User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.596
Rev.A.1808
MODEL 53515/53615/63515/63615/73515/73615
Before the valve put into use, please fill in the below content so as to
help us to refer in the future.
Parameter Set
Factory
Parameter Unit Actual Value
Default
Time of Day h:m Random
Control Mode A-01/02/03/04 (Only
suited for 63615/73615),53515 only / A-01
have A-01/02
Water Treatment Capacity(Meter 3
m 200.0
type)
Service Days(Time clock type, by
D. 03
days)
Regeneration Time h:m 02:00
Catalogue
Notice
1. Product Overview ................................................................................... 3
1.1. Main Application &Applicability .................................................... 3
1.2. Product Characteristics ................................................................ 3
1.3. Service Condition ......................................................................... 6
1.4. Product Structure and Technical Parameters .............................. 7
1.5. Installation .................................................................................. 10
2. Basic Setting & Usage ......................................................................... 14
2.1. The Function of PC Board ......................................................... 15
2.2. Basic Setting & Usage ............................................................... 16
3. Applications .......................................................................................... 20
3.1. Flow Chart .................................................................................. 20
3.2. The Function and Connection of PC Board ............................... 22
A. Signal Output Connector .............................................................. 24
B. Interlock ........................................................................................ 28
C. Pressure Relief Output ................................................................. 28
D. Remote Handling Connector ........................................................ 29
E. Interlock System ........................................................................... 29
F. Series System ............................................................................... 30
3.3. System Configuration and Flow Rate Curve ............................. 30
3.4. Parameter Settlement ................................................................ 33
3.5. Parameter Enquiry and Setting.................................................. 35
3.6. Trial Running .............................................................................. 40
3.7. Trouble-Shooting........................................................................ 41
3.8. Assembly & Parts ....................................................................... 46
4. Warranty Card ...................................................................................... 55
I
MODEL 53515/53615/63515/63615/73515/73615
Notice
To ensure normal operation of the valve, please consult with
professional installation or repairing personnel before use it.
If there are any of pipeline engineering and electric works, there must
be finished by professional at the time of installation.
Do not use the control valve with the water that is unsafe or unknown
quality.
Depending on the changing of working environment and water
requirement, each parameter of softener should be adjusted accordingly.
When the water treatment capacity is too low, please check the resin.
If the reason is shortage of resin, please add; if the resin is turn to
reddish brown or broken, please replace.
Test water periodically to verify that system is performing satisfactorily.
Ensure that there is solid salt all the time in the brine tank in the course
of using, when this valve is used for softening. The brine tank should be
added the crystalline coarse salt only, at least 99.5% pure, forbidding
use the small salt.
Do not put the valve near the hot resource, high humidity, corrosive,
intense magnetic field or intense librations environment. And do not
leave it outside.
Forbidden to carry the injector body. Avoid using injector body as
support to carry the system.
Forbidden to use the brine tube or other connectors as support to carry
the system.
Please use this product under the water temperature between 5~50 ℃,
water pressure 0.2~0.6MPa. Failure to use this product is under such
conditions voids the warranty.
If the water pressure exceeds 0.6MPa, a pressure reducing valve must
be installed before the water inlet. While, if the water pressure is under
1
MODEL 53515/53615/63515/63615/73515/73615
2
MODEL 53515/53615/63515/63615/73515/73615
1. Product Overview
3
MODEL 53515/53615/63515/63615/73515/73615
If outage overrides 3 days, the time of day indicator “12:12” will flash
to remind people to reset new time of day. The other set parameters do
not need to reset. The process will continue to work after power on.
LED dynamic screen display
The stripes on dynamic screen flash, they indicate the control valve
is in service; otherwise, it is in regeneration cycle.
Buttons lock
No operations to buttons on the controller within 1 minute, button
lock indicator lights on which represents buttons are locked. Before
operation, press and hold the and buttons for 5 seconds to unlock.
This function can avoid incorrect operation.
It can choose all models by program selection
When all symbols light on, press and hold “ ” and “ ” buttons
more than 2 seconds to enter the menu of valve model selection. Press
“ ”and“ ” buttons to select the requested model, then press “ ”
button to save the selection. Reconnect the power, the model will be
showed on display board.
Interlock function
It has a function of interlock to realize only one valve in regeneration
but the other valves are in service while several valves parallel in system.
