21'-7 1/4" 13'-2 1/4" FOUNDATION NOTES

390 E CORPORATE DRIVE STE 112


1. ASSUMED SOIL BEARING PRESSURE OF 1500 P.S.F.
2. ALL CONC. TO BEAR ON FIRM, NATURAL, UNDISTURBED SOIL.

MERIDIAN, ID 83642
9 (TYP.) 3. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS TO BE:

2'-0"

#208-283-3775
WALLS NOT EXPOSED TO WEATHER 2500 PSI
WALLS EXPOSED TO WEATHER 3000PSI
8 (TYP.) PORCHES, STEPS & GARAGE SLAB 3500PSI
4. EXTEND FOOTING BELOW FROST LINE, (24" MIN. INTO NATURAL
94'-10" SOIL FOR 1 STORY AND 2 STORY CONSTRUCTION

8'-6"

4'-6"
5. THE GRADE AWAY FROM THE FOUNDATION WALLS TOF ALL A MIN.
6'-0" 15'-0" 20'-11" 13'-5" 18'-0" 5'-6" 16'-0" 6' WITHIN THE FIRST 10 FEET.
SIMPSON JOIST HANGER 6. 1/2" DIA. X 10" ANCHOR BOLTS TO BE USED @ 6'-0" O.C. & 7" MIN.
OR EQUAL (TYP.) INTO CONC. & 12" MAX FROM ANY CORNER W/ 2" DIA. WASHERS
START JOIST 4 & 1/2" DIA. NUTS (CONC. STEM WALLS).
16"x6" FOUNDATION 7. 18" MIN. CRAWL SPACE W 6MIL. BLACK W/6 MIL. BLACK VAPOR BARRIER
LAYOUT HERE (TYP.) THROUGHOUT LAP JOINTS 12" MIN. EXTEND UP STEM WALL & STAPLE TO
MUD SILL.
8. SUGGESTED REBAR PLACEMENT TO BE: 2- #4 HORIZONTAL REBAR

5'-6"
IN FOOTING AND VERTICAL REBAR @ 6'-0" O.C. IN ALL 2' EXTERIOR
3 CONCRETE STEM WALLS. ACTUAL REBAR INSTALLATION TO FOLLOW
VENT WELL (TYP.) LOCAL REQUIREMENTS.

9'-6"
9. SUGGESTED REBAR PLACEMENT TO BE: 2- #4 HORIZONTAL REBAR

7'-0"
IN FOOTING AND 2-#4 HORIZONTAL REBAR IN STEM WALL EQUALLY SPACED

12'-0"
AND VERTICAL REBAR @ 6'-0" O.C. IN ALL 2' EXTERIOR CONCRETE STEM

10'-0"
WALLS. ACTUAL REBAR INSTALLATION TO FOLLOW LOCAL REQUIREMENTS.

3'-6"
4" REBAR@ 2'-0"o.c. (TYP.) 10. BASEMENT CONCRETE WALLS TO FOLLOW LOCAL REQUIREMENTS AND
OR PER APPROVED STRUCTURAL ENGINEERING DRAWINGS.

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
11. ALL CONCRETE PORCHES TO BE DOWELED TO EXTERIOR STEM WALL

FIE
14'-0"

WITH #4 REBAR @ 2'-0" O.C.


12. CONTRACTOR TO VERIFY ALL MEASUREMENTS AND SQUARENESS OF
CORNERS PRIOR TO POURING AND AFTER COMPLETION OF FINAL WORK.
ALL FINISHED WORK (TOP OF STEM WALLS, TOP OF FOOTINGS, SLABS,
PORCHES) TO BE FINISHED AS LEVEL AS POSSIBLE.
1 1 1 1 13. ADD SIMPSON HPAHD22 TIE DOWN STRAP TO ALL GARAGE WING WALLS
AND ANY FOUNDATION WALL LESS THAN 2' LONG, IF REQUIRED PER LOCAL
16"o.c. BLOCKING

These Drawings contain confidential proprietary information and are the property
2X4 PONY WALL OVER BUILDING DEPARTMENT.
CONTINUOUS ALONG 16"X8" CONCRETE
LENGTH OF BRACED WALL FOOTING (TYP.)
PANEL AS REQ'D.

