You are on page 1of 25

GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

GE Medical Systems

Technical
Publications

Revision 2

Revolution ACT
Service Intro Planner (iSERV)
THIS MATERIAL IS THE PROPERTY OF GEMS AND CONTAINS
INFORMATION THAT IS RESTRICTED TO USE BY GEMS
MANUFACTURING, ENGINEERING AND SERVICE PERSONNEL. ANY
REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.
NEITHER THIS MATERIAL NOR ANY INFORMATION CONTAINED
HEREIN SHALL BE DISCLOSED TO ANYONE OUTSIDE OF GEMS
MANUFACTURING, ENGINEERING AND SERVICE PERSONNEL.

Copyrighted © by General Electric Company, Inc. 2018

LEGAL NOTES
MADE FOR: Revolution ACT (SVCT16)
iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 1 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

GE EXCLUSIVE USE ONLY


Restricted to General Electric Medical Systems (GEMS)
This material is property of GEMS and contains information that is restricted to use by GEMS Manufacturing,
Engineering and Service Personnel. Any reproduction in whole or in part is strictly prohibited. Neither this
material nor any information contained herein shall be disclosed to anyone outside of GEMS Manufacturing,
Engineering and Service Personnel.

TRADEMARKS
All products and their name brands are trademarks of their respective holders.

UPDATES NOTICE
This is information for service to inform service operations and service personnel about new program introduction.

COPYRIGHTS
All material, Copyright (c) 2017 by General Electric Company, Inc. All rights reserved.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 2 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

REVISION HISTORY

REV DATE PRIMARY REASON FOR CHANGE


1 Refer MyWorkshop Initial release
2 Refer MyWorkshop Add contents for Brazil release: 1, Add new PSI code for Brazil 2, Add updated
PCM for Brazil 3, Add training information 4, Add all new spare parts for
Revolution ACT.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 3 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

SERVICE INTRO PLANNER


Revolution ACT

TABLE OF CONTENTS

GE EXCLUSIVE USE ONLY .......................................................................................... 2

SECTION 1 − Objective.............................................................................................. 6

SECTION 2 − Introduction ......................................................................................... 6


2−1 Program Overview ..................................................................................................................................................... 6
2−2. System Configuration and Key Specs ........................................................................................................................ 7

SECTION 3 – Hardware Overview ............................................................................. 7


3-1 Gantry ......................................................................................................................................................................... 7
3-2 Console...................................................................................................................................................................... 11
3-3 Table ......................................................................................................................................................................... 12
3-4 PDU ........................................................................................................................................................................... 12
3-5 UPS ............................................................................................................................................................................ 12

SECTION 4 − Software Features .............................................................................. 12


4-1. Operating System (OS) and Applications (APP) ....................................................................................................... 12
4-2. Software Installation................................................................................................................................................ 12
4−3. Software DICOM Conformance ............................................................................................................................... 13
4−4. INSITE Checkout Information .................................................................................................................................. 13
4-5 Service Features and Improvements ......................................................................................................................... 14
4-6 SSA (Secure Service Access) Features ........................................................................................................................ 16
4-7 Graphical User Interface ........................................................................................................................................... 16

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 4 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

SECTION 5 – Catalog Structure and PSI Code .......................................................... 16


5-1 System Catalog Structure (Reference 5652523PCM Rev15) ..................................................................................... 16
5-2. System PSI Code ....................................................................................................................................................... 16

SECTION 6 – Installation and Maintenance............................................................. 17


6−1. Training ................................................................................................................................................................... 17
6−2. Service Documentation ........................................................................................................................................... 18
6-3. Class C and Class M Software .................................................................................................................................. 18
6-4. Service Tools / Diagnostics ....................................................................................................................................... 19
6-5. Periodical Maintenance ........................................................................................................................................... 19
6-6. Rooms and Siting ..................................................................................................................................................... 19

SECTION 7 – Spare Parts List................................................................................... 20

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 5 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