In multi-steps treatment systems such as RO pre-treatment, when
several valves are in series, there is only one valve in regeneration or
washing to ensure pass water all the times. (Application refers to Figure
3-9)
Signal output(Take F99A/D as example)
There is a signal output connector on main control board. It is
applied for controlling external wiring (Refer to Figure 3-1 to Figure 3-8).
There are two kinds of output modes: b-01 mode: Turn on when
start regeneration and shut off at the end of regeneration; b-02 mode:
Signal is only available at intervals of each status.
4
MODEL 53515/53615/63515/63615/73515/73615
5
MODEL 53515/53615/63515/63615/73515/73615
Items Requirement
Water
0.2MPa~0.6MPa
Working pressure
conditions Water
5℃~50℃
temperature
Environment
5℃~50℃
temperature
Working Relative
≤95%(25℃)
environment humidity
Electrical
AC100~240V/50~60Hz
facility
Filter (53515/53615)<20FTU
Water
Down-flow regeneration softener (63515/63615)<5FTU
turbidity
Up-flow regeneration softener (73515/73615)<2FTU
+ +
Water First Grade Na < 6.5mmol/L ; Second Grade Na <
Inlet water hardness 10mmol/L
quality Free chlorine <0.1mg/L
2+
Iron <0.3mg/L
CODMn <2mg/L(O2)
6
MODEL 53515/53615/63515/63615/73515/73615
In the above table, First Grade Na+ represents First Grade Na+
Exchanger. Second Grade Na+ represents Second Grade Na+
Exchanger.
When the water turbidity exceeds the conditions, a filter should be
installed on the inlet of control valve.
When the water hardness exceeds the conditions, the outlet water
hardness will hardly reach the requirement of boiler feed water (0.03
mmol/L). It is suggested to adopt second grade softener.
1.4. Product Structure and Technical Parameters
A. Product dimension (The appearance is just for reference. It is
subjected to the real product.)
Remark:
Remove the flow meter from 53615, it will be 53515.
7
MODEL 53515/53615/63515/63615/73515/73615
Remark:
Remove the flow meter from 63615, it will be 63515.
8
MODEL 53515/53615/63515/63615/73515/73615
Remark:
Remove the flow meter from 73615, it will be 73515.
B. Technical parameter
Transformer Output: DC24V/1.5A
Connector Size Flow Rate
3
m /h Remark
Model Inlet/ Brine Line
Drain Base Riser Pipe @0.2MPa
Outlet Connector
53615 Filter,
1-1/2”D-GB(Outer Refer to
Meter type
diameter 50mm)or flow Rate
2″M 2″M /
4″-8UN 1.9”OD(Outer on P27 Filter,
53515 diameter 48.3mm) Time Clock
type
63615 2” M 1.5”M 3/4”M 4”-8UN 1-1/2"D-GB 15 DF softener,
9
MODEL 53515/53615/63515/63615/73515/73615
1.5. Installation
A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits should be
accomplished by professional to ensure the product can operate
normally.
Perform installation according to the relative pipeline regulations
and the specification of Water Inlet, Water Outlet, Drain Outlet, and Brine
Line Connector.
B. Device location
①The filter or softener should be located close to drain.
②Ensure the unit is installed in enough space for operating and
maintenance.
③Brine tank needs to be close to softener.
④The unit should be kept away from the heater and not be exposed to
outdoor. Sunshine or rain will cause the system damage.
⑤Please avoid installing the system in circumstance of acid/alkaline,
magnetic or strong vibration circumstance, because above factors will
cause the system disorder.
⑥Do not install the filter or softener, drain pipeline or overflow pipe in
circumstance which temperature may drop below 5℃, or above 45℃.
10
MODEL 53515/53615/63515/63615/73515/73615
⑦Install the system in the place where with the minimum loss in case of
water leakage.
C. Pipeline installation (Take 63615 as example)
① Install control valve
a. As the Figure 1-1 shows, select
the riser pipe with 50mm OD, glue
the riser pipe to the bottom strainer
and put it into the mineral tank, cut
off the exceeding pipe out of tank
top opening and make external
rounding.
b. Fill the resin to the tank, and the
height is accordance with the design
code.
c. Install the top strainer to the
valve.
d. Insert the riser tube into control
valve and screw tight control valve.
Note:
●The length of riser pipe should be neither 2mm higher nor 5mm
lower than tank top opening, and its top end should be rounded to
avoid damage of O-ring inside the valve.
