** Connecting Details TECHNICAL ROOM


C2 Electronics Cabinet (positioner) NOTE: Cable group either 4-1, either 4-2 and 4-3 could be extended with cable group 4-4 not shown.
PDB Positioner
20
Bulkhead EXAM ROOM CEILING 3/4 Monitors suspension
Room 3
Light
BULKHEAD SYSTEM
(Pre-Cabled)
Control TB3
21 Advantx LCA W/Bolus chasing 27083A P S Legend:
S
A 14
Ground Room
Light
27682A PDB On-Off CJ 512/1
Dose Monitor Display A
Switch 27686A S PDU On-Off CJ4 Downscan supply CJ1 27684A P S W = Water Lines
(TSSC) = Signal Cables
15 S 10750A .
TB2 27685A V Downscan in CJ3
VCIM console CJ712 27676A S V = Video Cables
Shield 1 I = Internal Cable
27678A Without Fluoro UPS S
12 2
X-Ray ON RT Bus CJ301
13 3 Downscan out CJ2 27495A V
28259A
With Fluoro UPS
S H = High Voltage Cables
18 Shield 4
5 Live / Fluoro Monitor 34 = Cable Run Numbers
X-Ray Power ON S
Lamp 6 P = Power Cables
Modular PDU/C2 V 27563A VIDEO IN
19 Shield 7 C2 power 3 Phases
from PDB (For US only) 27660A
16 8 24 V G P Elegance power cable TB602 P Monitor Suspen Pwr Strip P = Field Supplied Cables
27661A
G = Ground Wires FS
X-Ray 9
3 Phase 400V and GND (Independent of
Lamp FL2/CB4 2 wires AC
Door G P 27675A P G
17 Switch 27680A power cable CB600 Power Cables)
11198A = MIS Numbers
B C2 power 3 Phases
from C1 (Not for US) P 27582A AC In /
P
Roadmap / Reference Monitor B
BULKHEAD TABLE

27683A S Debug J18 V 27564A VIDEO IN


or = Not included in GTC
100 wires signal table data #1 BJ400 27672A S
27679A S Ge Bus / Arcnet DJ23
100 wires signal table data #2 BJ201 27673A
P or
Door Interlock TB2 25 wires UIF table power data BJ403 27674A P ECG Display Monitor (Optional) = Optional Selectable in GTC
See Connecting
24 wires Motor power AJ200
V 27568A Red Video Reserved
X Ray On Light TB2
Details ** 27669A P
15 wires signal cable AJ300 27670A S V 27569A Green Video Reserved CONTROL BOOTH
27681A G BOLT 100 wires signal cable data AJ 202 27671A V 27570A Blue Video Reserved Dose Monitor Control
Remote Access Modem Line
S 10750A DISPLAY
C Local Phone Walk Plug (DIRECT) 27587A V 27601A Video H Sync C
S 27126A ION CHAMBER A
V 27602A Video V Sync
S 27126B ION CHAMBER B
Fluoro UPS I/F box (Innova 2100-IQ only)
Fluoro UPS (Innova 2100-IQ only) With Fluoro UPS
S 28259A J2 RT-bus C2 cabinet Bolus Wallbox
UPS control With Fluoro UPS DL Infrared ADVANTX LCA W/BOLUS
28257A S S 28257A J3 UPS control P S 27083A
With Fluoro UPS Remote Receiver CHASING
S 28258A J4 PDB control
Ethernet 28262A S With Fluoro UPS 4-4 S 27581A S 27041A INNOVA W/BOLUS CHASING Control Booth Roadmap
S 28260A J1 RT-bus C1 cabinet
With Fluoro UPS
Monitor
EPO/ON/OFF 28256A S G 28261A Bolt
V 27500A VIDEO IN

Hospital AW Monitor #2
C1 Electronics Cabinet (system) P
Main Power Ethernet HUB Accessories Video Peripheral
D With Fluoro UPS
S 28262A Ethernet (Fluoro UPS) Ethernet RJ POS J5 27662A S V 27732A
V D
3 x 380 to 27495A VIDEO IN
Rectifier