SHEET NOTES

9'-0"
9'-0"

11 1 BLOCK OUT PONY WALL FOR 18"x24" CRAWL

18'-0"

WALKER RESIDENCE
2'-0" ACCESS
3 (TYP.)
2 CONTINUOUS FOUNDATION WALL BLOCK OUT
AS REQUIRED.
1 1 1 1 1
3 CRAWL SPACE ACCESS.
40'-6"

3/4" FLOOR SHEATHING OVER 9 1/2" TJI FLOOR

FOUNDATION PLAN
JOIST@24"o.c. GLUE AND NAIL SHEATHING 4 4" CONCRETE SLAB ON 4" COMPACT GRAVEL
(TYP.) BASE W/ 6" THICKENED SLAB EDGE TO
1'-0" 1'-10" 1'-0" 2'-0" FROSTLINE W/ 4" x 18" BAR @ 24" O.C.
7

7'-0"
(TYP.) 2'-0" 1'-0" 2'-0" WH
18'-6"

12'-5" 3'-1" 6"


9'-6 1/2"

5 ALL FOUNDATIONS, FOOTINGS, AND


BALCONY/ROOF SUPPORT PIERS TO MAINTAIN
A MINIMUM DEPTH OF 24" BELOW FINISH GRADE
ELEVATION FOR FROST PROTECTION.

1'-3"
6 ANCHOR BOLTS PER R403.1.6 AS REQUIRED

1'-3"
is iii
PER PORTAL FRAMING AT GARAGE DOORS

3'-8 1/4"
6" x 24" CONC. STEM WALL OVER 2
16" x 8" CONC. FOOTING (TYP.) 7 CONC. STOOP.
1 1 1

I
8 SIMPSON POST BASE OR EQUAL.

-
7'-9"
9 24"Ø x 24" MIN. DEEP CONC. SUPPORT
2'-6" 5'-11 1/4" 3'-9 1/2" 28'-9 1/4" PIER@CONC. SLAB.
16" x 8" CONC. FOOTING (TYP.)
REVISIONS
2'-0"

2'-0"
T

12/28/2023
11'-11 1/2"

DATE
5
2'-11" 14'-0 1/2" 13'-0"
8'-0"

5'-7 1/4"

BEAM
6'-0"

adhote
4
GARAGE FLOOR
4" CONC. SLAB OVER 4" COMPACTED GRANULAR & FILL.
36''x36''x10'' CONC. FOOTING

28'-6"
APPROVED POST CAP
PROVIDE 1/2" FIBERBOARD EXPANSION JOINTS & SLAB

7
PERMITER AND CONTROL JOINTS AT 10" O.C. BOTH
2'-4 3/4"
2'-0"

DIRECTIONS. SLOPE 2" TO O.H. DOORS

29'-3"
6x6 POST

1'-11" 12'-4"

SLOPE
8'-0" 15'-4 1/2" 29'-11 1/2"

22'-0"

E
53'-4"

HideLargepost
6 2 6
SIMPSON POST BAST OR
EQUAL
6 2 6

2'-6"
24" Ø x 24" CONCRETE

ISSUE FOR CONSTRUCTION


FOOTING

2'-0"
3'-5" 18'-2" 3'-5" 3'-0" 10'-2" 3'-4"
25'-0" 16'-6"
41'-6"

DESCRIPTION
2'-0"

site
FOUNDATION PLAN POST DETAIL
1 2

In Folder
1/4" = 1'-0" 1/2" = 1'-0"

NO.
0
Add
SHEET TITLE
FOUNDATION

plan Walthracing
PLAN

All
GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A2.0 0
390 E CORPORATE DRIVE STE 112
FLOOR PLAN NOTES

MERIDIAN, ID 83642
1. ALL STRUCTURAL LUMBER SIDED FOR #2 OR BETTER

#208-283-3775
DOUG FIR LARCH.
2. 2x EXTERIOR STUD FRAMING @ 16' O.C. W/ SINGLE BOTTOM
PLATE AND DOUBLE TOP PLATE.
94'-10" 3. 4x8 HEADERS IN ALL BEARING WALL OPENING UNLESS
OTHERWISE NOTED.
6'-0" 15'-0" 20'-11" 13'-5" 18'-0" 5'-6" 16'-0" 4. ALLOW FOR A 22' x 30' (MIN) ATTIC AND CRAWL SPACE
ACCESS.
6x6 P.T. POST (TYP.)