●Avoid filling floccules substance together with resin to the mineral
tank.
● Avoid O-ring inside control valve fall out while rotating it on the
tank.
② Install flow meter
As Figure1-2 shows, put the sealing ring into nut of flow meter,
screw in water outlet; insert the sensor into flow meter.
11
MODEL 53515/53615/63515/63615/73515/73615
③ Pipeline connection
a. As Figure 1-3 shows, install a pressure gauge in water inlet.
b. Install valves A.B.C.D in inlet, outlet, inlet pipeline and outlet pipeline.
Valve D is a sampling valve.
c. Inlet pipeline should be in parallel with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.
Note:
●If making a soldered copper installation, do all sweat soldering
before connecting pipes to the valve. Torch heat will damage
plastic parts.
●When turning threaded pipe fittings onto plastic fitting, do not use
excessive force to make threads misaligned or break valve.
●If the valve belongs to time clock type (63515/73515), there are no
12
MODEL 53515/53615/63515/63615/73515/73615
step ②.
④ Install drain pipeline (If no special requirement, the standard DLFC is
No.7703)
a. Based on the table on P26, if tank diameter is 900 mm, install as step
d. If the tank size is 750 mm or 1000mm, you need to ask supplier for
another injector & DLFC. Install it as below steps.
b. Change 7703 to the corresponding injector for the tank which is 750
mm or 1000mm.
c. Change DLFC to the corresponding DLFC for the tank which is 750
mm or 1000mm..
d. Insert drain line flow
control into drain hose
connector, then screw it into
drain outlet, and lock it.
e. Glue the drain outlet with
UPVC (DN40). Put drain
outlet pipe to sewer as
showed in the Figure 1-4.
Note:
●Control valve should be higher than drain outlet, and be better not
far from the drain hose.
●Be sure not connect drain with sewer directly, and leave a certain
space between them, avoid wastewater being absorbed to the water
treatment equipment.
⑤ Connect brine tube
a. As Figure1-5 shows, use UPVC (DN20) to connect brine valve with
brine line connector.
Note:
● Keep brine line short and smooth. Elbows should be less than
four to avoid brine tube blocked.
13
MODEL 53515/53615/63515/63615/73515/73615
Figure 1-6
15
MODEL 53515/53615/63515/63615/73515/73615
16
MODEL 53515/53615/63515/63615/73515/73615
Regenerati
02:00 02:00 00:00~23:59 Regeneration time: “:” lights on
on Time
Resin
500 500 20-2000 Resin volume in brine tank (L)
Volume
Feed
Water Yd1.2 1.2 0.1-9.9 Feed water hardness (mmol/L)
Hardness
Exchange Relate to the raw water hardness. When
AL.65 0.65 0.30-0.99
Factor hardness is higher, the factor is smaller.
Water
Water treatment capacity in one circle
Treatment 200 0~9999 9 3
(m )
Capacity
Interval
Backwash F-00 00 00~20 Only suited for 73515/73615
Times
Rinsing
F-00 00 Only suited for 53515/53615
Frequenc 00~20
y
Backwash
10:00 0~99:59 Backwash time (Minute : Second)
Time
Brine Draw
60:00 0~99:59 Brine draw time (Minute : Second)
Time
17
MODEL 53515/53615/63515/63615/73515/73615
Slow Rinse
45:00 0~99:59 Slow rinse time (Minute : Second)
Time
Fast Rinse
10:00 0~99:59 Fast rinse time (Minute : Second)
Time
Brine Refill
05:00 0~99:59 Brine refill time (Minute : Second)
Time
Maximum
Regenerate on the day even though the
Interval
H-30 30 0~40 available volume of treated water does
Regenerati
not drop to zero (0).
on Days
Mode b-01: signal will turn on during the
Output regeneration (refer to P3)
01 or 02
Control b-01 01 Mode b-02: Signal is only available at
Mode intervals of regeneration cycles and in
service. (refer to the P3)
18
MODEL 53515/53615/63515/63615/73515/73615
H/C; In Brine Refill status, it shows Figure J/C. In each status, every
figure shows 15 seconds.
Above displays are taking the Meter Type for example. For the Time
Clock Type, it shows the rest days, such as 1-03D.
The display screen will only show “-00-” when the electrical motor is
running.