By Pass

S
Output

P 27531 Mains HUB (UPS) RJ45 for FE Laptop J8 27505A S


27496A REMOTE CONTROL
480 VAC Modem with DC Bloc KVM
S 27587A Modem phone line J16 Keyboard, VGA, Mouse extender J6 27493A S AW Video Splitter
P 27532 Mains Modem (non UPS) Live Monitor Option 27732A AW Workstation Central Unit
V
DL & Video Splitter 4-2 V P G 27501A VIDEO IN/AC/
DL video live monitor J26 27563A V
Power Distribution V 27687A LCD Red J41 P
AW Power Strip With keyboard and mouse
Box (Wall PDB) DL video Rdp monitor J30 27564A V To 230Vac
V 27688A LCD Green J42 4 OUTLETS
With Fluoro UPS
Fluoro UPS EPO/ON/OFF 28256A S LCD Blue J43
V 27689A DL Infra Red Receiver J15 27581A S V
V 27690A LCD H Synchro J44 Roadmap Monitor Option AW Workstation Monitor #1
E PDB control 28258A S
With Fluoro UPS
V 27691A LCD V Synchro J45
3rd Monitor Option J28.J1A 27501A V P G
E
VGA
4th Monitor Option J32.J1B 27502A V P G 4-3 V P G 27502A VIDEO IN/AC/
V 27685A P
VCR Video KX6 J24
Control Booth Power Strip
System ON/OFF Loop 27682A S P 27533 Mains Video splitter (non UPS)

P 27472A 5 OUTLETS P
P 27458 Mains DL (UPS)
Provided by installator
JEDI POWER 3 Phases P VCR Control J13 27496A S
P 27526 Mains Fan (UPS) 2 P
Provided by installator 27683A S Debug COM6 J40
Main Ground Wire G Video Main KX6 cable J27 27492A V P
27686A UPS Stop (Zephir Board)
DL Keypad J14 27494A S Secured Power
C2 power 3 Phases Provided by installator J10 GEMNET Plug Injector ACIST Injector/ 10906B/ Strip 3 RED OUTLETS P
(For US only) P G G
EXAM ROOM FLOOR LF Angio Illumina Pedestal Injector 10908B
PDU/C2 power 3 Phases RT Bus (Gitane Board) Video Slave KX6 Rdp J31 27500A V
(Not for US) Provided by installator
P G Universal Interface (LF Angio Illumina Pedestal Injector) 10907B S P
PDU 2 Phases
F (for US only) With Fluoro UPS
28260A RTAC F
KVM - R Mouse
Emergency UPS Stop 27561A S
Without Fluoro UPS Same as ECG Acquisition Head
27678A
S H1C RT Bus (Gitane board) J22
S 27493A
Fiber Channel J7 27512A S DL Keyboard
Provided by installator 27679A S Ge Bus / Arcnet J23 S 27567A Data Reserved
Chiller 3 Phase P G
27523A S Detector Chiller Control J17 Detector power CAN Bus J11 27514A S
1 DL Flat Panel
P 27459 Mains RTAC (UPS)
Vascular Table (Omega or Elegance)
V 27687A J41 LCD Red

Door Light S 27693 CAN & RT lines 15 pins J1


P 27660A Elegance power cable
Injector (J2) 10907B S V 27688A J42 LCD Green
System ON 27661A P
10906B/ V 27689A J43 LCD Blue
JEDI S 27662A RJ45 Ethernet
L BUS BAR
10908B
G
X-Ray tube stator cde DJ2 27664A S V 27690A J44 LCD H Synchro
* Connecting Details S 27693 CAN 15 pins J6
G 27468A BUS BAR Innova 3100/4100 27041A P S
G (Not for US) X-Ray tube temp switches DJ3 27665A S w/ Bolus chasing only
V 27691A J45 LCD V Synchro G
3 Phase 400V Jedi 27473A BUS BAR
X-Ray tube Ingrid DJ1 27663A
TB02
Anode I+ S 27672A J600 Table Data #1
AWG6
3x 160A 27589A H
27673A J601 Table Data #2 Control Booth Live Monitor
2347573