SECTION 1 − Objective
This service introduction planner is intended to provide all field regions with information regarding the Revolution ACT
product with 17BW35.13 software. This document describes the Revolution ACT legacy configurations and features as
well as the new enhancements and features associated with this product release.
 New Introductions and information
 Release of product to USA Market
 Z440 Operator Console (OC) (Section 3-2)
 Software (Section 4-1)
o Operating System: SuSe SLES 11 SP 3
o Applications: 17BW35.12
 Insite Checkout Information (Section 4-4)
 Service Features and Improvements (Section 4-5)
 Quality Fixes (Section 4-5)
 New Options : (Section 5-1)
o B75542KA SVCT Z440 ASiR with GPU (Z440 Options)
o B75542KB SVCT Z440 EnhancedRecon (Z440 Options)

The other (Revolution) ACT/ACTs iSERV for reference are DOC1729151, DOC1972156 DOC2028794.This service
introduction planner is not a service manual or users guide. It is a collection of information taken from several source
documents that are available.
If you have any questions or suggestions please contact MICT Engineering.
Contact person: Munish V. Inamdar; Ju Fengwei
E-mail address: munish.inamdar@ge.com; fengwei.ju@ge.com

SECTION 2 − Introduction
2−1 Program Overview
Revolution ACT product is a CT scanner based on Brivo CT385 platform which is compact and non-tilt 16 slice system
with 43cm FOV and 65cm diameter gantry bore. The main changes compared with Brivo CT385 are as follows:

- Djinn Tonix Generator


- Atlas16 Detector
- Super Value DAS/TGP/ORP

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 6 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

- New single monitor UI with SUSE OS


- Z440 Operator Console (OC)
- New Axial Motor
- Ethernet data transmission from Gantry to Console (No KDIP board)
- New calibration called GCAL made for Atlas detector
- New Graphical User Interface

2−2. System Configuration and Key Specs


The table below shows system configuration of the Revolution ACT systems:

System Cat # B75542GA B75542GC B75542DH B75542BA


Global (except Brazil Only
Shipped to Only China Only Japan
China and Japan)
Manufacture Place GEHW GEHW and Brazil SKD

Product Name Revolution ACT


Std. Minimum Scan Time (sec.) 0.984
Std. Max. mA 200
Std. Slice Thickness 16 x 1.25
Std. Helical Capability (sec.) 90
6 (43 FOV)
Std. Max Recon Speed (fps)
16 (43 FOV, with GPU)
Interchange Media DVD
Tube (MHU) 2
Linux RAM (GB) 16
PDU(NGPDU) (V) 200-480
Image Storage Capability (GB) 300GB
Table Movement (mm) 1200 with axial head holder
Raw Data Storage Capability (GB) 500GB
Table Up/Down Yes

SECTION 3 – Hardware Overview


3-1 Gantry
Revolution ACT Gantry is based on Brivo CT385 Gantry:

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 7 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

- Patient Aperture: 650mm±5mm


- Tilt: Digital Tilt
- Maximum SFOV: 43cm
- Rotational Speeds: 360° in 0.984, 1.0, 1.2,1.5, 2.0, 3.0, 4.0sec
- Focal spot to detector distance: 949±1mm
- Focal spot to iso-center distance: 541±1mm

TGPSV board in Gantry:

TGPSV board is newly designed TGP for Revolution ACT. TPGSV is combined the functions from TGPG and KDIP card so
that this board not only manages the gantry control but also manages the raw data transmission from DAS to OC. Also,
the service switches are integrated into TGPSV which is legacy concept from Brivo CT315/325. TGPSV can support
Kunlun Table and LingLong table. The main function of TGPSV are as follows:

 Scan Data Transfer, TGPSV picks up the scan data from the slip ring RF fiber through J10, repacks the data to
TCP/IP and sends the data to OC through J3.
 Cover Interface, the gantry cover houses control/display panel, e-stop/e-reset buttons. The gantry microphone
signals are connected to TGPSV for corresponding functions.
 SCBSV Connection, the scan control box is connected to TGPSV for any scan command and e-stop/e-reset
communicate with gantry. Also, TPGSV supplies 24VDC power to SCBSV.
 PDU Interface, TGPSV has one PDU interface connected to PDU control board. TGPSV can send out commands to
PDU to control contactor close or open mode. TGPSV can collect the feedback signal from PDU to know whether
PDU working normally.
 Gantry Thermal Control, TGPSV collects gantry temperature data from the detector air sensor and controls the
gantry fan to adjust the gantry internal temperature.
 Table Control, TGPSV collects the table POT feedbacks and controls the table up/down (only for Kunlun Table),
cradle movement and latch/unlatch.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 8 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

