You are on page 1of 12

Project Job Ref.

J110_Concourse Floor
Section Sheet no./rev.
Detail 61 1
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

STEEL TO CONCRETE CONNECTION DESIGN


In accordance with EN1992-1-1:2004 +A1:2014 Incorporating corrigenda January 2008, November 2010 and January
2014, EN1993-1-1:2005 Incorporating corrigenda February 2006 and April 2009, EN1993-1-8:2005 Incorporating
corrigenda December 2005, September 2006 and July 2009, and EN1994-1-1:2004 Incorporating corrigenda April
2009. and the Singapore National Annex.
Tedds calculation version 1.0.04

Summary Results

Description Units Design Resistance Utilisation Result

Bolt group kN 950 1463.3 0.649 PASS

Fin plate kN 950 2003.9 0.474 PASS

Web in shear kN 950 5043.7 0.188 PASS

Plate & bolts - Tying kN 50 2450 0.020 PASS

Beam web - Tying kN 50 5212.7 0.010 PASS

Shear stud kN 38.5 81.7 0.472 PASS

Rebar size kN 124.4 124.5 0.999 PASS

Plate bending kN 207.3 254.6 0.814 PASS

Plate vertical bending kN 207.3 474.6 0.437 PASS

Rebar weld mm 42 4.6 0.109 PASS

Wall punch shear N/mm 2 0.01 0.35 0.018 PASS

450 x 925 x 25 mm plate


w/ 28No. 19 mm  shear studs
153.4 x 840 x 16 mm plate
w/ 22No. M20 bolts

50 kN

950 kN UB 1016x305x393
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 2
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Connection Details
Design forces
Design shear; VEd = 950 kN
Design tying; FEd = 50 kN

Partial factors
Resistance of cross section; M0 = 1.00
Resistance of members to instability; M1 = 1.00
Cross section in tension to fracture; M2,c = 1.10
Resistance of bolts; M2,b = 1.25
Structural integrity; M,u = 1.10
Shear connectors; V = 1.25
Reinforcing steel at ULS; s,1 = 1.15
Reinforcing steel at SLS; s,2 = 1.00
Concrete at ULS; c,1 = 1.50
Concrete at SLS; c,2 = 1.20

Connected beam details


Section name; UB 1016x305x393
Steel grade; S355
Yield strength; fy,b = 335 N/mm 2
Ultimate strength; fu,b =470 N/mm 2

Fin plate details


Plate height; hfp = 840 mm
Plate width; bfp = 153.4 mm
Plate thickness; tfp = 16 mm
Gap to plate; bgap = 30 mm
Yield strength; fy,fp = 345 N/mm 2
Ultimate strength; fu,fp = 470 N/mm 2
Weld leg size; sw,fp = 10 mm

Bolt details
Bolt size; M20
Bolt diameter; db,fp = 20 mm
Bolt hole diameter; d0,fp = 22 mm
Number of bolt rows; n1,fp = 11
Number of bolt lines; n2,fp = 2
End distance; e1,fp = 45 mm
Edge distance; e2,fp = 45 mm
Pitch distance; p1,fp = 75 mm
Distance between bolt lines; p2,fp = 48.4 mm
Distance to beam edge; e1,b = 120 mm
Distance to beam end; e2,b = 30 mm
Bolt grade; 10.9
Yield strength; fy,bolt = 900 N/mm 2
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 3
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Ultimate strength; fu,bolt = 1000 N/mm 2