The time of day figure“” flash continuously, such as “12:12” flashes,
indicates long outage of power. It reminds users to reset the time of
day.
The display will show the error code, such as “-E1-” when the system is
in error.
Working process: Service→ Backwash→ Brine Draw→ Slow Rinse →
Fast Rinse→ Brine Refill → Service.
C. Usage
After being accomplished installation, parameter setting and trial
running, the valve could be put into use. In order to ensure the quality of
outlet water can reach the requirement, the user should complete the
below works:
① Ensure that there is solid salt all the time in the brine tank when this
valve is used for softening. The brine tank should be added the
crystalline coarse salt only, at least 99.5% pure, forbidding use the small
salt and iodized salt.
② Test the outlet water and raw water hardness at regular time. When
the outlet water hardness is unqualified, please press the after unlock
the buttons and the valve will temporarily regenerate again (It will not
affect the original set operation cycle.)
③When the raw water hardness changes a lot, you can adjust the water
treatment capacity as follow:
Press and hold both and for 5 seconds to unlock the buttons.
Press , and the will light on, then press , the digital area shows
the control mode. If it shows A-01 or A-02, press to let the digital
area show the given water treatment capacity (If the control mode shows
A-03 or A-04, then press four times, the digital area will show the
19
MODEL 53515/53615/63515/63615/73515/73615
3. Applications
20
MODEL 53515/53615/63515/63615/73515/73615
21
MODEL 53515/53615/63515/63615/73515/73615
22
MODEL 53515/53615/63515/63615/73515/73615
Functions on PC board:
Function Application Explanation
Used in strict requirements regarding no
Outlet Solenoid Valve hard water flowing from outlet or
Signal
controlling the liquid level in water tank.
Output
Increase pressure for regeneration or
Connector
washing. Use the liquid level controller to
b-01 Inlet Pump
control inlet pump to ensure there is water
in tank.
Signal
When inlet pressure is high, it needs to
Output Inlet Solenoid Valve or
close water inlet to protect motor when
Connector Inlet Pump
valve is rotating.
b-02
Pressure When valve is rotating, pressure relief
Control the inlet bypass
Relief connector opened to prevent pressure
to release pressure
Connector increasing rapidly.
To ensure only one Use in RO pre-treatment, water supply
Interlock control valve together but regeneration in turn,
Connector regenerate or wash in second grade ion exchange equipment,
system. etc.
Remote Receive signal to make It is used for on-line inspection system,
Handling the control valve rotate connected with PC to realize
Connector to next status. automatically or remote controlling valve.
23
MODEL 53515/53615/63515/63615/73515/73615
Function:
When valve is in service status, if soft water tank is short of water,
solenoid valve will open to supply soft water, but if water tank has
enough water, solenoid valve will close, so no soft water supplied to the
tank.
When the valve is in backwash or other regeneration status, there is
no signal output. So solenoid valve will close, and no raw water flows
into soft water tank.
②Control Inlet Solenoid valve (Set b-02)
Instruction: When inlet pressure exceeds 0.6MPa, install a solenoid
valve on inlet. Control mode is b-02. Pressure is relieved when valve
switch, the wiring refers to Figure 3-2. As Figure 3-3 shows, it also can
use the pressure relief connector to work.
24
MODEL 53515/53615/63515/63615/73515/73615
Instruction:
When inlet pressure is high, install a solenoid valve on inlet to
ensure valve switches properly. The solenoid valve will open when valve
is exactly at status of Service, Backwash, Brine & Slow Rinse, Brine
Refill and Fast Rinse. When valve is switching, solenoid valve is closed,
no water flows into valve to ensure valve switching properly. It could
prevent the problem of mixing water and water hammer.
Use interlock cable to realize valves in parallel and series in same
system which is suited for RO pretreatment system or second grade Na+
system. The wiring refers to Figure 3-4:
25
MODEL 53515/53615/63515/63615/73515/73615
Function:
When valve is in service status, if water tank is short of water, pump
starts working, but if water tank has enough water, the switch of liquid
level controller is closed, so pump doesn’t work.
When valve in regeneration cycle, inlet always has water no matter
what is water condition in water tank. As Runxin valve, no water passes
outlet in regeneration cycle, it ensures no water fill into brine tank. A
liquid switch at the top opening well or in middle water tank in RO system
protects pump from working without water in case of out of raw water.
