3"(OD 88MM)
4MM THICKNESS SYSTEM
8. LAP SLPICE SHALL BE MINIMUM 60 TIMES DIAMETER OF
BAR
9. AGGREGATE SHALL BE WELL GRADED AND MAXIMUM
SIZE OF COARSE AGGREGATE SHALL BE 19mm
CONFORMING TO ASTM C-33.
10. COARSE SAND SHALL BE FREE FROM SILT AND DUST.
11. CONCRETE SHALL BE MIXED BY MECHANICAL MEANS.
12. CONCRETE SHALL BE VIBRATED WITH A VIBRATOR OF
7000 RPM MAXIMUM.
TYPICAL STREET LIGHT
13. POTABLE WATER SHALL BE USED FOR ALL CONCRETING
(180 WATT MIN.)
AND CURING.
14. CURING MUST BE CONTINUED FOR AT LEAST 10 DAYS.
4"(OD 114MM) 15. PURE COPPER CABLES OF SPECIFICATION EQUIVALENT
500 TO NEWAGE/PAKISTAN CABLES SHALL BE USED.
4MM THICKNESS
16. ALL THE WIRING SHALL BE DONE IN PVC/SS CONDUITS
2000
AT SUITABLE LOCATION.
50 18. THE NUMBERS & TYPE OF LIGHTING UNIT (FLOOD
LIGHTS/STREET LIGHTS) SHALL BE AS PER APPROVAL
PEDESTAL SECTION
OF ENGINEER IN-CHARGE.
19. ALL THE CABLE SIZES AND NETWORK SHALL BE AS PER
APPROVAL OF ENGINEER IN CHARGE.
20. MAIN ELECTRICITY SUPPLY TO DISTRIBUTION BOARD
400
SHALL BE PROVIDED BY RESPECTIVE GRID STATION
IN-CHARGE.
300
50 21. ALL THE LIGHTING POLE SHOULD BE PROPERLY
EARTHED/GROUNDED.
50
100
BOTH WAYS
SPECIFIC PURPOSE/ SITUATION/ LOCATION FOR WHICH
IT HAS BEEN APPROVED/ ISSUED.
R.C.C 1:1.5:3
300
400
16
(SRC)
900
260
STIFFENER PLATE
DRAWN SIKANDAR
400
300
CHECKED ---
TUBULAR LIGHTING POLE
100
ASSTT.
MANAGER
MARYAM
MANSHA
DESIGN (8.0 METERS)
50