l
5. ALL METAL CONNECTIONS TO BE SIMPSON CO. OR BETTER
6. 5/8" TYPE 'X' GYP BOARD @ ALL GARAGE COMMON

l l l l
WALLS AND CEILINGS APPLIED TO GARAGE SIDE AND
ALL WALLS, BEAMS, POSTS AND OTHER STRUCTURAL
MEMBERS SUPPORTING FIRE PROTECTED HORIZONTAL
STRUCTURAL MEMBERS.
(2)1 3/4"x11 7/8" 7. DOORS BETWEEN GARAGE AND DWELLING ARE TO BE SELF
CLOSING AND TIGHT FITTING SOLID WOOD DOOR 1 3/8" THICK
OR A DOOR W/ A FIRE PROTECTION RATING OF NOT LESS

8'-6"

4'-6"
(2)1 3/4"x11 7/8"
THAN 20 MINUTES.

(2)1 3/4"x11 7/8"


8. 1/2" GYPSUM BOARD TO BE INSTALLED ON INSIDE WALLS OF

12'-0"
HOUSE.
5'-10 3/4" 3'-4" 5'-9 1/4" COVERED PATIO A4.1 30/60 SH 30/60 SH 9. ALL WINDOWS TO HAVE BREATHER TUBES INSTALLED.
VAULTED CEILING 10. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED
W.I.C.

15'-6"
1 ROOF TRUSSES UNLESS OTHERWISE NOTED.
30/60 SH 30/60 SH 11. ALL CONSTRUCTION PRACTICES USED IN THE CONSTRUCTION

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
26

5'-5 1/2"

used for construction or any other purpose without prior written permission from Risen Home Design.
OF THIS DWELLING SHALL BE DONE IN ACCORDANCE W/ THE

5'-6"

5'-0"
(2) 2x10 (2) 2x10 2018 WHERE APPLICABLE.
2'-6"

R&S
11'-9 1/2" 2 1 12. VENT RANGE HOOD, FANS, AND DRYER TO OUTSIDE AIR.
30/20 PW

CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS


(2) 2x8

9'-6"
30 BEDROOM#3 R&S PRIOR TO COMMENCING WORK.
30/60 SH 30/60 SH

7'-0"

7'-0"
10' CEILING 13. ALL RESCUE WINDOWS FROM SLEEPING AREAS MUST MEET

11'-8"
EQ EQ THE FOLLING REQUIREMENTS:
MASTER (2) 2x10 (2) 2x10 5'-0" 1. SHALL HAVE A NET CLEAR OPENING OF 5.1 SQ. FT.
5'-5 1/2" 5'-0" 5'-0" 5'-5 1/2"

26/60 SH
BEDROOM

These Drawings contain confidential proprietary information and are the property
2. MINIMUM HEIGHT OF 24".

3'-6"
10' CEILING 3. MINIMUM WIDTH OF 20".

5'-11"
30/60 SH 30/60 SH 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44".
14'-0"
9'-7 1/2"

14'-2"

14. EXTERIOR DIMENSIONS ARE TO FACE OF STUD WALL. INTERIOR


DIMENSIONS ARE TO FACE OF STUD WALL.

9'-7 1/2"
14'-1" 60/80 BATH#3 15. ALL FURNACE SWITCHES, PILOTS, AND BURNERS TO BE MINIMUM

9'-5"
DINING 10' CEILING R&S 18" ABOVE FINISHED FLOOR.

BUILT-IN
5'-3 1/2"
10' CEILING
30

5'-11 1/2"
W.I.C.

WALKER RESIDENCE
R&S
IFF
5'-2 1/2"

3'-9 1/2"
7'-4"

3'-6"
2'-0"
30/20 PW

28
(2) 2x8

VAULT LINE
1'-10 1/2"

26

Fireplace
30 5S 7'-3" 5'-8"
GREAT ROOM
1'-0"

5'-0"

26
1 2 VAULTED CEILING 30

18'-5 1/2"
6'-9 1/4" 3'-6" 6'-7 1/4" 3'-8" 2'-3 1/2" 17'-0" 3'-1" 3'-6" 3'-6" 5'-11" 6'-7" 3'-6" 12'-11"

5'-11 1/2"

1st FLOOR PLAN


18'-0"
24 24

7'-10 1/2"
R&S
5'-9"

4'-3 1/2"
5'-7"

8'-0"
W.I.C.
5'-0"

W.I.C.