16
75
45

75
75
75
75
75
75

840
75
75
75
75
75
45
60
45
48.4

Connected beam - Bolt group check


Bolt shear
Nominal gap to face of the wall; gapnom = bgap + phori = 65 mm
Maximum gap to face of the wall; gapmax = bgap + 2  phori = 100 mm
Assumed line of shear transfer; zv = pinset + gapmax + e2b + p2,fp/2 = 154.2 mm
Coefficients; lb,v = n1,fp / 2  p2,fp2 + 1/6  n1,fp  (n1,fp2 - 1)  p1,fp2 = 1250384.1 mm 2
b,v = zv  p2,fp / (2  lb,v) = 0
b,v = zv  p1,fp / (2  lb,v)  (n1,fp - 1) = 0.05
Bolt shear area; As = 245 mm 2
Bolt shear coefficient; v = 0.5
Individual bolt shear resistance; Fv,Rd = v  fu,bolt  As / M2,b = 98 kN
Bolt group shear resistance; VRd,b,v = Nb,tot  Fv,Rd / ((1 + b,v  Nb,tot)2 + (b,v  Nb,tot)2) = 1463.34 kN
Utilisation; VEd / VRd,b,v = 0.649
Bolt bearing in the fin plate
Vertical coefficients; k1,ver,pl = Min(2.8  e2,fp / d0,fp - 1.7, 1.4  p2,fp / d0,fp - 1.7, 2.5) = 1.38
b,ver,pl = Min(e1,fp / (3  d0,fp), p1,fp / (3  d0,fp) - 1/4, fu,bolt / fu,fp, 1) = 0.68
Horizontal coefficients; k1,hor,pl = Min(2.8  e1,fp / d0,fp - 1.7, 1.4  p1,fp / d0,fp - 1.7, 2.5) = 2.5
b,hor,pl = Min(e2,fp / (3  d0,fp), p2,fp / (3  d0,fp) - 1/4, fu,bolt / fu,fp, 1) = 0.48
Vertical resistance single bolt; Fb,ver,pl,Rd = k1,ver,pl  b,ver,pl  fu,fp  db,fp  tfp / M2,b = 113.21 kN
Horizontal resistance single bolt; Fb,hor,pl,Rd = k1,hor,pl  b,hor,pl  fu,fp  db,fp  tfp / M2,b = 145.39 kN
Bolt bearing resistance; Vpl,Rd = Nb,tot / (((1 + b,v  Nb,tot) / Fb,ver,pl,Rd)2 + (b,v  Nb,tot / Fb,hor,pl,Rd)2) =
1875.64 kN
Utilisation; VEd / Vpl,Rd = 0.506
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 4
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Bolt bearing in the beam web


Vertical coefficients; k1,ver,wb = Min(2.8  e2,b / d0,fp - 1.7, 1.4  p2,fp / d0,fp - 1.7, 2.5) = 1.38
b,ver,wb = Min(e1,b / (3  d0,fp), p1,fp / (3  d0,fp) - 1/4, fu,bolt / fu,b, 1) = 0.89
Horizontal coefficients; k1,hor,wb = Min(2.8  e1,b / d0,fp - 1.7, 1.4  p1,fp / d0,fp - 1.7, 2.5) = 2.5
b,hor,wb = Min(e2,b / (3  d0,fp), p2,fp / (3  d0,fp) - 1/4, fu,bolt / fu,b, 1) = 0.45
Vertical resistance single bolt; Fb,ver,wb,Rd = k1,ver,wb  b,ver,wb  fu,b  db,fp  tw / M2,b = 224.44 kN
Horizontal resistance single bolt; Fb,hor,wb,Rd = k1,hor,wb  b,hor,wb  fu,b  db,fp  tw / M2,b = 208.51 kN
Bolt bearing resistance; Vwb,Rd = Nb,tot / (((1 + b,v  Nb,tot) / Fb,ver,wb,Rd)2 + (b,v  Nb,tot / Fb,hor,wb,Rd)2)
= 3231.34 kN
Utilisation; VEd / Vwb,Rd = 0.294
PASS - Bolt group resistance greater than design force

Fin Plate Shear and Bending Check


Shear
Net shear area; Av,net = tfp  (hfp - n1,fp  d0,fp) = 9568 mm 2
Net area subjected to tension; Ant = tfp  (p2,fp + e2,fp - 3  d0,fp/2) = 966.4 mm 2
Net area subjected to shear; Anv = tfp  (hfp - e1,fp - (n1,fp - 0.5)  d0,fp) = 9024 mm 2
Gross section shear resistance; VRd,g,pl = hfp  tfp / 1.27  fy,fp / ((3)  M0) = 2107.92 kN
Net section shear resistance; VRd,n,pl = Av,net  fu,fp / ((3)  M2,c) = 2360.29 kN
Block tearing shear resistance; VRd,b,pl = 0.5  fu,fp  Ant / M2,c + fy,fp / (3)  Anv / M0 = 2003.91 kN
Shear resistance; VRd,min,pl = Min(VRd,g,pl, VRd,n,pl, VRd,b,pl) = 2003.91 kN
Utilisation; VEd / VRd,min,pl = 0.474
Bending
Distance to bolt line; zp = e2,b + gapmax + pinset = 130 mm
Lever arm; z = zp + p2,fp/2 = 154.2 mm
hp greater than 2.73z, bending check not required!
Lateral torsional buckling
Elastic modulus of plate; W el,p = tfp  hfp2 / 6 = 1881600 mm 3
Imperfection factor; LT = 0.76
Slenderness of plate; LT = 2.8/86.8  (zp  hfp / (1.5  tfp2))1/2 = 0.54
LT = 0.5  (1 +LT  (LT - 0.2) + LT2) = 0.78
Lateral torsional buckling reduction factor; LT = Min(1 / (LT + (LT2 - LT2)), 1) = 0.75
Plate bending resistance; VRd,bend = Min(W el,p / z  (LT  fy,fp) / (0.6  M1), W el,p / z  fy,fp / M0) =
4209.81 kN
Utilisation; VEd / VRd,bend = 0.226
PASS - Fin plate resistance greater than design force

