Professional Documents
Culture Documents
SCS38
SCS38
Main Bearing
Gas Chamber
Bladder Accumulator
Outer Body
Pressure Chamber
Metering Orifices
Issue 4.2003 Specifications subject to change
120 15 15
B Stroke
Hub B Hub
Stroke
160 Amax Amax
32 32
∅ 18
60
60 36 15
Stroke
Hub
15
160 D Emax
190 Amax
Technical Data
Impact velocity range v: 0.9 to 4.6 m/s. In Creep Speed: The shock absorber can be pushed
Reaction force Q: at max. capacity rating = 80 kN max. through its stroke.
Energy capacity W3: At max. side load angle do not In creep speed conditions the shock absorber provides
exceed 80 % of rated max. energy capacity below. minimal resistance and there is no braking effect.
Return force: 0.6 to 0.7 kN. Calculation: For further details of calculation and selection
please consult ACE.
Filling pressure: approx. 2 bar.
The calculation and selection of the correct ACE Stacker
Operating temperature range: -12°C to 66°C Crane Shock Absorber for your application should be
(For lower temperatures please consult ACE). referred to ACE for approval and assignment of unique
Issue 4.2003 Specifications subject to change
identification number.
HYDNET ab: Stockholm tel:08-59 470 470 fax:08-59 470 479, Göteborg tel:031-499 490 fax:031-499 499 Malmö tel:040-66 44 511 fax:040-66 43 510 61