5S
26

DW

STAIRS UP
A4.1 2 BEDROOM#4 DOOR/WINDOW TAG EXAMPLE
7'-4"

R&S R&S PANTRY 10' CEILING

12'-0 1/2"
12'-9 1/2"

50/40 SL
BUILT-IN

(2) 2x10
40'-6"

DOOR TAG WINDOW TAG


3'-9 1/2" 5S
8'-2"
4'-0"

MASTER 5'-8" 26 = 2'-6" 40/56 SH = 4'-0" x 5'-6" SINGLE HUNG


KITCHEN
6'-3 1/2"

Rangetop

6'-1"
3'-0'' OPENING
6'-0"

BATHROOM 10' CEILING WH


18'-6"

5'-7 1/2"
4'-2 1/2"

FURN

4'-11"

4'-0"
30/60 SH

10' CEILING STORAGE


3'-4"

12'-2"

-
8'-2" 3'-5" 5'-3 1/2" 5'-9" 10'-4" 4'-2" 15'-0 1/2" BELOW
4"

(2) 2x10

1'-3 1/2"

56'-0"
24
20 7'-0'' OPENING 3'-10 1/2" Refrigerator 50
REVISIONS

1'-3"
28
ENTRY

R&S
3'-7"
28 24

12/12/2023
12/19/2023
12/20/2023
12/28/2023
3'-7"

3'-0"

3'-7"

10' CEILING 3'-0'' OPENING


2'-6"
8'-9"

DATE
5S 5'-0" BATH#2
7'-0 1/2"

FD
10' CEILING
8'-7"

30
1 30 5'-0" UTILITY

3'-5 1/2"

7'-3 1/2"
7'-0"
7'-9"
24
A7.1
36/80 5S
10' CEILING 3 A4.0 SQ/FT.
(2) 2x10
1st FLOOR 2275 SF
40/20 SL Dryer Washer BONUS ROOM 327 SF
BEDROOM#2
2'-0"

2'-0"

(2) 2x10 12'-0" GARAGE 1227 SF


10'-8 1/2"

2'-11 1/2" 5'-0 1/2" FRONT PORCH 233 SF


11'-2"

EQ EQ 40/40 SL BACK PATIO 465 SF


12'-6 1/2" 2'-10" 2'-11" 10'-4" 3'-8 1/2" 13'-0"
LINE OF BONUS ROOM
8'-0"

ABOVE
6'-5 1/2"

R&S

COVERED 3-CAR GARAGE


10'-0"
6'-0"

PORCH 10' CEILING

28'-6"
(2)1 3/4"x11 7/8"
(2)1 3/4"x11 7/8"

30'-6 1/2"
30/60 SH 30/60 SH
2'-0"

9 1/2"

4'-9" 6'-2" 6'-2" 4'-9"


6'-0 1/4" 3'-4" 6'-0 1/4"

22'-0"
22'-1"
8'-0" 15'-4 1/2" 1'-11" 1'-7" 9'-2" 1'-7" 15'-8 1/2"
2

A4.0
29'-11 1/2"

ISSUE FOR PRELIMINARY REVIEW


ISSUE FOR PRELIMINARY REVIEW
ISSUE FOR PRELIMINARY REVIEW
2
A7.1

ISSUE FOR CONSTRUCTION


1st FLOOR PLAN 100/80 OVERHEAD DR.

DESCRIPTION
1 1/4" = 1'-0"
(2) 1 3/4'' x 11 7/8''

2'-6"
180/80 OVERHEAD DR.

(3) 1 3/4'' x 11 7/8''

NO.
3'-6" 18'-0" 3'-6" 3'-1" 10'-0" 3'-5"