Connected Beam - Web in Shear


Shear
Shear area; Av = (hb - 2  tf)  tw + (tw + 2  rb)  tf = 26350.8 mm 2
Net shear area; Av,net = Av - n1,fp  d0,fp  tw = 20446 mm 2
Gross section shear resistance; VRd,g,wb = Av  fy,b/((3)  M0) = 5096.57 kN
Net section shear resistance; VRd,n,wb = Av,net  fu,b/((3)  M2,c) = 5043.74 kN
Shear resistance; VRd,min,wb = Min(VRd,n,wb, VRd,g,wb) = 5043.74 kN
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 5
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Utilisation; VEd / VRd,min,wb = 0.188


Shear and bending interaction beam web
Shear resistance of web horizontal; Vpl,AB,Rd = tw  (e2b +p2,fp)  fy,b / ((3)  M0) = 369.99 kN
Shear resistance of web vertical; Vpl,BC,Rd = tw  (n1,fp - 1)  p1,fp  fy,b / ((3)  M0) = 3539.45 kN
Shear force of web vertical; VBC,Ed = VEd  (n1,fp - 1)  p1,fp / hb = 701.35 kN
Moment resistance of web vertical; Mc,BC,Rd = fy,b  tw/(6M0)  ((n1,fp - 1)  p1,fp)2 = 766.31 kNm
Moment resistance of web; Mc,wb,Rd = Mc,BC,Rd + Vpl,AB,Rd  (n1,fp - 1)  p1,fp = 1043.81 kNm
Design moment of web; Mc,wb,Ed = VEd  (zp + p2,fp) = 169.48 kNm
Utilisation; Mc,wb,Ed / Mc,wb,Rd = 0.162
PASS - Beam web resistance greater than design force

Fin Plate and Bolts - Structural Integrity Check


Tension resistance of fin plate
Net tension area of plate; Anet,p = tfp  (hfp - d0,fp  n1,fp) = 9568 mm 2
Net section tension resistance; FRd,n,pl = 0.9  Anet,p  fu,fp / M,u = 3679.33 kN
Case 1
Net area subject to tension; Ant,1,pl = tfp  ((n1,fp - 1)  p1,fp - (n1,fp - 1)  d0,fp) = 8480 mm 2
Net area subject to shear; Anv,1,pl = 2  tfp  (p2,fp + e2,fp - 3  d0,fp/2) = 1932.8 mm 2
Block tearing resistance; FRd,b,1,pl = fu,fp  Ant,1,pl / M,u + fy,fp/(3)  Anv,1,pl/M0 = 4008.26 kN
Case 2
Net area subject to tension; Ant,2,pl = tfp  ((n1,fp - 1)  p1,fp - (n1,fp - 0.5)  d0,fp + e1,fp) = 9024 mm 2
Net area subject to shear; Anv,2,pl = tfp  (p2,fp + e2,fp - 3  d0,fp/2) = 966.4 mm 2
Block tearing resistance; FRd,b,2,pl = fu,fp  Ant,2,pl / M,u + fy,fp/(3)  Anv,2,pl/M0 = 4048.2 kN
Tension resistance; FRd,u,pl = Min(FRd,b,1,pl, FRd,b,2,pl, FRd,n,pl) = 3679.33 kN
Utilisation; FEd / FRd,u,pl = 0.014
Bolt shear
Bolt coefficient; v = 0.5
Bolt shear area; As = 245 mm 2
Bolt individual shear resistance; Fv,u = v  fu,bolt  As / M,u = 111.36 kN
Bolt group shear resistance; FRd,u,Bv = Nb,tot  Fv,u = 2450 kN
Utilisation; FEd / FRd,u,Bv = 0.020
Bolt bearing in fin plate
Coefficients; b,pl = Min(e2,fp / (3  d0,fp), p2,fp / (3  d0,fp) - 1/4, fu,bolt / fu,fp, 1) = 0.483
k1,pl = Min(2.8  e1,fp / d0,fp - 1.7, 1.4  p1,fp / d0,fp - 1.7, 2.5) = 2.5
Individual bearing resistance; Fb,Rd,u,pl = k1,pl  b,pl  fu,fp  db,fp  tfp / M,u = 165.21 kN
Group bearing resistance; FRd,u,b = Nb,tot  Fb,Rd,u,pl = 3634.67 kN
Utilisation; FEd / FRd,u,b = 0.014
PASS - Plate and bolt resistance greater than design force