 Axial Driver Interface, TGPSV reads the motor encoder feedback and gives the control command to axial driver to
enable gantry rotation and static brake.
 Energy Saving Mode, TGPSV cuts off power to the rotating parts when the system enters the energy saving mode
by sending command to PDU control board. Also, TGPSV sends re-power command to PDU when the system quits
energy saving mode.
 MSUB Function, TGPSV manages the exposure sequence by working with ORPSV to SYNC gantry rotation, table
movement, X-ray exposure and data acquisition.
 Service Switches, the service switches include 120VAC ON/OFF, Axial Drive ON/OFF, HVDC ON/OFF, SYS/MNL,
JOG/CNT, HIGH/LOW.

ORPSV board in Gantry:

ORPSV is a newly designed on-board rotation processor for Revolution ACT, and is the central communication point for
rotating subsystems in gantry. The main function of ORPSV is to manage the exposure sequence, control collimator
movement and the interface between generator and other subsystems. Also, ORPSV will control the alignment lights.

Djinn Tonix Generator:

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 9 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

Djinn Tonix Generator is a newly designed generator for Revolution ACT with 24kW capability. It can support
80kV/100kV/120kV/140kV and Max 200mA for application mode. Djinn Tonix is simpler when compared with JEDI and
includes one power module, one HV Tank and one DC Filter, detailed function as below:

 Power Module: Inverter, KV driver, mA driver, rotor driver and interface board are all inside this power module.
 HV Tank: HV silicon rectifier stack and filament transformer are all in this Tank.
 DC Filter: EMC filter for DC input power.

Atlas16 Detector:

Atlas16 detector is based on the current DoD detector but with bigger modules than DoD. Atlas16 detector has 6
modules and each module has two sides (A-side and B-side) with 136 cells or pixels per module per slice/row. Cells are
labeled A1/B1 through A8/B8, for a total of 16 rows across the detector face (both A and B sides) in z azimuthal

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 10 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

direction. Same as DoD detector, Atlas16 detector can convert X-ray to digital raw data signals in the module and then
send the digital signal to DAS. Each module uses one signal cable connections to the data acquisition system (DAS)
backplane board. Atlas16 detector has better thermal designs compared with DoD detector hence the heater/blower
which are used in Brivo CT385 gantry are not required for Revolution ACT.

New calibration called GCAL (Geometric Calibration) introduced for Atlas detector.
SVDAS:

To support the new detector, a new DAS is designed for Revolution ACT. SVDAS include one DCB board and one
backplane Board.

Tube:

2.0M Venus Tube which is used in Brivo CT385.

Collimator:

H4 collimator which is used in Brivo CT385.

Covers:
Same covers as those used in Brivo CT385 expect with different colour.

3-2 Console
Z440 Console

HP Z440 computer is a standalone computer with chassis. There is no tower for this computer. The computer will
receive power from the console UPS. The console UPS receives its power directly from PDU. HP Z440 computer will be
connected to a single wide screen monitor. HP Z440 computer will use the existing monitor, mouse, keyboard and
SCBSV. HP Z440 configuration is as follows:

Processor Xeon E5-1620 v3, 3.5 GHz, 10MB Cache, 4 cores, 130W, MBW 68GB/s
16GB as 2x8GB
Memory
DDR4 8GB ECC 288-Pin Registered DIMM, 2100 MHz or higher
Two HP 512GB SATA 6GB/s 7.2K rpm Hard Drives Disk (HDD)
HDD make options: Toshiba, Seagate, Western Digital
ONBOARD SATA DEVICES
HP DVD/RW Drive, 9mm, 8X

Power Supply 700W

BIOS version v2.23

SLOT 1 PCIe Gen2 x1 Not used – open

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 11 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

SLOT 2 PCIe Gen3 x16 AMD Firepro W2100 Graphics Adapter (Display)

