AIR CONSUMPTION FOR ON - OFF VALVE

DOUBLE ACTING PNEUMATIC ACTUATOR TYPE


BOGASARI

PERFORMANCE DATA OPERATION TOTAL


DESCRIPTION DIA ONE MOP AIR CONSUMPT
NO. POSITION
(inch) CYCLE (Bar) SERVICE (L/cycle)
(Liter)

BERNOLLI
1 PNEUMATIC VALVE BERNOULLI 6 7 6 7.00 7.00 NO

UF 1/2 (PROCESS)
1 PNEUMATIC VALVE AT INLET 8 2.42 6 0.00 0.00 NO
2 PNEUMATIC VALVE AT OUTLET 8 2.42 6 0.00 0.00 NO
3 PNEUMATIC VALVE AT DRAIN 8 2.42 6 0.00 0.00 NC
4 PNEUMATIC VALVE AT INLET BACKWASH 8 2.42 6 0.00 0.00 NC

5 PNEUMATIC VALVE AT OUTLET BACKWASH 8


2.42 6 0.00 0.00 NC
6 PNEUMATIC VALVE AT BLOWER 4 1.33 6 0.00 0.00 NC

UF 1 (BACKWASH)
1 PNEUMATIC VALVE AT INLET 8 2.42 6 2.42 2.42 NO
2 PNEUMATIC VALVE AT OUTLET 8 2.42 6 2.42 2.42 NO
3 PNEUMATIC VALVE AT DRAIN 8 2.42 6 2.42 2.42 NC
4 PNEUMATIC VALVE AT INLET BACKWASH 8 2.42 6 2.42 2.42 NC

5 PNEUMATIC VALVE AT OUTLET BACKWASH 8


2.42 6 2.42 2.42 NC
6 PNEUMATIC VALVE AT BLOWER 4 1.33 6 1.33 1.33 NC

UF 2 (SPARE)
1 PNEUMATIC VALVE AT INLET 8 2.42 6 2.42 2.42 NC
2 PNEUMATIC VALVE AT OUTLET 8 2.42 6 2.42 2.42 NC
3 PNEUMATIC VALVE AT DRAIN 8 2.42 6 0.00 0.00 NC
4 PNEUMATIC VALVE AT INLET BACKWASH 8 2.42 6 0.00 0.00 NC
5 PNEUMATIC VALVE AT OUTLET BACKWASH 8
2.42 6 0.00 0.00 NC
6 PNEUMATIC VALVE AT BLOWER 4 1.33 6 0.00 0.00 NC

COMPRESSOR
1 PNEUMATIC VALVE AT BLOWER 3 1.33 6 1.33 1.33 NC
CLARIFIER
1 PNEUMATIC VALVE 1 2 1.33 6 1.33 1.33 NC
1 PNEUMATIC VALVE 2 2 1.33 6 1.33 1.33 NC
1 PNEUMATIC VALVE 3 2 1.33 6 1.33 1.33 NC
1 PNEUMATIC VALVE 4 2 1.33 6 1.33 1.33 NC

BELT FILTER PRESS


1 TB 750 6 0 6 0.00 0.00

SWRO
AP8-LE-30
1 SERVICE VALVE 6 10 6 10.00 10.00 NO
2 REJECT VALVE 6 10 6 10.00 10.00 NC

BWRO
1 AP8-LE-30 6 8 6 8.00 8.00 NO

59.9
TANK AIR CAPACITY SELECTED
L 62.9
TANK AIR CAPACITY SELECTED 62
CAPACITY SELECTED L/min 80
Pressure Max. Selected Bar 8.50