AWG6 Cathode I- 27590A


Jedi S 27677A X-Ray Tube Chiller Control DJ4 P
AWG6 RS232 J3 (Generic IF Board)
(Innova 2100-IQ only) 27701 P 27674A J605 Table Pwr Data
V 27492A VIDEO IN
FUSE BOX LVPS 400 Relay command Oil Pump
PDB

P/N 2364241 Power 27675A AC IN / TB1 (1-2)


STRIP UPS 27702
27694 P 27513A DET. POWER MAINS J1
16A
strip box
AWG10 AWG12 VCIM On-Off Console with
2315513

J47 Bulkhead S 27514A DET. PW CAN J2 L BUS BAR


Strip box #3 ( new ) 27470A G
2358531

AWG10 AWG12
Handswitch
STRIP NON UPS L BUS BAR
PDU P/N 2305956-2
28245
P 27722A DET. PW OUT J3 27471A
strip box S 27676A Signals and 24Vdc
AWG10
AWG10
AWG10

27550 27549 27546 27722A

H PDU & BUS BAR Opto-


Bridge 28254A S
LC Gantry
H
C1- G 28261A J3B J2B J4 DL Keypad
C1-CABINET BUS BAR J1A 27586A DETECTOR
Not used Non UPS Output UPS Output Non UPS Output
P 27586A L BUS BAR S 27494A Serial Link with Power
2350103 Detector Supply 27470A G
G 27468 BUS BAR
AWG10

AWG10

AWG10

20A
J4A Downscan supply 27684A P S 27512A Optic fiber L BUS BAR 27471A
w/ bulkhead
G BUS BAR from PDB
J3A Detector AC
power supply
27513A P W 27511A Detector water FE Laptop
Positioner C2 power 3 Phases pipe in flow
(Not for US) Detector water L BUS BAR 27030 G
C2-
C2-CABINET BUS BAR 27468A G 27510A
pipe out flow S 27505A NO BULKHEAD (Free)
27680A 2 Phase PDU
See Connecting Details * 27473A
BUS BAR
P TB02 3 Phase 400V CB1 TUBE
* Connecting Details X-Ray tube water
(For US only) J4B/J2A Strip AC
27472A P G W 27666A
pipe out flow GND 27030 G
BUS BAR
S 27561A Emergency UPS Stop J17 27667A X-Ray tube water ECG Control Unit (Optional)
pipe in flow
G 27681A BUS BAR J9 Strip AC
27582A P H 27589A S 27560A Data Reserved
J TB02
BUS BAR ANODE I+
J
3x 160A 3Ph to C2 27590A CATHODE I- V 27555A Red Video Reserved
AWG6

S V 27556A Green Video Reserved


2347573

AWG6
S 27686A 27664A X-ray tube stator cde J1
Jedi 27686A PDU ON/OFF J20
AWG6
27665A X-ray tube temp status V 27557A Blue Video Reserved
FUSE BOX
P 27522A
Detector Conditioner Power J3B
V 27558A H SYNC Video Reserved
PDB