SLOT 3 PCIe Gen2 x4 Intel I350T2, Dual Port Gigabit Ethernet PCIe Card

SLOT 4 PCIe Gen3 x8 Not used – open

SLOT 5 PCIe Gen3 x16 AMD Firepro W4300 (recon accelerator option)

SLOT 6 PCI 32bit/33 Not used – open

Other Devices Front Chassis Fan Kit, DP to DVI adapter cable

The output of W2100 graphics card is DP. Hence a separate DP-DVI cable gets shipped along with HP Z440 computer.
The monitor gets shipped with a DVI-DVI cable. The monitor gets connected to HP Z440 using these two cables. For
details, refer the training document DOC2023388. The Ethernet data transmission is from Gantry to Console without
KDIP board.

3-3 Table
Revolution ACT uses Kunlun table which is same as Brivo CT385.

3-4 PDU
Revolution ACT uses NGPDU series which is similar as Brivo CT385.

3-5 UPS
Revolution ACT supports 1-phase standalone UPS option. This UPS is like the one used in Brivo CT385 and uses the same
chassis as Brivo CT385. The inside chassis of the UPS is supplied by another supplier and the setup procedure differs
from Brivo CT385. The detailed method of this new UPS installation and setup can be found in the service manual.

SECTION 4 − Software Features


4-1. Operating System (OS) and Applications (APP)
OS and Application version are as follows:

OS: SuSe SLES 11 SP3


Applications: 17BW35.13

4-2. Software Installation


Software are listed below; Class C and Class M software will be distributed via 1Touch Point. Please order the ones
manufactured in the USA.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 12 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

Part Number Part Number Description Where to find


(Made in China) (Made in USA)
5778368 5778368-10 SUSE OS Shipped with every system
5788409 5788409-10 Application for Revolution ACT/ACTs Shipped with every system
NA 5788929 Class C Software Order from TAB 182
NA 5788928 Class M Software Order from TAB 182

It is important to select the correct OS profile (GEHC-SV) for HP Z440 computer during Load from Cold. Incorrect
selection will lead to the error message which will prompt OS installation with correct OS profile (GEHC-SV).

4−3. Software DICOM Conformance


Software DICOM conformance is released in MyWorkShop through DOC1959285.

DICOM document can be accessed via the following link:


http://www3.gehealthcare.com/en/Products/Interoperability/DICOM/Computed_Tomography_DICOM_Conforma
nce_Statements

4−4. INSITE Checkout Information


This product uses version 4.5.4 of IIP software.
Select the appropriate model type for the InSite Checkout.
Product Line: Helios
Model Type for Checkout: _SUSE_IIP4.5

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 13 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

4-5 Service Features and Improvements


The features incorporated in Revolution ACT have been carried forward. The following new service features are being
introduced:

• IIP > 4.5


• Image database remaining size manager
• Detect system scanning status, prevent sweep when system is scanning
• 16 digital system ID
• Recon performance (fps measurement)
• NEMA XR 26

The following SPRs were fixed when HP Z440 was structured into (Revolution) ACT/ACTs products (DOC2028794). The
same have been carried forward in 17BW35.13.

SPR Number Description


HCSDM00465376 [SVCT16 Global]: The Dynamic Transition Issue with European language
HCSDM00469465 Issue: Scout not transferred automatically to the archiving servers
[SVCT16 Global]: After the actual scan, the description we saved by each
HCSDM00465383
scan series on the protocol management doesn’t apply
[SVCT16 Global] - End Location scan parameter cannot be modified for 1
HCSDM00467605
scout scan after reboot
[SVCT16-Global]: On reconfig page units for patient height parameter reset
HCSDM00447064
to “US”, even though last selected was Metric
HCSDM00440696 [SVCT16 Global]: Application Re-order not working in ImageWorks
HCSDM00467413 [SVCT16 Global]: Translation Issues for Italian Language
[SVCT16-EOL] changing the timeout value between TGP & Axial Drive to
HCSDM00469469
650ms
HCSDM00469470 [Tigre->SVCT] KL Table can't move down to home position intermittently
HCSDM00471363 [SVCT16] Gantry reset failed after energy saving sometimes

The following service manual related SPRs were fixed.

