Professional Documents
Culture Documents
Complete Elevator System MRL Certificate
Complete Elevator System MRL Certificate
COMPANY TITLE
H.K.S HAS ASANSÖR KAUÇUK PLASTİK METAL SAN. VE TİC. A. Ş.
COMPANY ADRESS
KALE MAH. ANKARA CAD. 13. KM NO:77– KESTEL, BURSA TURKEY
FILE NR.
LD.IV.0034
PRODUCT DESCRIPTION
2:1 SUPENSION ELECTRICAL LIFT-WITH MACHINE ROOM,MACHINE
ROOMLESS
PRODUCT TYPE/TYPES
ELECTRICAL LIFT INTENDED USED FOR PERSON AND GOODS
COMFORMITY ASSESMENT DATE
13.10.2020
RELEVANT STANDARDS USED FOR CONFORMITY ASSESMENT
EN 81-20 :2020
EN 81-50 :2020
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 1/13
REPORT OF EU TYPE EXAMINATION
The Lift Directive (2014/33 / EU) published in the Official Gazette dated 29 June 2016 and numbered 29757, within the
framework of Section 4, Article 19 (a) of the 2014/33 / EU Lift Directive IV. For the purpose of issuing an EU Type
Examination certificate in accordance with subparagraph b of the Annex, the inspection and test procedures of the
applicant's Electric Lift were carried out in accordance with the 2014/33 / EU Lift Directive Annex-I Basic Health and
Safety Rules and TS EN 81-20 and TS EN 81-50 standards.
GENERAL INFORMATIONS
COMPANY INFORMATIONS
COMPANY NAME H.K.S HAS ASANSÖR KAUÇUK PLASTİK METAL SAN. VE TİC. A. Ş.
2.4. TYPE VARIENTS: HAS 225 MRL, HAS 320 MRL, HAS 375 MRL, HAS 450 MRL, HAS 630 MRL, HAS 800 MRL,
HAS 1000 MRL, HAS 1200 MRL, HAS 1275 MRL, HAS 1600 MRL, HAS 2000 MRL, HAS 2250 MRL, HAS 2500 MRL, HAS 2750
MRL, HAS 3000 MRL
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 2/13
REPORT OF EU TYPE EXAMINATION
Rated Load kg 225 320 375 450 630 800 1000 1200 1275 1600 2000 2250 2500 2750 3000
Number of
3 4 5 6 8 10 13 16 17 20 26 30 33 36 40
persons
Rated speed m/s 0,50 m/s, 1,00 m/s, 1,20 m/s, 1,60 m/s, 2,00 m/s, 2,25 m/s, 2,50 m/s
Car area (Min- 0,60- 0,79- 0,98- 1,17- 1,45- 1,73- 2,15- 2,57- 2,71- 3,13- 3,82- 4,28- 4,62- 5,43- 5,43-
Max) 0,70 0,90 1,10 1,30 1,66 1,90 2,40 2,80 2,95 3,56 4,20 4,40 5,00 5,48 5,80
m2
Type of Door Central and telescobic landing doors
Number of Entry Single entry or 180° double entries
Max. Number of
Stops/ Max. 41
Number of Flats
Max. Travel
121
Distance m
Min. top floor
3200 (It varies according to the declared speed and capacity.)
height mm
Min. pit depth mm 1000 (It varies according to the declared speed and capacity.)
Type of Car guide 70x65x9 mm, 75x62x10 mm, 89x62x16 mm, 90x75x16 mm, 125x82x16 mm, 127x89x16 mm,
rails mm 140x108x19 mm, 140x102x 28,6 mm, 140x127x31,75 mm
The model lift examined in the field also meets the requirements of the standards stated below. The type model lifts
specified in this report will be installed by Has Asansör in accordance with the following standards.
2.7. INTENDED USE OF THE PRODUCT: Public buildings, residences, business centers, hospitals and state buildings
2.8. MACHINERY SPACES: Inside the well or in a machinery room if the conditions of the room meets the requirements of
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 3/13
REPORT OF EU TYPE EXAMINATION
2.9. FEATURES OF THE WELL: Concrete Wall Construction Well, Steel Construction Well.
2.10. INSPECTION AND MAINTENANCE CONDITIONS : Ordinary inspection and maintenance activities shall be performed
from machinery spaces where machinery is located in a machinery room. If the machinery is located inside the well
maintenance activities shall be performed from the top of the car and car is blocked by blocking devices which is connect to
the guide rails.
