S.No. Item Description Unit Total QTY Rate (Rs.) Amount Remarks on 25th Sept 2023
1.00 CIVIL WORKS
1.01 Providing and fixing deck slab (without reinforcement and RMC ) as per approved structural drawings. The sheet
should be glavanised, high tensile structural grade steel 240 mps with a coating mass upto of 120, thickness 1 mm
as and Galvanisd steel as per IS 277 for verious areas (including DG Shade). Sqm 750 405 303,750.00 The value to be reworked
1.02 Providing and laying Steel reinforcement work for RCC including straightening, cutting, bending, placing in position
and binding all complete. Thermo mechanically Treated bars of grade Fe 500D or more.For DG foundation/ HVAC
outdoor Foundation/ deck slab etc. MT 6
1.03 WATERPROOFING
Providing, applying & testing water proofing treatment of RCC sunken slabs (toilets etc) comprising of the following
operations.
Cleaning RCC surfaces and plastering of RCC and brick wall surface with 12mm cement mortar 1:4 (1cement : 4
coarse sand) mixed with CICO admixture as per manufacturer's specifications.
Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/Sqm, the second & third layer to be @
0.126kg/Sqm ) each admixed with grey cement over a coat of neat cement slurry admixed with chemical CH - 9
and sealing all corners, joints, junctions.
12mm thick protective plaster 1:4 (1 cement : 4 coarse sand) over treated surface etc complete. (Quoted rate to Sqm 190 5500 1,045,000.00
include grouting of RCC surface for any cracks/ fissures)
This treatment shall be upto 300mm height on all walls from finished floor level, all around water proof area. All
debris to be disposed at designated area by authorities.
Special warranty for 10 yrs to be out lined along with autorized specialized applicator executing the job. Pond
testing for 4 days.
1.04 Dismantling marble,granite, ceramic tile or other flooring with mortar upto existing concrete slab in the various
areas and dismantling marble,granite, ceramic tile skirting, ceramic tile /granite slab wall dado etc.with mortar
backing including cleaning of existing cement plastered surface and concrete surface in a manner which facilitate
laying of new flooring /plastering/ wall dado / tile clading without undue extra expense. The rate shall include Sqm 400
removal of debris from site including costs of all materials,equipments, labour charges, curing, cleaning etc.
Complete
1.06 Supplying and Filling in plinth with river sand and under floors including, watering, ramming consolidating and
dressing complete Cum 20 4750 95,000.00 The value to be reworked
1.07 Removal of existing windows with grills from external domes (shifting to outside on ground floor and to be collected No. 45 2200 99,000.00 Existing rates to apply
by TTD)
1.08 Removal of existing doors with frames from external domes (shifting to outside on ground floor and to be collected No. 40 2200 88,000.00 Existing rates to apply
by TTD)
Rebarring: Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY-200-R or equivalent
chemical with the help of Hilti HIT-MD 2000/5000 dispenser or equivalent, into a hole of dia & depth as per
manufacturer/structural consultant's specification and fixing rebars of the required diameter subsequently. The
chemical should have successful usage in dry and wet areas. The chemical should be suitable for both cracked
1.09 and non cracked concrete. Fixing methodology to be followed as per manufacturers guidelines. - Steel will be
paid under separate subhead. Manufacturer to submit Rebar Depth Calculation based on design loads & other
parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed
rebar connections” for approval.
2.1
Providing and laying about 8mm. thick 1st. Quality vitrified tiles of as approved by Architect, tiles of
size 600x1200 mm in dado/Floor on 12mm thick cement mortar 1:4 (1 cement : 4 coarse sand/stone Brands approved by Architect and
Sqm 390 2363 921,570.00
dust) joined with Cementious grout of matching colour, cured, cleaned complete in all respects.(Basic TCS. Rates to be reviewed.
cost Rs.950/-per sqm.)
2.2
Providing and laying about 10mm thick 1st. Quality vitrified tiles of as approved by Architect, tiles of
size 600x600 mm in Floor on 12mm thick cement mortar 1:4 (1 cement : 4 coarse sand/stone dust) Brands approved by Architect and
Sqm 175 1878 328,650.00
joined with Cementious grout of matching colour, cured, cleaned complete in all respects.(Basic cost TCS. Rates to be reviewed.