P/N 2364241
27663A X-Ray tube ingrid

V 27559A V SYNC Video Reserved


16A
P 27669A J100 Power
AWG10 AWG12 motor
2315513
2358531

AWG10 AWG12
Detector Conditioner S 27670A J206 Collimator
PDB

PDU P/N 2305956 - 2


WATER INLET 27510A W 27671A J205 Data LC
P 27522A Chiller AC power 3 wires
AWG10

AWG10

3 WATER OUTLET 27511A S 27126A ION CHAMBER A CAUTION: For proper operation and regulatory compliance, it is mandatory to follow the guidelines
C1 - CABINET S 27523A Chiller control RS232
described in direction 46-019668, Advantx System Facility Power and Ground Requirements
S 27126B ION CHAMBER B
K K
20A
X-Ray Tube Water Chiller RS232 (Innova 2100-IQ only) 28254A S
REVISIONS APPROVALS YY/MM/DD
Positioner
TITLE
Innova 2100-IQ/3100/4100 System MISMAPS REV
S 27677A Remote Control WATER OUTLET 27666A W REV MADE BY DATE PCN NO. DESCRIPTION MADE

1 HENRY C 18-Dec-07 - -
with standard Monitor Suspension
C2 - CABINET G P 1TB - AC POWER & GROUND WATER INLET 27667A NOTE: All sheets of this schematic will be at the same revision of this sheet. 2
CHECK
H. PLANTARD - FIRST MADE FOR: 1
3 APPR
-
The revision of this sheet will be the revision of the entire document. P. REMOT GE MEDICAL SYSTEMS 2347957-3-100 TPH
4
OTHER BUC 1 2
5 - - SHEET OF

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
** Connecting Details TECHNICAL ROOM
NOTE: Cable group either 4-1, either 4-2 and 4-3 could be extended with cable group 4-4 not
PDB Positioner C2 Electronics Cabinet (positioner) shown.
EXAM ROOM CEILING Connection 3/4 LCD Monitor suspension
20
Bulkhead 3
Room
BULKHEAD SYSTEM
24 m 36 m Box
Light Advantx LCA W/Bolus chasing 27083A P S
Control TB3 27682A S PDB On-Off CJ 512/1 28172 28173
DOSE DISP 2
S Dose Monitor Display 2 Legend:
21
Downscan supply CJ1 27684A P
A 14
Ground Room
Light 27686A S PDU On-Off CJ4
.
A
Switch
S W = Water Lines
(TSSC)
V VCIM console CJ712 27676A S 29183 28194
DOSE DISP 1
S Dose Monitor Display 1 = Signal Cables
15 27685A Downscan in CJ3
TB2 .
Without Fluoro UPS V
Shield 1 27678A S Downscan out CJ2 27495A V = Video Cables I = Internal Cable
12 2
X-Ray ON With Fluoro UPS RT Bus CJ301 BW 1 Location
13 3
28259A S
3 mon 28066 28067 BW-1 H = High Voltage Cables
18 Shield 4 Modular PDU/C2 V Live Fluoro Monitor
5
C2 power 3 Phases
from PDB (For US only) 4 mon 28070 28071
34 = Cable Run Numbers
X-Ray Power ON
Lamp 6 G P Elegance power cable TB602
27660A
P nd
2 shielding P = Power Cables
3 Phase 400V and GND 27661A
19 Shield 7 SUSPENSION
GROUND
16 8 24 V 27680A G P FL2/CB4 2 wires AC