C
A
B

0
SHEET NOTES 25'-0" 16'-6"

1 CRAWL SPACE ACCESS. COORDINATE WITH JOIST LAYOUT.


41'-6"
SHEET TITLE
1st FLOOR
2 ATTIC SPACE ACCESS. COORDINATE WITH TRUSS LAYOUT.
PLAN

GENERAL CONDITIONS
TABLE R402.1.1 DRAWINGS & SPECIFICATIONS
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT RHD PROJECT NUMBER: RHD-1027
SEE 2018 IRC IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: MM DATE:12/12/2023
CLIMATE ZONE FENESTRATION SKYLIGHT GLAZED CEILING WOOD FRAM MASS FLOOR BASEMENT SLAB CRAWLSPACE ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
R302.7 PROVIDE UNDERSTAIR PROTECTION AS REQUIRED CHECKED BY: DATE:12/12/2023
U-FACTOR U-FACTOR FENESTRATION R-VALUE WALL R-VALUE WALL R-VALUE WALL R-VALUE WALL CONDITIONS MAY ARISE DURING DESIGN. AND/OR SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN -
R302.11 PROVIDE FIREBLOCKING AS REQUIRED
SHGC R-VALUE R-VALUE R-VALUE R303.7 PROVIDE SWITCHING AND ILLUMINATION AS REQUIRED CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
NOTE: VERIFY ALL WINDOW/DOOR ROUGH OPENING AND R305 PROVIDE SUFFICIENT CEILING HEIGHTS ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
5 AND
MARINE 4 0.35 0.60 NR 38 20 OR 13+5 h 13/17 30 g 10/13 10, 2 ft 10/13 HEADER HEIGHT AND THE SAME FOR TRIM PACKAGE. VERIFY
STANDARD HEIGHTS WITH CONTRACTOR BEFORE FRAMING.
R311.7 MEET STAIRWAY REQUIREMENTS
R312 MEET GUARD REQUIREMENTS
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A3.0 0
all

390 E CORPORATE DRIVE STE 112


Dim

MERIDIAN, ID 83642
#208-283-3775
74
1-1 2-1 3-1 4-1

an
COVERED PATIO
WSP
A4.1
C-1

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
1

used for construction or any other purpose without prior written permission from Risen Home Design.
WSP WSP

WSP
WSP
CS-WSP W.I.C.

t.FI I

These Drawings contain confidential proprietary information and are the property
BEDROOM#3

i
MASTER WSP
BEDROOM
DINING BATH#3

WALKER RESIDENCE
WSP
GB GB W.I.C.

WSP
Forefext

SHEAR WALL PLAN


GREAT ROOM
WSP

W.I.C. W.I.C. PANTRY

A4.1 2

BEDROOM#4

MASTER KITCHEN
WH
BATHROOM

-
WSP REVISIONS
43
WSP WSP

12/28/2023
DATE
WSP
B
ENTRY
FD BATH#2
UTILITY
WSP

3 A4.0

BEDROOM#2 CS-WSP

ABW
WSP WSP

WSP
WSP

COVERED PORCH
WSP

3-CAR GARAGE

B-1 WSP WSP

A4.0

ISSUE FOR CONSTRUCTION


WSP

DESCRIPTION
A-1
WSP

PFG PFG

NO.
0
PFG PFG

SHEET TITLE

shearwalt
SHEAR WALL
PLAN

BRACING DETAILS DRAWINGS & SPECIFICATIONS


GENERAL CONDITIONS
RHD PROJECT NUMBER: RHD-1027
METHOD MATERIAL CONNECTION CRITERIA IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
WSP WOOD STRUCTURAL PANEL (SEE SECTION R604) EXTERIOR SHEATHING: SEE IRC TABLE NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
R6023(3) INTERIOR SHEATHING: SEE IRC ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
TABLE R6023(1) CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
PFH INTERMITTENT PORTAL FRAME SEE SECTION R602.10.3.3 CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
ABW ALTERNATE BRACED WALL SEE SECTION R602.10.3.2
GB GYPSUM BOARD SEE SECTION R702.3.5
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A3.1 0
R806 - PROVIDE ADEQUATE ATTIC VENTILATION.

390 E CORPORATE DRIVE STE 112


MERIDIAN, ID 83642
#208-283-3775
12
10

12
12 10
10

(APPROX. HEIGHT)
23'-10 3/4"

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
These Drawings contain confidential proprietary information and are the property
WALKER RESIDENCE
FRONT VIEW
2 1/4" = 1'-0"

ELEVATIONS
-
STAIRS DN.

REVISIONS

12/12/2023
12/19/2023
12/20/2023
12/28/2023
DATE
2'-7" 3'-6" 5'-11"
2'-4 1/2"

CLOSET

24

BONUS ROOM 12
6
12
6
27'-2 1/2"

27'-2 1/2"

12'-0"

ISSUE FOR PRELIMINARY REVIEW


ISSUE FOR PRELIMINARY REVIEW
ISSUE FOR PRELIMINARY REVIEW
ISSUE FOR CONSTRUCTION
DESCRIPTION
NO.