Rs.600/-per sqm.)
2.3
Providing and laying about 8mm. thick 1st. Quality vitrified tiles of as approved by Architect, tiles size
approved by Architect in dado on 12mm thick cement mortar 1:4 (1 cement : 4 coarse sand/stone dust) Brands approved by Architect and
Sqm 110 3887 427,570.00
joined with Cementious grout of matching colour, cured, cleaned complete in all respects.(Basic cost TCS. Rates to be reviewed.
Rs.2000/-per sqm.)
2.4 Providing and laying about 10mm-12mm. thick 1st. Quality vitrified tiles of as approved by Architect,
tiles of size 1200 mm x 1200 mm in admin office First Floor on existing floor with chemical joined with Brands approved by Architect and
Sqm 350 3260 1,141,000.00
Cementious grout of matching colour, cured, cleaned complete in all respects.(Basic cost Rs.1400/-per TCS. Rates to be reviewed.
sqm.)
2.5 Providing and laying pre polished Granite Stone on the staircase, jambs, ledge walls and lift entrance
facia in required design and patterns, making cutouts, holes and half/ full moulding all complete as per
the architectural drawings with 18-20 mm thick stone slab over 12 mm (average) thick base of cement
mortar 1:3 (1 cement 3 coarse sand) laid and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete Granite thickness availavbe on local
Sqm 140 8500 1,190,000.00
as specified and as directed by the Engineer-in-Charge. Basic cost of Granite Rs. 2000/- sqm. market.
3.00 PARTITION
3.01 Providing & Fixing T Line Cubicle System in SS-304 MEDIUM Series of size Width 900mm x Depth
1200mm x 2400mm, Door Size - 900mm x 2100mm, Divider Height - 1830mm, Comprising of Rigid SS
components: (1) SS304 Indicator Lock(2) SS304 Automatic Reverse Hinges (3) SS304 Height Adjustable
Legs(4) SS304 Door Knob(5) SS304 Coat Hook & Aluminum (Brush Finish): (6) Top Rail (7) h Section
No. 23 47000 1,081,000.00 Merino ZMS Series
(8) U Section (9) Silicon Strip to be inserted in h Section to provide Noise Dampening(10) Screws &
Plugs with (11) Water, Chemical, Heat, bacteria, Fire, Impact & Scratch Resistant 12 mm T Line High
Pressure Compact Laminate. The 12mm HPL to have a minimum density of 1350 kg/m3 with a
warpage limit of .5% of its length. The Top Rail will be fixed end to end and all the mid and end
pilasters will get fixed into it. The whole system will have Upto 150 mm clearance height to the floor. U
Sub Total 3.00 1,081,000.00
ii) Rockwool insulation (Min. 2Hrs Fire rated ), 50 mm thk Sqm 135 850 114,750.00
iii) 12mm MR gypsum on Ceilling with GI frame Sqm 135 700 94,500.00 Area is less.
5.02 Providing and fixing false ceiling at all heights with integral densified calcium silicate filler false ceiling
tiles of Size 595x595mm/1195mmx595mm of approved texture, design and patterns having true
horizontal level suspended on inter locking metal T-Grid of hot dipped galvanised iron section of
0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of
size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary
intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm,
Sqm 400 2430 972,000.00 Armstrong make is considered
suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm
long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm
length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size
24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl
plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out
as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular
edged light weight calcium silicate false ceiling tiles.
. Sub Total 5.00 1,269,000.00
6.00 WALKWAYS
6.01 Providing & Fixing shade fabricated MS hollow Pipe, Insert plates made out of MS MT 6 150000 900,000.00
plates/Chanels/Angles I/C steel lugs, fastner as per approved shop drawings and grout in RCC Slab
including cost of all consumables (all chemicals from HILTI) etc with Metal coat finish (multipurpose PU
finish) including primer (epoxy zinc phosphate primer) in an approved shade by the Architect. The work
includes carefully dismantling of the existing brickbat coba till mother slab, cleaning, and pouring the
concrete to match the floor finish after fixing of MS Structure. Checkered plates may be required in few
areas. All debris to be disposed at designated area by authorities. A 12mm high railing on both sides
6.02 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of Sqm 55 3850 211,750.00
approved size and as per approved pattern on MS Frame work of walkways (MS framework already The value to be reworked
included in item 15.01) All debris to be disposed at designated area by authorities.
