Professional Documents
Culture Documents
(F9111)
45, Rue de Villiers
92526 NEUILLY Sur SEINE CEDEX-FRANCE
Tel: (33) 1 57 77 80 00
Fax: (33) 1 57 77 80 24
RECORD OF REVISIONS
TASK 63-49-15-870-801-A01
1. Description and Operation
A. Description
(1) Purpose
This pressure transmitter is an inductor type instrument used in conjunction with a ratiometer-
type indicator to provide remote indication of the pressure in a oil system.
(2) Identification - Modification State
(a) The identification plate gives this data:
- Manufacturer’s name.
- Designation of the equipment.
- Customer code.
- Date of manufacture (Date).
- Part Number of the equipment (P/N).
- Serial Number of the equipment (S/N).
- Inspection stamp.
(b) Changes to the equipment are shown as follows:
- For important changes (referred to as "Modifications"), a numeral is added at the end
of the Part Number. This numeral is increased at each subsequent modification to the
equipment.
- For less important changes (referred to as "Amendments"), an upper-case letter is
written on a different label (referred to as the "Amendment Label").
63-49-15-08-0001.cgm
TASK 63-49-15-700-801-A01
1. Testing
A. General
(1) Special Tools, Fixtures and Equipment
(a) In addition to the standard tool kit, special tools will be necessary for some operations.
These tools will be either locally manufactured or supplied by the manufacturer.
(b) The locally-manufactured tools and special tools supplied by the manufacturer are
illustrated and listed in the "SPECIAL TOOLS, FIXTURES, EQUIPMENT AND
CONSUMABLE" section.
(2) Test conditions:
Unless stated differently in some tests, the test of the equipment is done in the following
conditions:
- Temperature: 20 °C +/- 5 °C.
- Test position: Not significant.
(3) Connection: Refer to Figure 2 / 63-49-15-991-101-A01
B. Procedure
(1) Insulation resistance
- With 45 VDC applied, the insulation resistance between the receptacle pins connected
together and the case (ground) should be greater than or equal to 20 Mohms.
(2) Accuracy test
- Switch on the 28 VDC power supply.
- Gradually vary the pressure in increasing then decreasing values so as to set the digital
voltmeter to each of the values given in table.
- At each setting, the difference between the pressure read on the pressure gage and the
corresponding theoretical value should not exceed +/- 200 hPa.
Table 1 / 63-49-15-992-101 : Accuracy test
Pressure (hPa) 0 2 4 6 8 10
63-49-15-08-0002.cgm
Schematics and Wiring Diagram
TASK 63-49-15-995-801-A01
1. Schematic and Electrical Diagram
A. Electrical Diagram
Refer to Figure 3 / 63-49-15-991-201-A01
Figure 3 / 63-49-15-991-201-1
Electrical Diagram
63-49-15-08-0003.cgm
TASK 63-49-15-100-801-A01
1. Cleaning
A. General
(1) Material Required: Refer to Table 4 / 63-49-15-992-903-A01
B. Procedure
(1) Metal parts
(a) Remove dust and traces of grease with H-type gasoline and lint-free cloth.
(2) Connector
(a) Clean the connector by means of a low-pressure airjet.
Check
TASK 63-49-15-200-801-A01
1. Check
A. General
(1) Equipment
(a) Not applicable
B. Procedure
(1) Metal parts
(a) Make sure that the parts are clean and show no signs of deformation, cracks, scratches,
corrosion...
(2) Connector
(a) Check the pins of connector.
Repair
TASK 63-49-15-300-801-A01
1. Repair
All operations not described in this document must be carried out by the manufacturer, on his premises
and according to the approved industrial file.
TASK 63-49-15-940-801-A01
1. Special Tools, Fixture, Equipment and Consumable
A. Tools, Fixture and Equipment
- Not applicable
B. Standard Tools, Fixtures and Equipment
NOTE: You can use alternative equipment from other suppliers if they have equivalent properties.
Table 2 / 63-49-15-992-901 : Standard Tools
1 3 4 5 6 7 8
NOTE: The meanings of the numbers in the USE column are as follows:
1: TESTING 3: DISASSEMBLY 4: CLEANING 5: CHECK 6: REPAIR 7: ASSEMBLY
8: STORAGE
C. Specific Tools
NOTE: You can use alternative equipment from other suppliers if they have equivalent properties.
Table 3 / 63-49-15-992-902 : Specific Tools
TASK 63-49-15-940-803-A01
2. Consumable
NOTE: Equivalent substitutes can be used. A non-exhaustive list of substitutes can be found in the
STANDARD PRACTICES MANUAL ATA No 20-00-02.
NOTE: The meaning of the numbers in the USE column are as follows:
1: TESTING 3: DISASSEMBLY 4: CLEANING 5: CHECK 6: REPAIR 15: ASSEMBLY
8: STORAGE
TASK 63-49-15-500-801-A01
1. Storage and Transportation
A. General
(1) The storage conditions are as follows:
- Storage temperature: - 55 °C to + 90 °C.
- Relative humidity: 70% max.
(2) Consumable: Refer to Table 4 / 63-49-15-992-903-A01
B. Procedure
(1) Put the protective plug on the connector.
(2) Put the equipment with a desiccant product in a polyethylene bag and then in the cardboard box.