Connected Beam Web - Structural Integrity Check


Tension resistance of beam web
Net tension area of web; Anet,wb = tw  (hfp - d0,fp  n1,fp) = 14591.2 mm 2
Net section tension resistance; FRd,n,wb = 0.9  Anet,wb  fu,b / M,u = 5610.98 kN
Net area subject to tension; Ant,wb = tw  ((n1,fp - 1)  p1,fp - (n1,fp - 1)  d0,fp) = 12932 mm 2
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 6
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Net area subject to shear; Anv,wb = 2  tw  (p2,fp + e2b - 3  d0,fp/2) = 2215.5 mm 2


Block tension resistance; FRd,b,wb = fu,b  Ant,wb / M,u + fy,b  Anv,wb / ((3)  M0) = 5954 kN
Tension resistance; FRd,u,wb = Min(FRd,b,wb, FRd,n,wb) = 5610.98 kN
Utilisation; FEd / FRd,u,wb = 0.009
Bolt bearing in beam web
Coefficients; b,wb = Min(e2b / (3  d0,fp), p2,fp / (3  d0,fp) - 1/4, fu,bolt / fu,b, 1) = 0.455
k1,wb = Min(1.4  p1,fp / d0,fp - 1.7, 2.5) = 2.5
Individual bearing resistance; Fb,Rd,u,wb = k1,wb  b,wb  fu,b  db,fp  tw / M,u = 236.94 kN
Group bearing resistance; FRd,u,b = Nb,tot  Fb,Rd,u,wb = 5212.73 kN
Utilisation; FEd / FRd,u,b = 0.010
PASS - Supported beam web resistance greater than design force

Wall details
Wall thickness; twall = 1000 mm
Concrete cover; cwall = 30 mm
Vertical bar diameter; d0,r2 = 20 mm
Vertical bar spacing; p1,r2 = 200 mm
Horizontal bar diameter; d0,r1 = 20 mm
Horizontal bar spacing; p1,r1 = 200 mm
Concrete grade; C32/40
Characteristic compressive strength; fck = 32 N/mm 2

Embedded plate details


Plate height; hp = 925 mm
Plate width; bp = 450 mm
Plate thickness; tp = 25 mm
Yield strength; fy,p = 345 N/mm 2
Ultimate strength; fu,p = 470 N/mm 2

Stud anchor details


Number of anchors; Nsc = 28
Anchor length; hsc = 100 mm
Anchor diameter; dsc = 19 mm
Anchor pitch; p1,sc = 100 mm
Anchor gauge; p2,sc = 100 mm
Ultimate strength; fu,sc = 450 N/mm 2

Rebar details
Number of bar; Nbar = 4
Bar length; l = 750 mm
Bar diameter; d0,bar = 20 mm
Mandrel diameter; m = 250 mm
Yield strength; fy,bar = 500 N/mm 2
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 7
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

50

50
Min rebar length 480 mm
Min mandrel diameter 210 mm 350
50
30 162.5
100
100
100
925

825
100
100
100
162.5
50
100
25

75

75
100
100
100
Shear Stud Arrangement Check
Shear stud resistance
Mean compressive strength of concrete; fcm = fck + 8MPa = 40 N/mm 2
Secant modulus of concrete; Ecm = 22  (fcm / (10  1MPa))0.3  1GPa = 33.35 GPa
Area of anchor; Asc = 284 mm 2
Shear resistance of anchor; PRd,stud = 0.8  fu,sc  Asc / V = 81.66 kN
Alpha factor for stud length; =1=1
Stud resistance in concrete; PRd,conc = 0.29    dsc2  (fck  Ecm)1/2 / V = 86.51 kN
Single shear stud resistance; PRd = Min(PRd,stud, PRd,conc) = 81.66 kN
Shear stud group resistance; PRd,group = Nsc  PRd = 2286.38 kN
Utilisation; VEd / PRd,group = 0.416
Horizontal positional deviation
Horizontal deviation; phori = 35 mm
Depth of stud group; dsc,group = 600 mm
Breadth of stud group; bsc,group = 300 mm
Moment due to eccentricity; MT = VEd  phori = 33.25 kNm
Inertia of stud group x-axis; IX = 1120000 mm 2
Inertia of stud group y-axis; IY = 350000 mm 2
Polar moment of stud group; Ip = IX + IY = 1470000 mm 2
Stud radial distance; r = 335.41 mm
Shear in extreme stud due to moment; Vm = MT  r / Ip = 7.59 kN
Horizontal shear component; Vm,hori = Vm  dsc,group / (2  r) = 6.79 kN
Vertical shear component; Vm,vert = Vm  bsc,group / (2  r) = 3.39 kN
Max. shear in corner stud; Vm,max = ((VEd / Nsc + Vm,vert)2 + Vm,hori2)1/2 = 37.93 kN
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 8
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Utilisation; Vm,max / PRd = 0.465