6.03 Providing and fixing Stainless Steel Railing . Providing and fixing of 304 grade stainless steel railing
(PVD finish - shade as approved by Architect) on stairs (folding/conventional) to required design and
pattern ( as per drawings ) with the following technical specifications. Top rail/ runner shall be of 50mm
Ø-16 G stainless steel pipe. Three no. horizontal runner shall be of 16mmdia-18G stainless steel Rmt 120 9774 1,172,880.00
pipe.Vertical posts/Balusters shall be of 40mm dia-16G Stainless steel pipe at an average distance of
2'8''. All other fittings shall be of standard quality asper direction of engineer in charge., including
necessary welding grouting in cement mortar etc. complete as per design and drawing.
6.04 Providing and fixing Stainless Steel Railing . Providing and fixing of 304 grade stainless steel railing
(PVD finish - shade as approved by Architect) on stairs (folding/conventional) to required design and
The value to be reworked
pattern ( as per drawings ) with the following technical specifications. Top rail/ runner shall be of 50mm Rmt 120 8068 968,160.00
considering on the wall
Ø-16 G stainless steel pipe. All other fittings shall be of standard quality asper direction of engineer in
charge., including necessary welding grouting in cement mortar etc. complete as per design and
drawing.
. Sub Total 6.00 3,252,790.00
7.1 Providing and applying the APEX weather proof exterior emulsion (water based 100% acrylic) or
approved equivalent grade paint to all type of cement plasters, concrete, exterior ceiling etc. or surface /
sub straits (which are subjected to continuous seepage and dampness. The surface to be painted shall
be made free from any loose paint, dust, grease and any fungus, algae or moss, on it shall got be
removed thoroughly by vigorous wire brushing and cleaning with water. Then one coat of exterior grade
wall primer be applied after which any surface imperfection such as holes, dents, fine cracks shall be
corrected by filling with external wall putty. Thereafter three coat of exterior grade wall primer and again Sqm 4120 260.00 1,071,200.00
surface imperfection to be corrected. Thereafter Apex weatherproof exterior emulsion paint to be applied
in two coats. The color and pattern/ color combination of the paint shall be got approved from Engineer
in charge. The stock of the quantity for all material as manufacturer’s theoretical consumption (per unit
of actual wall surface area) shall be made available at site before commencement of the painting work.
The rate includes cost of all materials, labour, scaffolding, ladders charges, storing&safeguarding the
labour in all heights (all external walls, compound walls etc.) Contractor has to take all risk insurance
7.4
Mode of measurment - Below
Application of 2 layers of water based metallic gold highlighter as existing finish paint on the edges and 300mm width we are consider in
Sqm 500 1,200.00 600,000.00
terminations as exiting pattern RMT and rate as same Sqmt
apply.
1 WC and accessories
1.1 Water Closet Providing and fixing vitreous wall hung china water
closet (European type W.C.pan) complete with
proprietry seat and cover (soft close), pan
connector, suitable mounting brackets/chair
including cutting and making good the walls and
floors wherever required with inbuilt cistern tank
1.2 Indian Pan (WC) Providing and fixing vitreous china WC squatting
pan (Indian Type W.C. pan) with 100mm dia sand
cast iron P or S-trap 32mm dia G.I. flush pipe with
fittings and clamps and 32mm dia brass unions,
20mm dia G.I. overflow pipe with specials and
mosquito proof coupling or approved municipal
design i/c painting of C.I./M.S. brackets, fittings i/c
cutting & making good the walls and floors.