C
A
B

0
30/50 SH 30/50 SH
4'-4" 3'-4" 4'-4"
RIGHT VIEW
12'-0" 3 1/4" = 1'-0"
SHEET TITLE
ELEVATIONS
BONUS ROOM
1 1/4" = 1'-0"

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: MM DATE:12/12/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: - DATE:12/12/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A4.0 0
390 E CORPORATE DRIVE STE 112
MERIDIAN, ID 83642
#208-283-3775
12 12
10 10

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
These Drawings contain confidential proprietary information and are the property
BACK VIEW
1

WALKER RESIDENCE
1/4" = 1'-0"

12
6

ELEVATIONS
12

-
6

REVISIONS

12/19/2023
12/20/2023
12/28/2023
DATE
LEFT VIEW
2 1/4" = 1'-0"

ISSUE FOR PRELIMINARY REVIEW


ISSUE FOR PRELIMINARY REVIEW
ISSUE FOR CONSTRUCTION
DESCRIPTION
NO.
A
B
0
SHEET TITLE
ELEVATIONS

3D VIEW
3 GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: MM DATE:12/19/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: - DATE:12/19/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A4.1 0
ROOF NOTES

390 E CORPORATE DRIVE STE 112


1. TRUSS LAYOUT AND DESIGN TO BE SPECIFIED BY LOCAL TRUSS COMPANY. BUILDING
CONTRACTOR TO VERIFY ALL TRUSS LAYOUTS WITH TRUSS COMPANY BEFORE
ORDERING. ALL TRUSS PROBLEMS TO BE ADDRESSED BY CONTRACTOR AND TRUSS
COMPANY.

MERIDIAN, ID 83642
2. ALL ROOF AND SOFFIT VENTS TO BE INSTALLED ACCORDING TO U.B.C. AND

#208-283-3775
APPLICABLE LOCAL CODES.
3. ALL TOTAL SPANS MAY VARY DEPENDING ON GIRDER TRUSS PLACEMENT. (IF
NEEDED)
21'-10" 4. ALL WINDOW HEADERS, GARAGE DOOR HEADER AND MICRO-LAM BEAMS UNDER
ROOF LOAD TO BE SPECIFIED BY LOCAL TRUSS COMPANY.
5. TRUSS COMPANY TO CONFIRM DESIGN ROOF SNOW LOAD SHOWN WITH COUNTY
REQUIREMENTS OF THIS HOUSE LOCATION.

DESIGN CRITERIA
CALDWELL
LOCATION: (CITY)_______________ (COUNTY)______________
CANYON
18'-0"

e
• 30PSF
DESIGN ROOF SNOW LOAD: ______________
• 115MPH
DESIGN WIND SPEED:___________
• --
DESIGN WIND EXPOSURE TYPE:____________
• DESIGN EARTH QUAKE ZONE:______________
D1
• 24"
FROST DEPTH:____________
10:12 10:12

3:12

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
Middleton

used for construction or any other purpose without prior written permission from Risen Home Design.
10:12
10:12

6:12

These Drawings contain confidential proprietary information and are the property
6:12

WALKER RESIDENCE
6:12
10:12

lane

6:12
32'-6"

6:12

ROOF PLAN
0

6:12
18'-6"

-
REVISIONS

12/28/2023
6:12

DATE
6:12
10:12
10:12

10:12 10:12

3:12

28'-6"
15'-4 1/2"

597 10:12 10:12

6:12
12'-3 1/2"

frIii

ISSUE FOR CONSTRUCTION


E

DESCRIPTION
oI62

NO.
89

0
25'-0"