27675A P 3 / 4 mon 28189 28190 G = Ground Wires FS = Field Supplied Cables
9 power cable CB600 G
X-Ray
Lamp
C2 power 3 Phases
from C1 (Not for US)
4-4 MONITOR (Independent of
Door POWER
17 Switch 3 / 4 mon 28186 28187 P Monitor Suspen Pwr Strip Power Cables)
11198A = MIS Numbers
BULKHEAD TABLE
B BW 2 Location B
27683A S Debug J18 WARNING: Prior to 28068 28069 BW-2
3 mon
each installation, V Roadmap Monitor
100 wires signal table data #1 BJ400 27672A S ensure that the ECG 4 mon 28072 28073
27679A S Ge Bus / Arcnet DJ23
power cable is 2nd shielding or = Not included in GTC
100 wires signal table data #2 BJ201 27673A
connected to a line that BW 3 / Color 1 Location
Door Interlock TB2 25 wires UIF table power data BJ403 27674A P is protected against POWER ECG
See Connecting HOSPITAL 3 / 4 mon 28120 28121 P
Details ** short circuit hazards, UPS LINE ECG Display Monitor OR
X Ray On Light TB2
24 wires Motor power AJ200 27669A P according to local or = Optional Selectable in GTC
ECG Control 3 mon 28045 28046
15 wires signal cable AJ300 S regulations and that Unit COLOR 1
27670A OR V AW Monitor OR
27681A G BOLT the ECG monitor is AW Video
4 mon 28047 28048
100 wires signal cable data AJ 202 Splitter
Remote Access Modem Line
27671A powered according to CONTROL BOOTH
IEC60601-1 BW-3 Dose Monitor Control
DL Video
Splitter 4 mon 28076 28077 V
BW3 Monitor - 4TH 29183
Local Phone Walk Plug (DIRECT) 27587A requirements (leakage J32 / J1B Option S 28194 DISPLAY
current and
C grounding).
nd
2 shielding
S 27126A ION CHAMBER A
C
Fluoro UPS I/F box (Innova 2100-IQ only) BW 4 / Color 2 Location S 27126B ION CHAMBER B
Fluoro UPS (Innova 2100-IQ only) With Fluoro UPS POWER ECG
S 28259A J2 RT-bus C2 cabinet HOSPITAL 28120 28121 P
4 mon ECG Display Monitor OR
With Fluoro UPS UPS LINE Bolus Wallbox
UPS control 28257A S S 28257A J3 UPS control
ECG Control ADVANTX LCA W/BOLUS
With Fluoro UPS Unit COLOR 2 P S 27083A
S 28258A J4 PDB control
OR 4 mon 28049 28050 V CHASING
Ethernet 28262A S With Fluoro UPS AW Video AW Monitor OR
S 28260A J1 RT-bus C1 cabinet Splitter
S 27041A INNOVA W/BOLUS CHASING
With Fluoro UPS Control Booth Roadmap
EPO/ON/OFF 28256A S G 28261A Bolt BW-4
DL Video BW4 Monitor - 3RD Monitor
Splitter 4 mon 28074 28075 V
J28 / J1A Option V 27500A VIDEO IN
2nd shielding
Hospital C1 Electronics Cabinet (system)
3 / 4 mon I/R RECEIVER DL Infrared
Main Power With Fluoro UPS
Ethernet HUB
Ethernet RJ POS J5 S
28195 28196 S
Remote Receiver Accessories Video Peripheral
D S 28262A Ethernet (Fluoro UPS) 27662A
V D
3 x 380 to
By Pass
Rectifier

