You are on page 1of 1

NOTES:

1 2 3 4 5 6 7 8 SY 9 10 11 12 13 14 15 16 ALL INFORMATION ARE INDICATIVE ONLY. THE


CONTRACTOR SHALL FURTHER DEVELOP THE DETAIL
BOUND 1600 1600
ARY LIN
E / PROP DESIGN INCLUDING EQUIPMENT SIZING, CAPACITY,
OSED R
OAD RESER
VE LINE QUANTITIES, PIPE SIZING, ETC.

EXISTING ESCALATOR & STAIR TO


BE DEMOLOSHED

EXISTING WALL

EXISTIN
G ROAD
R ESERVE
LINE 4-HR FIRE-RATED FIRE SHUTTER
UP 9 COMMON - BIN CENTRE
MP 1 :
RA IENT
AD
GR RETAIL GREASE ESCALATORS AND STAIRCASE TO
INTERCEPTOR BE INSTALLED ONLY WHEN UPN IS
TO OPEN FOR OPERATIONS

BOUNDARY LINE
RAMP UP LOADING/UNLOADING LOADING/UNLOADING
GRADIENT 1 : 8.38 (7.5 x 3m) (7.5 x 3m)
RAMP UP
GRADIENT 1 : 18
UESC05
SHOP 01
A.1

PR
DN TO B2 UP FROM B1 RETAIL PAHU

ESC 03

ESC 04

OP
UESC06

OS
L O A D I N G / U N L O A D I N G (7.5 x 3m)

ED
ST 12

RO
GRADIENT 1 : 16.6
UP

DN FROM 1ST
UST03

AD
RAMP UP

4200

RE
SE
RV
6000 UL03

E LIN
ST 10 SSL 10

E
4800
B SHOP 02

C RESTAURANT 01

STMV
SECURITY ROOM

UP
SSL HOTEL STORE ROOM
TEL

(NEW)
ST 09
B1
WR/HR

R-BIN CENTRE

ELEC Floor Opening


COMMON HT CONSUMER HOTEL COMMISARY
SWITCH ROOM RESTAURANT 10
KITCHEN
COMMERCIAL
5700
LIFT LOBBY 01 RESTAURANT 02

HT CSR RETAIL STORE

OWNER / APPLICANT

ST 01 UP UP ST 02

D
E ST/MV
ST MV

FFL 01 SSL 01

R-COMMON
COMMON PG ELECTRICAL SANI
WR/HR O-SPK R-ELECT R-TEL H-ELV R-ELV WR/HR DESIGN CONSULTANT
ERVE LINE

SUB STATION
SHOP 03 7000
TRANSFORMER

FFL-MV SERVICE SSL MV SERVICE

4500 4500
PG - SUBSTATION CORRIDOR CORRIDOR
ROAD RES

RESTAURANT 03

SX
ROOM

RAMP UP
OFFICE SERVICE LIFT HOTEL SERVICE LIFT
GRADIENT 1 :20
HOTEL SERVICE LOBBY LOBBY
RETAIL
Y LINE /

CORRIDOR COMMON
RISER ROOM SERVICE
LOBBY (NO COMMERCIAL
COMMON LV SWITCH COMMON TRANSFORMER
LV SWITCHRROM ROOM ROOM LIFT PIT
ACTIVITIES ARE ALLOWED)
BOUNDAR

HL-01 to 03
ARCHITECT
ST 07B
UP
SSL 07B
LIFT PIT LIFT PIT LIFT PIT LIFT PIT

F OL-11 & 12 OL-09 & 10 OL-19 & 20 OL-17 & 18


RAMP UP GR

VE LINE
ADIENT 1 :20

LIFT PIT SERVICE LOBBY

OAD RESER
RESTAURANT 09

BOUNDARY LINE
RESTAURANT 04

LIFT PIT LIFT PIT LIFT PIT LIFT PIT


OL-05 & 06 OL-07 & 08 OL-13 & 14 OL-15 & 16 STRUCTURAL ENGINEER

EXISTING R
RAMP UP SHOP 04
5500

GRADIENT 1 :20
ST 07A
LIFT LOBBY LZ HOTEL BOH SSL 07A

UP Meinhardt (Singapore) Pte Ltd


RAMP UP GR

168 Jalan Bukit Merah, #09-01, Surbana One


RESTAURANT 08
SINGAPORE 150168
RETAIL PAHU
TEL: +65 6273 5255 FAX: +65 6274 0788
AD
IENT 1 :15

ESC 01
H UNDERGROUND PROJECT
RESTAURANT 05
J 3800
ESC 02

FUEL STORAGE
PROPOSED MIXED-USE DEVELOPMENT COMPRISING
3800
OF A 63-STOREY TOWER BLOCK WITH A 2-STOREY
PODIUM FOR SHOP & RESTAURANT USE, 1ST STOREY
ST 03D
TANK FOR OFFICE/HOTEL/RESIDENTIAL LOBBIES WITH
7.6M WIDE

PLAZA SPACE AND OFFICE, HOTEL (100 ROOMS) AND


RAMP UP GR

RESIDENTIAL FLATS (268 UNITS) WITH SKY TERRACES,


COMMERCIAL
2 - WAY DR

UP LIFT LOBBY 02 COMMUNAL/ANCILLARY FACILITIES AND 4 BASEMENT


ADIENT 1 :12

UP ST 11
CONSISTING AN UNDERGROUND PEDESTRIAN LINK
IVEWAY

(UPL) AND BASEMENT CARPARK ON LOTS 00144C(PT)


MDF ROOM & 00147V TS 30 AT 8 SHENTON WAY (DOWNTOWN
SSL 03D CORE PLANNING AREA)

6000
6000 DRAWING DESCRIPTION

K RESTAURANT 06 UST 01

UESC 01

UESC 02
RETAIL SERVICE CORRIDOR

3000

L UPL LIFT

PROPOSED ROAD RESERVE LINE


RA 3000
GR

MP LOBBY 01
(BASEMENT 1)
AD

UP
IE
NT
1:
15

SHOP 05 RESTAURANT 07 2110

MECHANICAL & ELECTRICAL ENGINEER


SSL 08 ST 08
COMMON ENERGY
TRANSFER STATION (ETS)
3000

1800

Meinhardt (Singapore) Pte Ltd


UP 168 Jalan Bukit Merah, #09-01, Surbana One

UESC 03

UESC 04
M.1 UP
SINGAPORE 150168
UST 02
TEL: +65 6273 5255 FAX: +65 6274 0788
RETAIL BOH
RETAIL BOH

SCALE
BY DATE

DRAWN Hoang OCT 2021

DESIGNED ESC OCT 2021


BOUNDARY LINE / ROAD RESERVE LINE 3500

CHECKED ESC OCT 2021

ESCALATORS AND STAIRCASE TO


APPROVED RS OCT 2021

JOB NO. DISCIPLINE DRAWING NO. REVISION

EE OF-500-001 -