1.3 Indian Pan Cistern Providing and fixing cisterm for the item at Sr no
1.2 with fittings, clamps and other accessories
1.4 Health faucet Providing and fixing hand held ablution fitting
(health faucet) with one metre long flexible tube
and wall hook, all complete of following make.(or
equal approved)
1.5 Toilet paper holder Providing and fixing stainless steel finish toilet
paper holder including cutting and making good
the walls complete of following make and type: (or
equal approved)
2.2 Wash basin (FOR HANDICAPP TOILET) Providing and fixing vitreous china wash basin with
special C.I brackets, including C.P. brass waste of
standard pattern, 32 mm C.P brass bottle trap,
complete including cutting and making good the
walls and floors, wherever required of the
following make and type: (or equal approved)
2.3 Faucet Providing and fixing of the bib cock with wall flange
of following make. (or equal approved)
2.4 Brass Bib Cock Providing and fixing of the brass bib cock
with wall
2.5 Faucet 2 (basin mounted) Providing, fixing, testing and commissioning mixer
with suitable extension peice for wash basin
solenoid valve of approved make cold water mixer
counter mounted unit, solenoid valve including
cutting and making good the walls and floors as
required, all complete
2.6 Sensor Urinal with Assembly kit Providing, installing and commissioning INFRA-RED
dual controlled electrically operated (220V, AC
mains) and battery operated automatic urinal
flushing system, including cutting and making good
the walls complete with all necessary fittings to
make it operational as required
2.7 Urinal partition WALL HUNG URINAL DIVISION in HPL
2.8 Bottle trap Providing and fixing 32 mm C.P brass bottle trap,
complete including cutting and making good the
walls and floors, wherever required
3 Common fixtures
3.1 Angle valve Providing and fixing of 15 mm dia brass angle valve
(inlet fitting ball valve type) having strainer screen
complete with wall flange
3.2 Floor Trap/Floor drain Cockroach Trap Stainless Steel AISI 304 (18/8) Anti-
Cockroach Floor Drain Cover/Jali/Grating/Nahani
Trap. Drain Pipe Size 100mm/4", Overall Size
127mm/5". Round Frame Glossy Finish
3.5 Tissue Paper Dispenser Providing and fixing stainless steel finish towel
dispensor including cutting and making good the
walls complete
3.6 Soap Dispenser Providing and fixing automatic liquid soap
dispenser including cutting and making good the
walls complete
5 SINKS
5.1 Office Pantry Sink Providing and fixing Stainless Steel sink
WITH SINGLE bowl (approx size -585 x
480 x 200 mm and thickness- 1.2 mm)
approx. (Square designer satin finish) in
the pantry platform as under counter type
in the slab neatly according to the size of
sink, complete as directed. The item
includes waste coupling, stainer, drain drop
connection to the floor trap, waste pipe
including cost of all material, labour
charges, curing etc. complete as directed
with basin mounted mixture
5.2 Conservation Wash Area Providing and fixing Stainless Steel sink
WITH SINGLE bowl (approx size -1350 x
500 x 200 mm and thickness- 1.2 mm)
approx. (Square designer satin finish) in
the pantry platform as under counter type
in the slab neatly according to the size of
sink, complete as directed. The item
includes waste coupling, stainer, drain drop
connection to the floor trap, waste pipe
including cost of all material, labour
charges, curing etc. complete as directed
with flexible turning basin mounted mixture
SRI VENKATESWARA MUSEUM
SUBHEAD : PLUMBING INSTALLATIONS
Units Ground Floor First Floor Total IMAGES
Nos
10 9 19
Nos
6 1 7
Nos
6 1 7
Nos
16 10 27
Nos
10 9 19
Sqm
15 13 28
Nos
1 1 2
Nos
19 9 28
Nos
6 1 9
Nos
1 1 2
Nos
8 4 12
Nos
6 2 8
Nos
20 10 30
Nos
54 38 92
Nos
40 36 76
Nos
1 1 2
Nos
13 8 21
Nos
13 8 21
Nos
15 8 23
Nos
1 1 2
Nos
1 1 2
Nos
1 1 2
Nos
0 1 1
Nos
0 1 1
Total
Rate Total
36107 686033
12800 89600
4800 33600
2800 75600
2560 48640
16500 462000
14500 29000
6800 190400
2800 25200
6930 13860
28500 342000
9500 76000
2890 86700
2460 226320
1460 110960
750 1500
16200 340200
5100 107100
2100 48300
2100 4200
4260 8520
9340 18680
12500 12500
16980 16980
3053893
Jaquar Make ONS-WHT-10853S300UFSM Rimless
Single Piece WC with UF Soft Close Slim Seat Cover,
Hinges, Dual Flush Cistern Fitting, Fixing Accessories
And Accessories Set, Size: 385x720x710 mm, S Trap-
300 mm
