To share about the overheat and wave in the expansion tank.

Failure/Problem
Damaged thermostat.

Symptom

The water wave in the expansion tank and overheat.

History

Nothing special case.

Cause & analysis

The thermostat can’t open and so the water can’t circulate. So, it is overheat and wave in the expansion
tank.

Action

Change the thermostat and test run the m/c , it is Ok.

Parts
Part number responsible Part number replaced
Parts no. Description Qty Parts no. Description Qty
VOE20450736 Thermostat 1 VOE20450736 Thermostat 1

Picture

Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.
Win Progress Co., Ltd. TSB-MTL-VCE-2013-Jan-
001
TECHNICAL SERVICE BULLETIN
Manufacturer Product Line Engine Model Page
VOLVO Excavator D7EEAE2
Component Group Model Series Date
EC290BLC 18058 28.1.2013

Remark

Prepared by: Wai Phyo Tun Title: Apprentice Mechanic


Acknowledged by Title: Chief Engineer
Company :Win Progress(Meiktila branch)

Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.