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 4/13
REPORT OF EU TYPE EXAMINATION
TECNOLAMA
CDL O4/09-009/PR/R BUREAU VERITAS (1035)
(Fermator)
STROJIRENSKY ZKUSEBNI
CANLİFT CL SG-P I-61-00691/19/ZZ
USTAV (1015)
ALY-01 874K/TE/11.10.2017
ALY-03 938/TE/20.02.2018
LIFT Certificat TU Sofia-
ALY-04 939/TE/31.07.2018
Technical University of Sofia-
AKSÖZ MAKİNA ALY-05 940/TE/11.07.2018 Technologies Ltd (2201)
SZUTEST (2195)
ALY02 2195-LD-2310905
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 5/13
REPORT OF EU TYPE EXAMINATION
3.2.5. BUFFERS
3.2.5.1. ENERGY ACCUMULATION BUFFERS:
MANUFACTURER TYPE TYPE CERTIFICATE NR. NOTIFIED BODY
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 6/13
REPORT OF EU TYPE EXAMINATION
ARCODE NL 13-400-1002-048-11
ARKEL ARL 700 NL 17-400-1002-048-15 LIFTINSTITUUT(0400)
ARCUBE NL 19-400-1002-048-19
ML 4O P Ver-2.0 NL 16-400-1002-064-09
ML 50 S NL 16-400-1002-064-10
MİKROLİFT ML COMBO 40 NL 19-400-1002-064-13 LIFTINSTITUUT(0400)
ML COMBO 50 NL 19-400-1002-064-14
ML COMBO-X NL21-400-1002-064-15
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 7/13
REPORT OF EU TYPE EXAMINATION
BFK464-17R EU BD-1051
BFK464-18R EU BD-1056
BFK464-20R EU BD-1034
INTORQ TÜV SÜD (0036)
BFK464-22R EU BD-1054
BFK464-25R EU BD-1053
BFK464-28R EU BD-1052
EVO-01 CM/061/13
EVO-02 CM/062/13
ALZOLA TÜV REHINLAND(1027)
EVO-03 CM/063/13
EVO-04 CM/064/13
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 8/13
REPORT OF EU TYPE EXAMINATION
BFK464-17R EU BD-1051
BFK464-18R EU BD-1056
BFK464-20R EU BD-1034
INTORQ TÜV SÜD (0036)
BFK464-22R EU BD-1054
BFK464-25R EU BD-1053
BFK464-28R EU BD-1052
EVO-01 CM/061/13
EVO-02 CM/062/13
ALZOLA TÜV REHINLAND(1027)
EVO-03 CM/063/13
EVO-04 CM/064/13
CONFORMITY
MANUFACTURER TYPE
REPORT/CERTIFICATE NUMBER
HAS ASANSÖR
FAXİ --
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 9/13
REPORT OF EU TYPE EXAMINATION
GLS 20 ----
GLS 26
GEM GLS 34
GLS 40
GLS 48
CONFORMITY
MANUFACTURER TYPE
REPORT/CERTIFICATE NUMBER
SAVERA T50 – T70 – T75 - T89 – T90 – T125 – T127 – T140 --
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 10/13
REPORT OF EU TYPE EXAMINATION
CONFORMITY
MANUFACTURER TYPE
REPORT/CERTIFICATE NUMBER
MULTILIFT (MP Wire Ropes s.r.l.) 6,5 MM (8x19W – IWRC) 1770 N/mm2 --
CONFORMITY REPORT/CERTIFICATE
MANUFACTURER TYPE
NUMBER
ARCODE NL 13-400-1002-048-11
ARKEL ARL 700 NL 17-400-1002-048-15
ARCUBE NL 19-400-1002-048-19
ML 4O P Ver-2.0 NL 16-400-1002-064-09
ML 50 S NL 16-400-1002-064-10
MİKROLİFT ML COMBO 40 NL 19-400-1002-064-13
ML COMBO 50 NL 19-400-1002-064-14
ML COMBO-X NL21-400-1002-064-15
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 11/13
REPORT OF EU TYPE EXAMINATION
3.5. EVALUATION:
The evaluation activity was carried out by examining the technical files submitted by the applicant and performing the
inspection and test procedures of the model elevator assembled. The evaluation was carried out at the applicant's facilities,
in the installed elevator site and by the technical expert from D KARE head office with the participation of the applicant
representative Şamil ÇAHAL.
Assesment findings are listed on the file FR.LD.04EK1 EU Type Examination finding report which is annex of this report.
Recommendation Of The Technical Expert: According to the conformity assessment activities the model lift which is installed
in the address stated above meets the essential requirements of annex I of 2014/33/EU Lift Directive. This report is related to
the lifts and inspection of lifts those are stated on this report.
Note (Rev 01): The report was revised on 09.03.2021 due to the missing components in the variant declaration form
declared by the customer in the report.
Note (Rev 02): The report was revised on 01.10.2021 due to the missing components in the variant declaration form
declared by the customer in the report.
Note (Rev 03): The report was revised on 18.10.2021 due to the missing components in the variant declaration form
declared by the customer in the report.
Note (Rev 04): The report was revised on 26.11.2021 due to the missing components in the variant declaration form
declared by the customer in the report.
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 12/13
REPORT OF EU TYPE EXAMINATION
Report Annexes : --
Report Date: 27.11.2020
REPORT INFORMATIONS
Prepared by,
Signature
Technical Expert
Mustafa GÖRMÜŞ
Document Nr: FR.LD.04 Issue Date: 07.02.2019 Rev. Nr: 05 Rev. Date: 20.07.2022
This assessment report could not be copied and distributed partly without approval of D KARE Page : 13/13