SSCT-RG-127-ROUND
2.1 Providing, jointing and fixing UPVC Soil, Waste and Vent System
The work shall be done as per technical specifications and in general shall
include:
Material: UPVC pipes and fittings (moulded as well as fabricated) conforming to IS : 13592 -
Type B
Fittings shall include all standard moulded as well as fabricated fittings like
bends, tees, Y-tees, crosses, boss connections, access pieces, saddle
pieces, cleanouts, adaptors for connections to other materials, plugs,
reducers, cowls, offsets and other specials
Jointing: Pushfit rubber ring jointing technique in general. Solvent cement joints may be
provided for fittings and specials which are not manufactured with pushfit rubber joints
Installation, Testing and Commissioning: The installation shall be complete in all respects
including cutting chases / holes in walls, slabs, excavation, refilling and disposal of surplus
earth where required and making good, etc
M.S Supports: All vertical and suspended horizontal pipework shall be fixed on MS brackets
and hangers with U-clamps made from 10 mm dia galvanised steel rod complete with nuts
and washers. Cost for MS structural work for supports shall be included in the rates
Conctere Encasing ( In case of Sunken Floor/ burried pipes): The pipes and
fittings shall be encased with 75 mm thick cement concrete ( 1:2:4) all around
Making Good the Structure Crossongs: For all horozontal and vertical crossings of building
structure (slabs, walls, beams, coloumn etc), the space between pipe and the structure shall
be made good and water tight with concrete. The annular space between the pipe and the
sleeves shall be sealed (upto a minimum depth 25 mm) with fire resistant acrylic based
sealent of approved make and quality.
a) 75 mm OD M
b) 110 mm OD M
c) 160 mm OD M
2.2 Providing & fixing UPVC soil, waste, vent pipework comprising UPVC pipe conforming
to IS :4985-1983 and of required class as specified below and fittings (moulded as well as
fabricated) like elbows, bends, reducers, threaded tail pieces, caps and and other specials.
jointing with cement solvent, chasing, cutting and making good the walls, complete in all
respects including testing of complete installation.
2.3 Providing and fixing of UPVC Floor Traps formed out of bore 'P' trap with 50 mm water
seal, setting in 1:2:4 mix cement concrete block or clamping to the wall or suspending with
the ceiling including cutting and making good the walls and floors wherever required.
2.4 Providing and fixing PVC floor trap EXTENTION PIECE formed out of 110
mm pipe with multiple side inlets formed with saddle pieces, suitable for 40,
No.
50 and 63 mm dia side connections as per standard detail.
2.5 Providing and fixing floor drain points formed out of 63x 50 mm dia UPVC elbow with
suitable extension piece, fitted with 75 mm dia nickel bronze grating and frame, embedded No.
in floor, all complete.
2.6 Providing and fixing screwed down type nickel bronze alloy cast floor cleanout with
opening arrangements for soil / waste pipe and other necessary fittings inlcuding jointing, all
complete as per standard detail.
2.8 Making connection with existing UPVC/CI Soil and Waste pipework ( upto sizes 160
mm dia). The work includes loosening / removing the existing lead joints, rotating the
direction of the existing tees, bends etc. so as to connect with new branch lines from the
toilets, redoing the joints with 'solvent joint', testing, commissioning all complete. Any pipe No.
piece, fittings etc. required to make the connection shall be measured in Item No. 2.1
TOTAL FOR "Soil, Waste & Vent Pipework" carried over to SUMMARY
3.1 Providing and fixing in position CPVC pipes conforming to IS: 15778:2007 (Grade
SDR-11) with all fittings, brass threaded adaptors and specials, solvent cement/threaded
jointing, effecting proper connections, cutting chases in walls and floors and making good
(including making connection with existing pipework), Note: Pipe work in shafts, ceiling
voids and terrace shall be supported/ fixed on MS structural supports with U-clamps
complete with nuts and washers.Cost for MS structural work for supports shall be included
in the rates all complete. ( Pipework inside the toilets and pantry etc)
Note :
1) Solvent Cement shall be of make and grade as specified by the manufacturer of CPVC
piping system.
