beam angles is/ are suitable for complete coverage while carrying out circumferential angel beam examination from outside surface Foer a pipe having 80 mm od and 60 mm id: a) 35 deg b) 45 deg. ¢) 60 deg d) all of the above e) (a) and (b) 15) The advantage of pulse -echo technique over through-transmission technique is that: a) it needs access to only one surface of the component. b) it can find out the depth of the flaw from the scanning surface ¢) itcan test thicker and highly attenuating materials d) all of the above e) (a) and (b) 16) FOR A 5 MHZ, 15MM DIA. CRYSTAL, WHICH OF THE FOLLWING FOCAL[SIIS/ARE POSSIBLE FOR AN IMMERSION FOCUED PROBE : a) 150mm b) 200 mm ©) 300 mm D) 400mm E) (a) and (b) 17) Which of the following is/are advantage (s) of immersion testing over contact testing. A) Ability to use focused probes b) Ease of automation ¢) Ability to examine very thick sections d) All of the above e) (a) and (b) 18) DAC method for sizing of flaws is used when the size of flaw is ; a) Exactly equal to the sound beam dimension b) Significantly more than the sound beam dimension ¢) Smaller than the sound beam dimension d) Slightly more than the sound beam dimension 19) While plotting a DAC on a steel block using 12 nun dia. normal beam pi-idly If certain frequency, the highest point of DAC observed at a metal path distance of approximately 50 mm. The probe is likely to be of frequency (Viste! = 6000). A)4MHz 8) 2 MHz ©) 8 MHz D) Data in-sufficient 20) Toe-crack on the scanning surface in the weld joint is best detected by: A) Angle beam pulse echo technique 8B) Normal beam technique €) Tandem technique D)all of the above 21) Which of the following wave mode(s) will be present in medium 2 when the incident angle is more than 0 deg. but less than the first critical angle? a) Longitudinal b) Shear ©) Both (a) and d) None of the above 22) At 2nd critical angle, what will be angle of refracted longitudinal wave is steel? a) 45 deg. b) 90 deg. o) 15 deg, d) Refracted longitudinal wave will not exist in steel 23) For an unknown material, the Ast critical angle when water is used as medium |is found to be 100. When ‘medium 1 is changed to perspex, the critical angle will (VL-water = 1500 m/s, VL-perspex = 2730 m/s) a) Increase b) Decrease ¢) Remains same 4) Data in-sufficient 24) in a given material, it was observed that the beam spread angle using some probe is 10 deg. In the same material. if the diameter of crystal is doubled and the frequency is halfed, the beam spread angle will be: a) 10 deg. b) 20 deg, o)Sdeg, 4) 2.5 deg. ) Data insufficient 25) Scattering of sound may result in a) Improvement in signal to noise ratio b) decrease in signal to noise ratio ©) No change in signal to noise ratio d) Better sensitivity and penetration Part-2 Which gal is harmful on ozone lager Test method can distinguish between 316 to 416 Which welding process below 450 Mostly crystalline crystal structure Age hardening another name Structural which non - ferrous metal useful Which casting process given oxygen for quality products 8} Al-boron - alloy is made by ? 9} Ideal sampling plan is ? 10} Powder metallurgy for bending 11} Color contrast deterrent - SNT -TC-la interface 12} Which collimator using in rt long length plate weld joint using in two films to cover 13} Film density efficacity reasons 14} Code contact in lipophilic 15} Halogen contact in PTV which internal mostly effects 16} Flux Density - units- in SI 17}halt Effect master size 18} Prods current calculation ? 19} UG- calculation 20} Time -distance ~ calculation 21} Fixing time given development time 22} Which joint given development time 23} Which joint is type cause examined? 24} By rt 25}Socket weld joint which type method applicable 26} The image of rt fade after years 27} Ae limitations 28} In aircraft crack which type method applicable 29} In aircraft electrical conductivity merged high given below which one attached 30} Acceleration frequency range in eddy current 31} Which you are harmful on ozone layer 32} Given fillet weld log lengths same using fillet gauge what will be measured 33} Profile ecometor used for ? 34} Ae sensor ax opiated? 35} Radio sotope in NR?

You might also like