Additional rotational deviation
Rotational deviation; protate = 1 in 10
Angle to outermost stud;  = atan(bsc,group / dsc,group) = 26.57
Additional angle from deviation;  = atan(1 / protate) = 5.71
Horizontal shear component; Vm,hori = Vm  cos( + ) = 6.41 kN
Vertical shear component; Vm,vert = Vm  sin( + ) = 4.05 kN
Max. shear in corner stud; Vm,rotate = ((VEd / Nsc + Vm,vert)2 + Vm,hori2)1/2 = 38.52 kN
Utilisation; Vm,rotate / PRd = 0.472
PASS - Shear stud resistance greater than design force

Reinforcement Arrangement and Size Check


Tension-compression couple
Nominal gap to face of the wall; gapnom = bgap + phori = 65 mm
Maximum gap to face of the wall; gapmax = bgap + 2  phori = 100 mm
Maximum eccentricity of beam; ep = tp + pinset + e2b + gapmax + (n2,fp - 1)  p2,fp / 2 = 179.2 mm
Bending moment due to eccentricity; Mp = VEd  ep = 170.24 kNm
Depth to rebar from top of fin plate; dbar = Max(e1,bar - dfp, 0 mm) = 0 mm
Required area of fin plate to resist thrust; Afp,couple = 600.87 mm 2
Depth of fin plate to resist thrust; dfp,c = Afp,couple / tfp = 37.55 mm
Lever arm for compression couple; lcouple = hfp - dbar - dfp,c / 2 = 821.22 mm
Tension-compression couple design force; Fcouple = Mp / lcouple = 207.3 kN
Confirmation of bar size for shear
Rebar area; Arebar = 314.16 mm 2
Tension resistance of rebar; Ft,Rd1 = Arebar  fy,bar / s,1 = 136.59 kN
Shear carried by rebar; V = VEd / Nbar  Nbar  Arebar / (Nsc  Asc + Nbar  Arebar) = 32.46 kN
Reduced resistance of rebar; Ft,Rd,red = (Ft,Rd12 - 3  V2)1/2 = 124.49 kN
Design tension for reinforcement; Ft,Ed1 = Fcouple  (p2,bar / 2 + phori) / p2,bar = 124.38 kN
Utilisation; Ft,Ed1 / Ft,Rd,red = 0.999
Confirmation of bar size for tying
Rebar area; Arebar = 314.16 mm 2
Tension resistance of rebar; Ft,Rd2 = Arebar  fy,bar / s,2 = 157.08 kN
Design tension for reinforcement; Ft,Ed2 = FEd/2  (p2,bar / 2 + phori) / p2,bar = 15 kN
Utilisation; Ft,Ed2 / Ft,Rd2 = 0.095
PASS - Rebar resistance greater than design force

Reinforcement Length Check


Concrete bond strength
Concrete mean tensile strength; fctm = 0.3  (fck / 1MPa)2/3  1MPa = 3.02 N/mm 2
Concrete axial tensile 5% strength; fctk,0.05 = 0.7  fctm = 2.12 N/mm 2
Concrete tensile alpha factor; ct = 1.00
Concrete tensile strength for shear; fctd1 = ct  fctk,0.05 / c,1 = 1.41 N/mm 2
Concrete tensile strength for tying; fctd2 = ct  fctk,0.05 / c,2 = 1.76 N/mm 2
Bond strength factors; 1 = 0.7
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 9
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