27495A VIDEO IN
Output

P 27531 Mains HUB (UPS) RJ45 for FE Laptop J8 27505A S


CAUTION: The second shieldings of BNC cables (BW-1 through BW-4) are connected as follows: S
- Cabinet side: connected to the Ground BAR. 27496A REMOTE CONTROL
480 VAC Modem with DC Bloc KVM - Suspension side: connected to the connection Box at the point labeled “Suspension Ground”.
AW Video Splitter
27587A S Modem phone line J16 Keyboard, VGA, Mouse extender J6 27493A S 28045 ...
...28050
P 27532 Mains Modem (non UPS)
AW Workstation Central Unit
Live Monitor Option V
DL & Video Splitter 28066/28067
DL video live monitor J26
28070/28071
V With keyboard and mouse
4-2 V P G 27501A VIDEO IN/AC/
Power Distribution V 27687A LCD Red J41
DL video Rdp monitor J30 28068/28069 AW Power Strip P
Box (Wall PDB) V 27688A LCD Green J42 28072/28073
V To 230Vac
4 OUTLETS
LCD Blue J43 28195
With Fluoro UPS V 27689A DL Infra Red Receiver J15
28196 S AW Workstation Monitor #2
Fluoro UPS EPO/ON/OFF 28256A S
V 27690A LCD H Synchro J44 27501A VGA
3rd Monitor Option J28.J1A V P G
E V 27691A LCD V Synchro J45
28074/28075 Roadmap Monitor Option P
E
With Fluoro UPS
PDB control 28258A S
27502A 4-3
V 27685A VCR Video KX6 J24 4th Monitor Option J32.J1B
28076/28077 V P G V P G 27502A VIDEO IN/AC/ AW Workstation Monitor #1
Control Booth Power Strip V VGA
P 27533 Mains Video splitter (non UPS)
System ON/OFF Loop 27682A S
P
P 27458 Mains DL (UPS)
P 27472A 5 OUTLETS P
Provided by installator VCR Control J13 27496A S
JEDI POWER 3 Phases P P 27526 Mains Fan (UPS) P
2
27683A S Debug COM6 J40 Video Main KX6 cable J27 27492A V
Provided by installator P
Main Ground Wire G 27686A UPS Stop (Zephir Board)
DL Keypad J14 27494A S Secured Power
J10 GEMNET Plug
C2 power 3 Phases Provided by installator Strip 3 RED OUTLETS P
(For US only) P G
Video Slave KX6 Rdp J31 27500A V EXAM ROOM FLOOR Injector ACIST Injector/ 10906B/
RT Bus (Gitane Board) G
PDU/C2 power 3 Phases LF Angio Illumina Pedestal Injector 10908B
(Not for US) Provided by installator With Fluoro UPS
PDU 2 Phases P G 28260A P
10907B S
F (for US only) RTAC Universal Interface (LF Angio Illumina Pedestal Injector)
F
Without Fluoro UPS
Same as KVM - R Mouse
Emergency UPS Stop 27561A S 27678A
S H1C RT Bus (Gitane board) J22

27679A S Ge Bus / Arcnet J23


Fiber Channel J7 27512A S ECG Acquisition Head S 27493A
Provided by installator
DL Keyboard
Chiller 3 Phase P G 27523A S Detector Chiller Control J17 S 27567A Data Reserved
Detector power CAN Bus J11 27514A S
P 27459 Mains RTAC (UPS) DL Flat Panel
1
Vascular Table (Omega or Elegance)
S 27693 CAN & RT lines 15 pins J1 V 27687A J41 LCD Red

Door Light P 27660A Elegance power cable V 27688A J42 LCD Green
System ON 27661A P
JEDI V 27689A J43 LCD Blue
X-Ray tube stator cde DJ2 27664A S S 27662A RJ45 Ethernet Injector (J2) 10907B S
S 27693 CAN 15 pins J6 X-Ray tube temp switches DJ3 27665A V 27690A J44 LCD H Synchro
* Connecting Details S 10906B/
G 27468A BUS BAR L BUS BAR G
G (Not for US)
P X-Ray tube Ingrid DJ1 27663A
10908B V 27691A J45 LCD V Synchro
G
27473A BUS BAR
TB02 Innova 3100/4100 27041A P S
Anode I+ 27589A H w/ Bolus chasing only
3x 160A S 27672A J600 Table Data #1
AWG6 Cathode I- 27590A J601 Table Data #2
27673A Control Booth Live Monitor
2347573

AWG6
Jedi S 27677A X-Ray Tube Chiller Control DJ4 RS232 J3 (Generic IF Board)
AWG6 (Innova 2100-IQ only) 27701 P
LVPS 400 Oil Pump P 27674A J605 Table Pwr Data
Relay command V 27492A VIDEO IN
FUSE BOX Power
PDB

P/N 2364241 27675A AC IN / TB1 (1-2)


STRIP UPS 27702
27694
16A strip box P 27513A DET. POWER MAINS J1
J47 Bulkhead
AWG10 AWG12 Strip box #3 ( new ) VCIM On-Off Console with
2315513

S 27514A DET. PW CAN J2 L BUS BAR 27470A G


2358531

AWG10 AWG12
STRIP NON UPS Handswitch
28245 L BUS BAR
PDU P/N 2305956-2
strip box P 27722A DET. PW OUT J3 27471A
27550 27549 27546 S 27676A Signals and 24Vdc
AWG10
AWG10
AWG10