2) The entire CPVC piping system shall be installed, tested and commissioned following the
recommendation of the manufacturer.
3.2 Providing and fixing of nickel plated brass/ nonferrous alloy fullyway ball valve
( minimum working pressure of 20 bar ) with operating handle of approved make.( Note:
Existing isolating valve shall be used for making connection with new pipework)
a) 15 mm dia No.
b) 20 mm dia No.
c) 25 mm dia No.
d) 32 mm dia No.
e) 40 mm dia No.
f) 50 mm dia No.
3.3 Providing and fixing flanged end Wafer type check valve (non return valve) of
Class PN 10, having stainless steel body and disc, trim and spring of approved make,
including a set of MS flanges, required nos. of nut & bolts all complete.(extra for sump
pumps riser line)
a) 32 mm dia No.
b) 50 mm dia No.
3.4 Providing and fixing Cast Iron butterfly valve as per IS: 13095 of Class PN 16, having
epoxy coated disc, carbon steel shaft, EPDM rubber body liner and of approved make.
including a set of MS flanges, required nos. of nut & bolts all complete.
a) 15 mm dia No.
b) 20 mm dia No.
c) 25 mm dia No.
d) 32 mm dia No.
e) 40 mm dia No.
f) 50 mm dia No.
Total of 2 and 3
RA MUSEUM
STALLATIONS
85 85 650.00 55,250.00
55 55 720.00 39,600.00
27 27 2500.00 67,500.00
27 27 750.00 20,250.00
18 18 750.00 13,500.00
16 16 1250.00 20,000.00
Rate only Rate only 1450.00
25 25 1850.00 46,250.00
Rs. 1,498,600.00
90 90 780 70,200.00
310 310 850 263,500.00
2 2 2250.00 4,500.00
15 15 2650.00 39,750.00
9 9 3200.00 28,800.00
15 15 3500.00 52,500.00
1 1 3850.00 3,850.00
0 0 4500.00 -
2 2 4850.00 9,700.00
2 2 1850.00 3,700.00
7 7 1850.00 12,950.00
7 7 1850.00 12,950.00
6 6 1850.00 11,100.00
0 0 1850.00 -
0 0 1850.00 -
Rs. 1,585,700.00
3,084,300.00
SRI VENKATESWARA MUSEUM
SUBHEAD : SEWERAGE MANHOLE & CLEANING EXISTING EXTERNAL SEWER AND SUPPLY L
1.1 Constructing brick masonry Rain Water Collection Rate Only No.
Chamber 50x45x60 cm with 75 class designnation
F.P.S. brick work in cement mortar 1:5 ( 1 cement : 5
coarse sand ) including 500x450 mm S.F.R.C. (Steel
Fibre Reinforced Concrete) horizontal grating with frame
complete as per standard design/ drawing.
0.91 m deep with Heavy Duty FRP cover and frame, Rate Only No.
560 mm internal diameter fixed in cement concrete
1:2:4 (1 cement : 2 coarse : 4 graded stone aggregate
20 mm nominal size) including centering shuttering all
complete.
1.5 Extra for depth for RWCC size
1.66 m deep with Heavy Duty FRP cover and frame, Rate Only No.
560 mm internal diameter fixed in cement concrete
1:2:4 (1 cement : 2 coarse : 4 graded stone aggregate
20 mm nominal size) including centering shuttering all
1.10 complete.
Cleaning existing external sewer lines all complete 1 Job
including required chemical for cleaning.
TOTAL
MUSEUM
L SEWER AND SUPPLY LINES
22500.00
8500.00 102000
26500.00 159000
28500.00
38100.00
4200.00
5300.00 2650
7500.00
8700.00
42600.00
150000 150000
Ro as actual
150000 150000
Ro as actual
Rs. 563650
ITEMS MAKES
5 PLY/MDF/HDF Century/Greenply/Duro
6 Adhesives Fevicol/Pidilite/Sika
10 Cubicles Merino/Century/Greenlam