DSEBC2410Ei SPECIFICATIONS
FREQUENCY RANGE
48 Hz to 64 Hz (L to N)
DC OUTPUT
OUTPUT
10 A DC at 12 V & 24 V DC
EFFICIENCY
>86%
REGULATION
LINE
<0.5%
LOAD
2%
PROTECTIONS
Short circuit
DC over voltage
DC over current
Reverse polarity
Over temperature
AC under & over voltage
Battery charger failure
DIMENSIONS
Display & Meters Variant Display Variant OVERALL
170 mm x 305 mm x 116 mm
6.7” x 12” x 4.6”
WEIGHT
2.3 kg
The DSEBC2410Ei is an enclosed The DSEBC2410Ei has been Compatible Battery Profiles
OPERATING TEMPERATURE RANGE
intelligent battery charger designed extensively tested and can withstand - Lead Acid -30 ºC to +55 ºC
to work with multiple battery types high levels of vibration to operate - Lead Crystal -22 ºF to +131 ºF
across a wide range of applications. within industrial environments. - Ni-Cad 18 Cell
- Ni-Cad 20 Cell OPERATING TEMPERATURE RANGE
(DE-RATE TO OUTPUT)
The advanced technology has been The DSEBC2410Ei is UL listed for use - Calcium -30 ºC to +80 ºC
developed to automatically detect on emergency generators and is fully - Lithium Phosphate -22 ºF to +176 ºF
system settings and charging profiles compliant to NFPA110. - VRLA-AGM
including cell voltage and boost - VRLA-GEL
voltage to provide high-levels of The lightweight enclosed design
charging support. allows the charger to be installed in Charger Variants
multiple environments simply and
Additional high-level features include quickly. BC2410Ei-01
external system integration via 12/24 Volt 10 Amp Enclosed Battery
Modbus RS485, remote temperature The charger can be used as a power Charger (Display)
compensation, short-circuit and supply and multiple chargers can be BC2410Ei-02
reverse polarity protection, multi- installed in parallel to achieve higher 12/24 Volt 10 Amp Enclosed Battery
stage charging regimes, configurable charging / power supply currents. Charger (Display & Meters)
charging curves and battery life BC2410Ei-03
optimisation. 12/24 Volt 10 Amp Enclosed Battery
Charger (Meters)
RELATED MATERIALS
TITLE PART NO. Configurable
BC2410Ei Configuration Suite PC Software Manual 057-315
BC2410Ei Installation Instructions 053-251 for use as
BC2410Ei Operators Manual 057-316 a 5 Amp
DSE2541 Installation Instructions 053-154 Charger
DSE2541 Data Sheet 055-160
ELECTRO-MAGNETIC COMPATIBILITY
Enclosed Intelligent Battery Charger - 10 Amp 12 Volt / 24 Volt BS EN 61000-6-2
EMC Generic Immunity Standard for
the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
ADVANCED FEATURES Full Protection KEY BENEFITS OPERATING TEMPERATURE RANGE
• Intelligent two, three and four stage • AC input under / over voltage • Multiple chargers can be connected BS EN 60068-2-1
charging profiles • Battery charger output over voltage in parallel to achieve higher Ab/Ae Cold Test -30 ºC
• Configurable charging curves • Battery charger output over current charging / power supply currents BS EN 60068-2-2
Bb/Be Dry Heat +80 ºC
• 12 V / 24 V auto voltage detection • Automatic power de-rating at high • Can be permanently connected to a * Refer to de-rating curve in the DSE9000
for multiple battery types ambient temperatures battery and a mains (utility) supply Operator Manual
• Short-circuit & reverse polarity • Battery charger failure indication • UL listed
VIBRATION
protection • NFPA110 compliant BS EN 60068-2-6
• Multi-stage charging regimes Automatic Boost Mode • Tested to industrial standards Ten sweeps in each of three
• Adjustable current limit • Timed boost to equalise cells and • Flexible installation options major axes
5 Hz to 8 Hz @ +/-7.5 mm,
• Battery life optimisation improve battery performance and life • Energy efficient design
8 Hz to 500 Hz @ 2 gn
• Option to be used as a battery • Withstands harsh operating
charger, power supply or both Power Save Mode environments HUMIDITY
• Automatic / manual boost and • Eco mode automatically activates • Next generation charging BS EN 60068-2-30
Db Damp Heat Cyclic 20/55 oC
storage charge functionality to help when battery reaches full charge technology @ 95% RH 48 Hours
maintain battery condition • Deep-sleep mode reduces current BS EN 60068-2-78
• Digital micro-processor technology Communication consumption from the battery down Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours
• Remote temperature compensation • RS485 Modbus RTU external to below 10mA when mains is not
for battery charging system integration present. SHOCK
• Low output ripple and superb line • DSE Configuration Suite BS EN 60068-2-27
regulation software Three shocks in each of three major axes
15 gn in 11 mS
• Maximum 91% operating efficiency • DSE2541 external remote display
• Deep-sleep mode option
1ph
N
DSEBC2410Ei
7
OTHER
PT1000 ONLY
1 1