SPR Number Description


HCSDM00398353 To Revise Service manual for line regulation from 4% to 6%
HCSDM00441825 [SVCT16 global] Request to update Service manual to add 30kVA MHLW
System rating plate adhering if system is 30kVA
HCSDM00444472 [SVCT16] Need to add Definition of E01&E02 in Service Manual
HCSDM00460940 Detector error handling update

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 14 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

HCSDM00405072 Service manuals needs to update to align with new Minicheck tool
design(180 degree and 90 degree scan)
HCSDM00478685 Update TP about connect host and monitor
HCSDM00483563 The issue of power off description of SVCT LFC

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 15 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

4-6 SSA (Secure Service Access) Features


SSA generation2 is used for Revolution ACT. The classification is based on Brivo CT385 in Tang program.

SSA Cat # Description


R252AC Standard Level 2 service package delivered for the warranty period
R253AC Standard level 3 service package delivered for the warranty period
R252AB Standard Level 2 service package delivered for 1 year
R253AB Standard level 3 service package delivered for 1 year
R252CB Advanced service package level 2 for 1 year
R253CB Advanced service package level 3 for 1 year
R251CB Advanced service package level 1 for 1 year
R251CA Advanced service package level 1 for 20 year

4-7 Graphical User Interface

New graphical user interface has been introduced for Revolution ACT products.

SECTION 5 – Catalog Structure and PSI Code


5-1 System Catalog Structure (Reference 5652523PCM Rev15)

Please double click below document and open the latest PCM to find system catalog structure.

PCM for
ACT_ACTs_Revolut

5-2. System PSI Code

PSI code Description BCAT No. Shipped to


CSEC15 REVOLUTION ACT BJG SKD BRAZIL B75542BA Only Brazil
CSEC14 REVOLUTION ACT SVCT16 BEIJING B75542DH Global (Except China and Japan)
CSEC14 REVOLUTION ACT SVCT16 BEIJING B75542GC Only Japan
CSEC12 REVOLUTION ACT SVCT16 BEIJING B75542GA Only China

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 16 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

SECTION 6 – Installation and Maintenance


6−1. Training
With the introduction of 17BW35.13 and HP Z440 computer, the related training documents DOC2044413 and
DOC2047741 are released through MyWorkshop. The CBT form of these trainings are now available via GSU at
https://www.gebrilliantyou.com/global-services-university/mict?tab=ct. Upon visiting this website, scroll down to find
the trainings in the NPI section.

Short-term solution:

-The FE’s from the USA will be trained by a Senior Service Leader from India during the first installation of Revolution
ACT at a site in California.
-Continuous Training Updates (CTUs) were developed for the (Revolution) ACT/ACTs systems as follows and will be used
for those who FEs who are “L1 AND L2” trained (plus experience in Field) or Proficient CT training:

L1-CT Continuous Training Updates: Q4 2015 - Class C


GEHC-GSTD-CTUCURR-L1-1600-2015-Q4
• Identify hardware configuration differences
• Operate the Single Monitor User Interface

L2-CT Continuous Training Updates: Q4 2015 - Class C


GEHC-GSTD-CTUCURR-L2-1601-2015-Q4
• Identify the Super Value: DAS/TGP/ORP
• Perform Djinn Tonix Generator Diagnostics
• Perform Gantry Balance Procedure
• Perform Slip Ring Radial Position Adjustment
• Perform Receiver Assembly Adjustment

L3-CT Value Continuous Training Updates: Q4 2015 - Class C


GEHC-GSTD-CTUCURR-L3-1605-2015-Q4
• Troubleshoot the Atlas Detector on Revolution ACTs
• Replace the Collimator on Revolution ACTs
• Replace the Slipring Platter Assembly on Revolution ACTs

Brivo CT385 Computer Based Training:


GEHC-TT-50153840_CURR

-For Brazil SKD, training plan follows below:


CBT described above with support / guidance from HCI LATAM Instructor and SQS released by HCI.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 17 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

Long-term solution (all Regions):

-Improved web based training (CTU) for those who are already Brivo CT385 or Proficient qualified (training scope and
codes under revision by HCI – TBD).
-Proficient training (either HCI or ATC based) followed by web based CTU.
-Proficient Field based training with certified HCI Instructor in Latin America in Contagem (subject to EHS / Regulatory
conditions plus production schedules to provide equipment availability).