3).Liquid Level Switch in Water Tank Controls Inlet Pump (Three-phase,
Figure 3-6) (Set b-01)
26
MODEL 53515/53615/63515/63615/73515/73615
27
MODEL 53515/53615/63515/63615/73515/73615
B. Interlock
Instruction: In the parallel water treatment system, it ensures only one
valve in regeneration or washing cycle and (n-1) valves in service, that is,
realizing the function of supplying water simultaneously and
regenerating individually.
In the series water treatment system which is suited for RO
pretreatment system or second grade Na+ system, it ensures only one
valve in regeneration or washing cycle and every grade has water when
in regeneration or washing. Wiring refers to Figure 3-9:
Use interlock cable to connect CN8 to CN7 on next valve in the loop.
One system with several valves, if interlock cable is disconnected, the
system is divided into two individual systems.
C. Pressure Relief Output
Runxin valve will cut off feeding water to drain line when it switches
in regeneration cycles. Thus in some water treatment systems, e.g.
Deep Well, one booster pump was installed on the inlet to increase the
system water feeding pressure, this cut-off will cause pressure on inlet
rising so fast to damage the valve. Pressure Relief Output can be used
to avoid this problem. The wiring refers to Figure 3-10.
28
MODEL 53515/53615/63515/63615/73515/73615
29
MODEL 53515/53615/63515/63615/73515/73615
F. Series System
This is 2 or more than 2 valve systems, all in service, with one flow
meter for the entire system. For the time type valve, the regeneration
time should be set and adjusted to the Max; for the meter type valve,
connect its signal output connector with the remote handle connector of
the time type valve. That can realize the function of supplying water
simultaneously and regenerating orderly. The wiring refers to Figure
3-13.
3.3. System Configuration and Flow Rate Curve
A. Product Configuration
①. 63515/63615/73715/73615 softener valve configuration with tank, resin
volume, brine tank and injector.
30
MODEL 53515/53615/63515/63615/73515/73615
Attention: The flow rate of A/C filter calculation is based on linear velocity
12m/h, backwash flow rate calculation is based on backwash intensity
10L/(㎡*s); The flow rate of sand filter calculation is based on linear
velocity 25m/h, backwash flow rate calculation is based on backwash
intensity 15/(㎡*s).
B. Flow Rate Characteristic
1).Pressure-flow Rate Curve
Softener valve: 63515/63615/73515/73615
31
MODEL 53515/53615/63515/63615/73515/73615
32
MODEL 53515/53615/63515/63615/73515/73615
34
MODEL 53515/53615/63515/63615/73515/73615
35
MODEL 53515/53615/63515/63615/73515/73615
36
MODEL 53515/53615/63515/63615/73515/73615
37
MODEL 53515/53615/63515/63615/73515/73615
38
MODEL 53515/53615/63515/63615/73515/73615
39
MODEL 53515/53615/63515/63615/73515/73615
lights on and enter in the process of Brine & Slow Rinse. The air
check valve will turn off when control valve finished brine draw then slow
rinse starts to work. It is about 60~65minutes for whole process.
E. Press , and turn the status from Brine & Slow Rinse to Fast Rinse.
lights on. It takes about 10~15 minutes, take out some outlet water
for testing: if the water hardness reach the requirement, and the
chloridion in the water is almost the same compared with the inlet water,
then go to the next step.
F. Press , and turn the status from Fast Rinse to Brine Refill.
lights on and it indicates the brine tank is being refilled with water to the
required level. It takes about 5~6 minutes, then add solid salt to the
brine tank.
G. Press , making the control valve return to Service status; lights
on and start to running.
Note:
40
MODEL 53515/53615/63515/63615/73515/73615
When the control valve enters into the regeneration status, all program
can be finished automatically according to the setting time; if you want
one of steps to be terminated early, you can press .
If water inflows too fast, the media in tank will be damaged. When
water inflows slowly, there is a sound of air emptying from drain pipeline.
After changing resin, please empty air in the resin according to the
above Step C.
In the process of trial running, please check the water situation in all
positions, and ensure there is no resin leakage.
The time for Backwash, Brine Draw, Slow Rinse, Fast Rinse and Brine
Refill status can be set and executed according to the calculation in the
formula or suggested from the control valve suppliers.