1
ROOF PLAN SHEET TITLE
1/4" = 1'-0"
ROOF PLAN

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A5.0 0
ELECTRICAL LEGEND

390 E CORPORATE DRIVE STE 112


SINGLE POLE SWITCH DB DOOR BELL BUTTON

3-WAY SWITCH CHIME DOOR BELL CHIME

MERIDIAN, ID 83642
3

#208-283-3775
4-WAY SWITCH GD GARAGE DOOR
4 BUTTON

DIMMER SWITCH GDO GARAGE DOOR


D OPENER

220 VOLT OUTLET WEATHERPROOF


220 WPGFI OUTLET

DUPLEX OUTLET CEILING OUTLET


CLG

GROUND FAULT FLOOR OUTLET


GFI OUTLET FLR
CARBON MONOXIDE
S SMOKE DETECTOR CS & SMOKE DETECTOR
COMBO
CARBON MONOXIDE
C NETWORK OUTLET
DETECTOR DATA

TV TELEVISION OUTLET TELEPHONE OUTLET


PH

PANEL SERVICE PANEL GARBAGE DISPOSAL

SERVICE METER ACCENT LIGHT


M ACCENT

WALL MOUNT LIGHT SINGLE SCONCE

FLOOD LIGHT DOUBLE SCONCE

3
FLOOD

GFI 3 BULB STRIP LIGHT


STR
STAIR LIGHT

GFI BATH FAN & LIGHT


COMBO
BATH FAN

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
CASTER CLOSET CASTER LIGHT UC UNDER CABINET
S LIGHT

3 PC PULL CHAIN LIGHT K KEYLESS LIGHT

FLUSH MOUNT LIGHT HANGING LIGHT


HANGING

HANGING PENDANT MINI MINIATURE PUCK


PNDT
LIGHT LIGHT

RECESSED CAN LIGHT RECESSED EYEBALL


EB LIGHT
FLUORESCENT LIGHT FLUORESCENT LIGHT

These Drawings contain confidential proprietary information and are the property
CS GFI RECTANGULAR
FR
ROUND
3 3

3
S
CF
S
CEILING FAN LIGHT w/ FAN
ROUGH

3
LCF LCF

WALKER RESIDENCE
ROUGH

FLOOR ELECTRICAL PLAN


GFI LIGHTED CEILING LIGHT & FAN
FAN ROUGH

GFI GFI

220V GFI
WH
220V

I
3
CS

GFI CS 3
GFI GFI

3
FD
GFI

-
4 REVISIONS
220V GFI
GFI GFI

12/28/2023
DATE
I GFI

3
CS

GFI

GFI

GFI

ISSUE FOR CONSTRUCTION


1ST FLOOR ELECTRICAL PLAN
1

DESCRIPTION
1/4" = 1'-0"

NO.
0
SHEET TITLE
BONUS ROOM ELECTRICAL PLAN ELECTRICAL
2 1/4" = 1'-0"
PLAN

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A6.0 0
390 E CORPORATE DRIVE STE 112
FASTEN BRCING
7/16" OSB SHEATHING ≤10FT. FROM EDGE OF MATERIAL AS REQUIRED
BRACED WALL TO START BY TABLE R602.3(3)

MERIDIAN, ID 83642
OF WALL BRACE ≤20 FT. BETWEEN CLOSET

#208-283-3775
30 YR. COMP. ROOFING EDGES OF WALL BRACES
OVER #15 BLDG. FELT

TRUSS DESIGN & ENGINEERING


BY TRUSS COMPANY

R-38 CEILING INSULATION

1'-4"

3 1/2" x 9" GLU-LAM Fb 1700


1/2" SHEETROCK BLOCK PANEL EDGES TO
1" x 6" FASICA INSULATE VOID SPACE MAINTAIN FASTENER SPACING
+ 9'-1 1/8" A.F.F.
2 x 6 WOOD FILLER

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
BOXED SOFFET WITH
REQUIRED VENTING

TYPICAL HEADER @ DOOR & WINDOWS

These Drawings contain confidential proprietary information and are the property
NOTES:

1 X= 6" OR 8" MIN. AS REQUIRED PER LOCAL BUILDING CODE.

2 SUGGESTED REBAR PLACEMENT TO BE: 2 - #4 REBAR IN FOOTING AND STUDS


1'-4" o.c.
VERTICAL #4 REBAR @ 4' O.C. IN ALL 2' EXTERIOR CONCRETE STEM WALLS.
(TYP.)
REFERENCE FOUNDATION PLAN A3.0 FOR COUNTY REQUIREMENTS AND NOTES.

WALKER RESIDENCE
3 SPECIAL REBAR PLACEMENT TO BE: 2-#4 REBAR IN FOOTING AND 2-#4 HORZ. REBAR IN
STEM WALL EQUALLY SPACED AND VERTICAL #4 REBAR@ 4'o.c. IN ALL 2' EXTERIOR
CONCRETE STEM WALLS. REFERENCE FOUNDATION PLAN A3.0 FOR COUNTY
REQUIREMENTS AND NOTES.
WSP DETAIL
2 3/4" = 1'-0"
2 x 6 STUDS @ 16" o.c.
R-21 EXT. WALL INSULATION
SIDING AS NOTED ON ELEVATIONS (TYP.)
1/2" SHEETROCK
7/16 WAFERBOARD SHEATHING

DETAILS
3/4" OSB T& G FLOOR EXTENT OF HEADER
P.T. 2 X 6 FIR MUD-SILL GLUE & NAIL TO FLOOR JOISTS
SINGLE PORTAL FRAME(ONE BRACED WALL PANEL)
SIMPSON OR EQUAL JOIST HANGER (TYP.)
1/2"x 10" LG. CONCRETE
BOLTS @ 6'-0" O.C. EXTENT OF HEADER
SINGLE PORTAL FRAME(ONE BRACED WALL PANEL)
X"min. 1