6−2. Service Documentation


The following Service manuals have been formally released:

Direction(P/N) Title Class


5487127-1EN SVCT-16 Pre-Installation Manual A
5487205-1EN SVCT-16 Installation Manual A
5604148-1EN SVCT-16 De-Installation Manual A
5487206-8EN SVCT-16 Series Service Methods HTML Publication_Gen A
5487207-8EN SVCT-16 Series Service Methods HTML Publication_Adv C
5487206-2EN SVCT-16 Series Service Methods CD-ROM_Gen A
5487207-2EN SVCT-16 Series Service Methods CD-ROM_Adv C

6-3. Class C and Class M Software

Part Number Description


(Made in USA)
5788929 Class C Software
5788928 Class M Software

Class C/M software will be distributed via TAB 182. Please order the one manufactured in the USA.

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 18 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

6-4. Service Tools / Diagnostics


The following part is shipped with system:

Tigre installation template, GEHC part number 5414624 (for table and gantry positioning on the ground)

Special tools are listed below,

Description Part Number Comments Where to find


Djinn generator This is used for: No load KV test/replace Service tool warehouse
5537222
troubleshooting kit generator/troubleshooting
Used to mounting the control panel
Display panel support 5409474 Shipped with system
when remove front cover
Used for Geometry calibration after
SVCT GCAL Jig 5604181 Shipped with system
alignment
Used for rotational No load KV test to fix
SVCT HV Tank Jig Asm 5492064 Shipped with system
the HV cable
5445679
Loop back jig Used for DCB loopback diagnostics Shipped with system
Mounting Module PIN 5554636 Used for removal and install detector
Shipped with system
module
Tigre Gantry and
This kit contains laser and other tools for
Table Alignment Tool 5452797 Service tool warehouse
table-gantry alignment
Kit

Note: For Revolution ACT, can reuse the Table Gantry alignment tool for Brivo CT385 and Revolution ACTs.

6-5. Periodical Maintenance


Refer to PM section of Service Methods CD (5487206-2EN and 5487207-2EN) for detailed information.
Revolution ACT periodical maintenance will be 3 times/year and minimum one time within warranty (Schedule W) as a
part of Global strategy. Service notes SN1962664 for periodical maintenance and SN1962672 for Schedule W are
released in MyWorkshop. The related PM forms are now available in the service manuals.

6-6. Rooms and Siting

System Head Holder Suggested / Typical Room Size Minimum Room Size
Included
(Yes/No)
Revolution ACT Yes 4700mm * 3633mm (15.4 ft * 11.9 ft) 4417 mm * 2473 mm (14.5 ft. * 8.1 ft.)
(Up/Down (PDU in Scan Room)
Table) No 4100 mm * 2473 mm (13.5 ft. * 8.1 ft.)

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 19 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

4700mm * 3183mm (15.4 ft * 10.5ft)


(No PDU in Scan Room)

SECTION 7 – Spare Parts List


This section will the list the spare parts that are released for Revolution ACT. You also can find all FRUs in FPC.

Part Number Detailed Part Description Sub


System

6030204 SCVT BP PWA Gantry


6030200 SVCT DCB PWA Gantry
5510990 TGPSV PWA Gantry
5665662-2 ac cable without line filter Gantry
5665663 SVCT DAS power output harness Gantry
5437621 SVCT8 and SVCT16 ORP PWA. Gantry
5432004-2 Cable from Axial Driver X10 to Motor Gantry
CN2
5451803 Regen resistor and power supply ASSY Gantry
for KC1-M,from axial driver X3 to Power
supply
5436456-2 motor power cable Gantry
5432005-3 SVCT Cable From Axial Driver +24VDC IN Gantry
to Axial Driver X1 and Static Brake