3.7. Trouble-Shooting
41
MODEL 53515/53615/63515/63615/73515/73615
42
MODEL 53515/53615/63515/63615/73515/73615
valve but power failure E. Repair or replace safety brine
while salting.
valve.
E. Brine refill is out of
F. Replace ball valve.
control.
F. Ball valve doesn’t close.
A. Clean the water supply pipe.
B. Clean valve and add resin
A. Iron in the water supply cleaning chemical, increase
pipe. frequency of regeneration.
7. Pressure
B. Iron mass in the softener. C. Check backwash, brine draw
lost or rust in
C. Fouled resin bed and brine tank refill. Increase
pipeline
D. Too much iron in the raw frequency of regeneration and
water. backwash time.
D. Iron removal equipment is
required to install before softening.
8. Loss of A. Air in water system. A. Assure that well system has
mineral B. Strainer broken. proper air eliminator control.
through drain C. Improperly sized drain B. Replace new bottom strainer.
line. line control.. C. Check for proper drain rate.
A. Locating signal wring
A. Check and connect locating
breakdown.
signal wiring.
9. Control B. Controller is faulty.
B. Replace controller.
cycle C. Foreign material stuck
C. Take out foreign material.
continuously. the driving gear.
D. Check and reset program
D. Time of regeneration
setting.
steps were set to zero.
A. Check and repair valve body or
10. Drain A. Internal valve leak. replace it.
flows B. Power off when in B. Adjust valve to service position
continuously. backwash or fast rinse. or turn off bypass valve and restart
when electricity supply.
A. Water pressure is too low
11. or not stable. A. Increase water pressure.
Interrupted or B. Injector is plugged or B. Clean or replace injector.
irregular faulty. C. Check and find the reason.
brine. C. Air in resin tank. D. Clean the floccules in resin tank.
D. Floccules in resin tank
43
MODEL 53515/53615/63515/63615/73515/73615
during up-flow
regeneration.
A. Foreign material in valve
which makes valve can’t be
A. Clean foreign material in valve
12. Water closed completely.
body.
flows out B. Hard water mixed in
B. Change valve core or sealing
from drain or valve body.
ring.
brine pipe C. Water pressure is too
C. Reduce water pressure or use
after high which results in valve
pressure relief function.
regeneration not getting the right status.
D. Repair or replace ball valve.
D. Ball valve doesn’t
shut-off completely.
A. Foreign material in
injector or injector fails to
13. Salt
work. A. Clean and repair injector.
water in
B. Brine valve can’t be B. Repair brine valve and clean it.
outflow
shut-off. C. Extend fast rinse time.
pipeline.
C. Time of fast rinse is too
short.
A. Regenerate according to the
correct operation requirement.
A. Regenerate not properly. B. Increase backwash flow rate
B. Fouled resin bed. and times, clean or change resin.
C. Salt setting is not proper. C. Readjust brine drawing time.
14. Unit D. Softener setting is not D. According to the test of outlet
capacity proper. water, recount and reset.
decreases. E. Raw water quality E. Regenerate unit by manual
deteriorated. temporary then reset regeneration
F. Turbine of flow meter has cycle.
already gotten stuck. F. Disassemble flow meter and
clean it or replace a new flow
meter.
B. Controller Fault
Problem Cause Correction
44
MODEL 53515/53615/63515/63615/73515/73615
6. E3 or E4
A. Control board is faulty. A. Replace control board.
Flashes
45
MODEL 53515/53615/63515/63615/73515/73615
46
MODEL 53515/53615/63515/63615/73515/73615
Screw, Cross
3 8909010 3 25 Front Cover 8300025 1
ST3 X16
Three-core
7 Fixed Disk 8469098 1 29 5517003 1
Spring
Flow Meter
9 Shaft 8258037 1 31 6386003 1
Sensor
Anti-friction
10 8216028 1 32 Wire for Power 5513001 1
Washer
O-ring
11 8378110 2 33 Locking Ring 8994009 1
59.92X3.53
O-ring
12 8378245 2 34 Small Gear 8241008 1
142.24X5.33
Screw, Cross
15 8909008 14 37 Cable Clip 8126002 1
ST3X10
Screw, Cross
16 Gear 8241040 1 38 8902007 1
Set M4X20
Screw, Cross Screw, Cross
17 8909018 1 39 8909013 4
ST5X20 Set ST4X12
Screw, Cross
18 Fixed Base 8109079 1 40 8902005 1
Set M4X12
Screw, Cross
19 Control Board 6382091 1 41 8902008 4
Set M4X25
Screw, Cross
20 8909004 4 42 Valve Body 5022139 1
ST2.2X6.5
Wire for Locating
21 5511023 1 43 Flow Meter 5447003 1
Board
22 Dust Cover 5005057 1 44 Connector 8458018 1
Note:
Compared with 53615, there are no item no.31 and item no.43 for
53515.