-
2% Grade 9 1/2" TJI-150 @ 24" o.c. 11-1/4" DEEP HEADER (MIN)

R-30 INSULATION @ FLOOR JOISTS (TYP)


REVISIONS
2'-0"

12/28/2023
6" THICK STEM WALL PER PLAN 1000lb STRAP

DATE
TYPICAL PORTAL FRAME
SPECIAL REBAR PLACEMENT & REQUIEMENTS SEE NOTE 3 2 x 4 PONY WALL STACKED ON 1000lb STRAP OPPOSITE SHEATHING CONSTRUCTION
8" CONT. CONC. FOOTING.
(Stack 2x4 cripple under each Joist)
STANDARD REBAR PLACEMENT & REQUIREMENTS
2
SEE NOTE 2
8"

8"
.006 VISQUEEN GROUND COVER

MAX. HEIGHT
MIN. 2x4 FRAMING 5
MIN. DOUBLE

10'-0"
2x4 POST
3
1'-4" 1'-4"

WALL SECTION
1 1" = 1'-0" 3/8" MIN. THICKNESS
WOOD STRUCTURAL
PANEL SHEATHING

4
MIN. 1000lb TIE-DOWN
DEVICE

1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" SEE SECTION R602.10.3.3

2'-0"
DOUBLE TOP

HEADROOM
PLATE

6'-8" Min.
LOAD BEARING HEADER

ISSUE FOR CONSTRUCTION


FRONT ELEVATION
NON-LOAD BEARING HEADER 1 FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16d SINKER. NAILS@3in. o.c. (TYP.)

2 FASTEN SHEATHING TO HEADER WITH 8d COMMON OR GALVANIED BOX NAILS IN 3in. GRID
PATTERN AS SHOWN AND 3in. o.c. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) (TYP.)

DESCRIPTION
TYPICAL WINDOW 4" Min.
3 MIN. LENGTH = 16in. FOR ONE STORY, MIN. LENGHT = 24in FOR USE IN THE FIRST OF TWO
ROUGH OPENING
STORY STRUCTURES.

4 MIN 4200lb TIE-DOWN (EBEDDED INTO CONCRETE AND NAILED INTO FRAMING).
DOOR
2'-10"

WINDOW SILL
7 3/4" Max.

(ROUGH OPENIGN) 5 FOR A PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL OCCUR OVER AND BE NAILED TO

NO.
FRAMING

0
COMMON BLOCKING AND OCCUR WITHIN MIDDLE 24in. OF WALL HEIGHT. ONE ROW OF 3in. o.c.
NAILING IS REQUIRED IN EACH PANEL EDGE.

10" Min.
SHEET TITLE
CRIPPLE TRIMMER STUD
STUD STAIR DETAIL PORTAL FRAME HOLD-DOWN DETAIL DETAILS
4 1/4" = 1'-0"
5 1/2" = 1'-0"

TYPICAL STUD BOTTOM PLATE

GENERAL CONDITIONS
FRAMING DETAIL DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
3 1/2" = 1'-0" NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A7.0 0
390 E CORPORATE DRIVE STE 112
MERIDIAN, ID 83642
#208-283-3775
of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
P.E. ROOF TRUSSES

QHis.gg qulatn
MIN. R-49 INSULATION

These Drawings contain confidential proprietary information and are the property
MIN. R-21 INSULATION

WALKER RESIDENCE
Hide

CUT SECTION VIEWS


4" CONCRETE
4" COMP. GRAVEL
9 1/2" TJI FLOOR JOIST
MIN. R-30 INSULATION

BUILDING SECTION 1
1 1/4" = 1'-0"

-
REVISIONS

12/28/2023
DATE
P.E. ROOF TRUSSES

MIN. R-38 INSULATION

MIN. R-21 INSULATION

ISSUE FOR CONSTRUCTION


DESCRIPTION
4" CONCRETE
SIMPSON HNGR (TYP.) MIN. R-30 INSULATION 4" COMP. GRAVEL

NO.
0
SHEET TITLE
BUILDING SECTION 2
2 1/4" = 1'-0"
CUT SECTION
VIEWS

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1027
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE:12/28/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE:12/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A7.1 0

You might also like