5432001-2 SVCT Cable From Axial Driver ASSY RL1 Gantry


to Axial Driver X7,X8,X9,X12

5340729-3 Cable from TGPSV J14 to Control Panel Gantry


RL
5645003 From TGPSV J17 to home flag Gantry
5645002 From TGPSV J23 to Gantry E-Stop Gantry
2293409-6 Fiber SR receiver to TGPSV J10 Gantry

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 20 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

5120636-4 Cable From TGPSV J4 to Slipring J7 Gantry

5428232-3 From TGPSV J3 to Powerpan LAN Gantry


interface
5428232-2 From TGPSV J2 to PowerPan LAN Gantry
interface
5645007 From Gantry PS to TGPSV J1 Gantry
5645020 cable from TGPSV J13 to GFHC BD J1 Gantry

5432000-4 Cable From TGPSV J29-2 to Axial Drive Gantry


Assy RL1
5453665 Djinn Aux power cable Gantry
5441917-2 stator and thermal cable for DJINN Gantry
5452851 SVCT-DAS DIGITAL KVMA Cable from Gantry
djinn to orp
5452860 Djinn HVDC POS+ Gantry
5441088 Djinn HVDC NEG- Gantry
5665666 ORP_CCB Power cable Gantry
5665665 DAS control Power cable Gantry
5665661-2 DAS AC CABLE for DIRECTING CABLE Gantry

5323975-3 scan window-3 Tigre Gantry


5422455-2 Cable from SVCT Control Display, MIC System
and ESTOP to Front cover RL Cable
5120646-4 SVCT Short Cable - PDU J9 to TGP J11 System
Cable
2343529-3 SVCT SHORT CABLE, HVDC FROM PDU System
TO GANTRY Cable
5645006-2 SVCT Short Cable From SVCT TGPSV J9 to System
SCBSV Cable
5645021-2 LAN cable for SVCT - From PowerPan to System
OC, 1000M Cable
5645022-2 LAN cable for SVCT - From PowerPan to System
OC, 100M Cable
5441518-3 GND cable - Console GND to Raceway System
GND for SVCT Cable
6451803 from power pan to line filter Gantry
6030209 rcib1, orp to das, with ferrite for SVCT-- Gantry
RoHS

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 21 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

5435259-2 Cable from TGFHC BD J4 to top fan relay Gantry

5448596 HV cable Anode, SVCT gantry Gantry


5457156 HV cable Cathod, SVCT gantry Gantry
6030208 opto cable for SVCT DAS, 3000mm Gantry
5534468-101 atlas foam cover assy, FRU Detector
5449892-2 ADB communication cable, 600mm, suit Detector
to MOD1,MOD5,MOD6
6792002 Atlas Detector_ADB heater cable Detector
5505557-101 light shield assy A Detector
5505613-101 light shield assy B Detector
5543202 Atlas 8 16 Rail heater cable Dsub9. Detector
5494265 Atlas 8 16 Rail sensor cable. Detector
5449892-3 Atlas ADB communiction cable, 400mm, Detector
suit to MOD2,MOD3,MOD4.
5501354-101 Rail heater kit, middle Detector
2343530-3 SVCT SHORT CABLE, AXIAL DRIVE System
POWER FROM PDU TO GANTRY Cable

5645040 SVCT SHORT CABLE, PDU TO GANTRY System


120VAC POWER Cable
5645031-2 CABLE for SVCT,CONSOLE POWER FROM System
PDU Cable
5500445-101 module frame heater Detector
6511000-2 SVCT Scan Control Box
5495654 FRU Djinn Tonix HVTank Generator
5495652 FRU Djinn Tonix Power Module Generator
5498643 FRU Djinn Tonix DC Filter Generator
5499977 FRU Djinn Tonix Cable Set Generator
5495657 FRU Djinn Tonix Generator Generator
5448366-100 Detector Collimator Insulator Detector
5534467-101 Detector Rail Thermostat Detector
5501354-201 Rail heater kit, #6 Detector
5501354-301 Rail heater kit, #0 Detector
5494650-101 Atlas 8 16_Rail sensor Detector
5435257-2 CABLE, FROM GANTRY ps to TGFHCB J2 Gantry

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 22 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