47
MODEL 53515/53615/63515/63615/73515/73615
48
MODEL 53515/53615/63515/63615/73515/73615
Hexagonal Bolt
10 5851006 3 39 Front Cover 8300025 1
Set M5×20
Electronic Ball
12 6922075 1 41 Cable Clip 8126001 1
Valve
Three-core
14 O-ring 38.7X2.65 8378243 1 43 5517003 1
Spring
Flow Meter
16 O-ring 34.5X2.65 8378242 1 45 6386003 1
Sensor
Screw, Cross
17 8909010 3 46 Wire for Power 5513001 1
ST3X16
Screw, Cross
18 8909003 9 47 Locking Ring 8994009 1
ST3.9X19
49
MODEL 53515/53615/63515/63615/73515/73615
Screw, Cross
23 Shaft 8258037 1 52 8902007 1
Set M4X20
Anti-friction Screw, Cross
24 8216028 1 53 8909013 4
Washer Set ST4X12
O-ring Screw, Cross
25 8378110 2 54 8902005 1
59.92X3.53 Set M4X12
O-ring Screw, Cross
26 8378245 2 55 8902008 4
142.24X5.33 Set M4X25
Screw, Cross
29 8909008 14 58 Connector 8458018 1
ST3X10
Note:
Compared with 63615, there are no item no.45 and item no.57 for
63515.
50
MODEL 53515/53615/63515/63615/73515/73615
51
MODEL 53515/53615/63515/63615/73515/73615
Hexagonal Bolt
10 5851006 3 40 Front Cover 8300025 1
Set M5×20
Electronic Ball
12 6922075 1 42 Cable Clip 8126001 1
Valve
Three-core
14 O-ring 38.7X2.65 8378243 1 44 5517003 1
Spring
Flow Meter
16 O-ring 34.5X2.65 8378242 1 46 6386003 1
Sensor
Screw, Cross
17 8909010 3 47 Wire for Power 5513001 1
ST3X16
Screw, Cross
18 8909003 9 48 Locking Ring 8994009 1
ST3.9X19
52
MODEL 53515/53615/63515/63615/73515/73615
Screw, Cross
30 8909008 14
ST3X10
Note:
Compared with 73615, there are no item no.46 and item no.58 for
73515
53
MODEL 53515/53615/63515/63615/73515/73615
Animated
1 8947004 1
Connector
2 Seal Ring 8371008 1
3 Connector 8458016 1
6 Turbine 5436005 1
7 Bush 8210002 1
54
MODEL 53515/53615/63515/63615/73515/73615
4. Warranty Card
Dear client:
This warranty card is the guarantee proof of RUNXIN brand
multi-functional flow control valve. It is kept by client self. You could get
the after-sales services from the supplier which is appointed by RUNXIN
manufacturer. Please keep it properly. It couldn’t be retrieved if lost. It
couldn’t be repaired free of charge under the below conditions:
1. Guarantee period expired. (One year)
2. Damage resulting from using, maintenance, and keeping that are not
in accordance with the instruction.
3. Damage resulting from repairing not by the appointed maintenance
personnel.
4. Content in guarantee proof is unconfirmed with the label on the real
good or be altered.
5. Damage resulting from force majeure.
Product Multi-functional Flow Control Valve
Name for Water Treatment Systems
Code of
Model
Valve Body
Purchase
Company Tel/Cel.
Name
Problem
Solution
55
MODEL 53515/53615/63515/63615/73515/73615
End-user
Company Tel/Cel.
Name
Purchase
Company Tel/Cel.
Name
Model Code of Valve Body
Raw Water Hardness
Tank Size φ × Resin Tank Size L
mmol/L
Water source:
Water Treatment
Ground-water□ 3
Backwash Time min
Capacity m
Tap Water □
Brine Draw Slow Rinse
Brine Refill Time min Fast Rinse Time min
Time min Time min
Problem
Description