27722A
PDU & BUS BAR Opto-
Bridge 28254A S
H 28261A J8 LC Gantry H
G BUS BAR J3B J5 J1A DL Keypad
C1-
C1-CABINET Not used Non UPS Output UPS Output Non UPS Output 27586A DETECTOR
G 27468 BUS BAR L BUS BAR S 27494A Serial Link with Power
2350103 P 27586A Detector Supply 27470A G
J4A Downscan supply 27684A
AWG10

AWG10

AWG10

Optic fiber L BUS BAR 27471A


20A
G BUS BAR from PDB S 27512A w/ bulkhead
J3A Detector AC 27513A P
C2 power 3 Phases
power supply
W 27511A Detector water FE Laptop
Positioner (Not for US) pipe in flow
BUS BAR 27468A G Detector water L BUS BAR 27030 G
C2-
C2-CABINET 27680A 2 Phase PDU 27510A
pipe out flow S 27505A NO BULKHEAD (Free)
See Connecting Details * 27473A
BUS BAR
P TB02 3 Phase 400V CB1
TUBE
* Connecting Details J4B/J2A Strip AC
BUS BAR 27472A P G W 27666A X-Ray tube water GND
(For US only) pipe out flow 27030 G
S 27561A Emergency UPS Stop J17
27667A X-Ray tube water ECG Control Unit (Optional)
J9 Strip AC 28186 pipe in flow
G 27681A BUS BAR P
BUS BAR 28187 H 27589A ANODE I+ S 27560A Data Reserved
J TB02
3Ph to C2 J
28189 G 27590A CATHODE I- 24 m
3x 160A
36 m
AWG6 28190
27686A S 27686A PDU ON/OFF J20 S
2347573

AWG6 27664A X-ray tube stator cde J1 SUSPENSION 3 mon 28045 28046
AWG6
Jedi CONNECTION
P 27522A
Detector Conditioner Power J3B 27665A X-ray tube temp status BOX
FUSE BOX
COLOR 1 4 mon 28047 28048 V VGA
PDB

P/N 2364241
27663A X-Ray tube ingrid

16A J100 Power SUSPENSION 4 mon 28049 28050


AWG10 AWG12
P 27669A motor CONNECTION
BOX
2315513

Detector Conditioner COLOR 2


2358531

AWG10 AWG12
S 27670A J206 Collimator
PDB

PDU P/N 2305956 - 2


WATER INLET 27510A W 27671A J205 Data LC
P 27522A Chiller AC power 3 wires
AWG10

AWG10

WATER OUTLET 27511A CAUTION: For proper operation and regulatory compliance, it is mandatory to follow the guidelines
S 27523A Chiller control RS232 S 27126A ION CHAMBER A
C1 - CABINET described in direction 46-019668, Advantx System Facility Power and Ground Requirements
S 27126B ION CHAMBER B
K 3 K
20A
X-Ray Tube Water Chiller RS232 (Innova 2100-IQ only) 28254A S
REVISIONS APPROVALS YY/MM/DD TITLE
Positioner S 27677A Remote Control MADE Innova 2100-IQ/3100/4100 System MISMAPS REV
WATER OUTLET 27666A W REV MADE BY DATE PCN NO. DESCRIPTION
1 HENRY C 16-Dec-07 - with LCD Monitor Suspension option
C2 - CABINET G P 1TB - AC POWER & GROUND WATER INLET 27667A NOTE: All sheets of this schematic will be at the same revision of this sheet. 2
- CHECK
H. PLANTARD - FIRST MADE FOR: 1
3 APPR
-
The revision of this sheet will be the revision of the entire document. P. REMOT GE MEDICAL SYSTEMS 2347957-3-100 TPH
4
OTHER BUC 2 2
5 - - SHEET OF