2320265-3 850M slipring, value version for Gantry


2320265-2
2349587-4 Slipring Platter Assembly Gantry
2349588-2 SVCT slipring platter, remove connector Gantry
from 2349588
5120819-3 Brush Block Assy for SVCT slipring,power Gantry
brushtips reduction from 5120819-2

5645000 Cable From TGPSV J8 to Covers Gantry


5453615 Driver KC1-M00606 Gantry
5495767-101 Module light shielding foil Detector
5604181 SVCT GCAL Jig Gantry
5492046 SVCT Motor assembly Gantry
5481512 SVCT Power supply unit assembly Gantry
5492059 Fuse Box Assembly Gantry
5492061 Power supply harness aseembly Gantry
5483312-101 Module Plunger guide for fail safe Detector
5440736-101 ATLAS 16slice detector for FRU Detector

5480497 SVCT16 POWER PAN Gantry


5480161 12A 24VDC relay Gantry
5480162 6A 24VDC relay Gantry
5372113-2 CABLE - MSUB J26 TO TABLE FOOT Gantry
SWITCH
5413321-2 SVCT16_Front_Cover_Ass Gantry
5444502 SVCT16_panel assembly Gantry
5351076 M35-16 with FEM16 Gantry
5454981-101 16slice Atlas Module FRU Kit -Class 1 Detector

2334820-50 SVCT PDU control board PDU


5482280 S203-D16 breaker PDU
5487373 25A Circuit Breaker, 3P PDU
S203-D25
5120646-3 SVCT16 Long Cable - PDU J9 to TGP J11 System
Cable
2343530-4 SVCT16 LONG CABLE, AXIAL DRIVE System
POWER PDU TO GANTRY Cable

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 23 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

2343529-4 SVCT16 LONG CABLE, HVDC FROM PDU System


TO GANTRY Cable
5645040-2 SVCT16 LONG CABLE PDU TO GANTRY System
120VAC POWER Cable
5645050 LAN cable from Gantry to OC,100M System
Cable
5645051 LAN cable from Gantry to OC,1000M System
Cable
5645031 CABLE for SVCT16,CONSOLE POWER System
FROM PDU Cable
5486520 Cable - From TGPSV J22 to IPC J13 System
Cable
5486772 24V Power Cable - From GANTRY PS to System
IPC board Cable
5317258-2 SVCT POWER CABLE FROM INJECTOR TO System
PDU Cable
5454981-107 16slice Atlas Module FRU Kit -Reference Detector

5408476-2 SVCT left side cover Gantry


5408477-2 SVCT right side cover Gantry
5535299 SVCT16 with Linglong table install Template
template
5645006 SVCT Long Cable-From SVCT TGPSV J9 to Gantry
SCBSV
5496504 lip cover for SVCT16 system Table
5534153-101 ATLAS 16slice Rail assy FRU Detector
5454981-001 SVCT 16slice ATLAS Module, class0-FRU Detector
kit
5501354-401 16slice rail heater kit #6 Detector
5501354-501 16slice rail heater kit #0 Detector
6520002-2 SVCT-16 Console Host Assembly OC
6511000-2 SVCT Scan Control Box OC
8770000-130 PSU HP Z440 700W OC
8770000-128 HDD SATA 500GB 7.2K OC
RAM DDR4 8GB ECC Registered DIMM, OC
8770000-100
2133GHz or higher
8770000-115 ODD SATA DVD-RW 8x slim-line 9.5mm OC
8770000-129 NIC PCIe Dual Port 1GbE RJ45, i350-T2 OC

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 24 of 25
Revision 2
responsible for ensuring the use of the current version.
GE EXCLUSIVE USE ONLY SERVICE INTRO PLANNER – Revolution ACT

Technical Supplement

GPU PCIe AMD W2100 with qualified OC


8770000-127
vbios
GPU PCIe AMD W4300 with qualified OC
8770000-131
vbios
5763460 2-Button Scroll USB Optical Mouse OC
End

MADE FOR: Revolution ACT (SVCT16)


iSERV for Revolution ACT
GE Healthcare Proprietary
Any copy made from the electronic version will be considered an
DOC2056202
uncontrolled copy. Individuals with uncontrolled copies are Sheet 25 of 25
Revision 2
responsible for ensuring the use of the current version.

You might also like