2 = 1.0
Concrete bond strength for shear; fbd1 = 2.25  1  2  fctd1 = 2.22 N/mm 2
Concrete bond strength for tying; fbd2 = 2.25  1  2  fctd2 = 2.78 N/mm 2
Required bond length
Tension resistance of rebar for shear; Ft,Rd1 = Arebar  fy,bar / s,1 = 136.59 kN
Tension resistance of rebar for tying; Ft,Rd2 = Arebar  fy,bar / s,2 = 157.08 kN
Basic bond length for shear; lb,req1 = Ft,Rd1 / (fbd1  pi(1)  d0,bar) = 978.1 mm
Basic bond length for tying; lb,req2 = Ft,Rd2 / (fbd2  pi(1)  d0,bar) = 899.9 mm
Overall basic bond length; lb,req = Max(lb,req1, lb,req2) = 978.1 mm
Minimum bond length; lb,min = Max(0.3  lb,req, 10  d0,bar, 100 mm) = 293.4 mm
Distance between rebars; a = 330 mm
Cover distance of rebar; cd = a / 2 = 165 mm
Bond length factors; 1 = 0.7
2 = Max(0.7, 1 - 0.15  (cd - 3  d0,bar) / d0,bar) = 0.7
3 = 1.0
4 = 1.0
5 = 1.0
Required anchorage length; lb = Max(1  2  3  4  5  lb,req, lb,min) = 479.3 mm
Geometry of bar bend
Considering Shear design force as critical
Concrete alpha factor; cc = 0.85
Distance between bar centres; ab = 350 mm
Concrete bearing strength for shear; fcd1 = cc  fck / c,1 = 18.13 N/mm 2
Concrete bearing strength for tying; fcd2 = cc  fck / c,2 = 22.67 N/mm 2
Minimum mandrel diameter; m,min = Ft,Rd1  (1 / ab + 1 / (2  d0,bar)) / fcd1 = 209.8 mm

Embedded Plate Bending Check


Bending resistance of plate
Eccentricity of fin plate; e = phori = 35 mm
Lever arm of reinforcement; m = (p2,bar - tfp - 2  0.8  sw,fp) / 2 = 159 mm
Lever arm from plate edge; n = Min(e2,bar, 1.25  m) = 50 mm
Effective length corner yielding; leff,nc1 = 2  m + 0.625  e2,bar + e1,bar = 399.2 mm
Effective length circular yielding; leff,cp = 2  pi(1)  m = 999 mm
Effective length side yielding; leff,nc2 = 4  m + 1.25  e2,bar = 698.5 mm
Minimum effective length; leff = Min(leff,nc1, leff,cp, leff,nc2) = 399.2 mm
Fin plate eccentricity alpha factor;  = n / (n + p2,bar) = 0.13
Eccentricity of rebar; ew = d0,bar / 4 = 5 mm
Mode 2 failure for shear force
Moment resistance of plate; Mpl,Rd1 = 0.25  leff  tp2  fy,p / M0 = 21.52 kNm
Mode 2 failure on farside eccentricity; FT,2,Rd,A1 = (Mpl,Rd1 +   n  Ft,Rd1) / (n + m + e) = 91.7 kN
Mode 2 failure on nearside eccentricity; FT,2,Rd,B1 = (Mpl,Rd1 + n  Ft,Rd1) / (n + m - e) = 162.94 kN
Overall mode 2 failure; FT,2,Rd1 = FT,2,Rd,A1 + FT,2,Rd,B1 = 254.64 kN
Utilisation; Fcouple / FT,2,Rd1 = 0.814
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 10
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Mode 1 failure for shear force


Mode 1 failure on farside eccentricity; FT,1,Rd,A1 = (4  n - ew)  Mpl,Rd1 / (2  n  (m - e) - ew  ((m - e) + n)) =
363.99 kN
Mode 1 failure on nearside eccentricity; FT,1,Rd,B1 = (4  n - ew)  Mpl,Rd1 / (2  n  (m + e) - ew  ((m + e) + n)) =
230.85 kN
Overall mode 1 failure; FT,1,Rd1 = FT,1,Rd,A1 + FT,1,Rd,B1 = 594.84 kN
Utilisation; Fcouple / FT,1,Rd1 = 0.348
Bending moment at face for shear force
Maximum design moment; Mfp,max1 = Max(Ft,Rd1  (m - e),   Ft,Rd1  (m + e)) = 16.94 kNm
Utilisation; Mfp,max1 / Mpl,Rd1 = 0.787
Mode 2 failure for tying force
Moment resistance of plate; Mpl,Rd2 = 0.25  leff  tp2  fu,p / M,u = 26.65 kNm
Mode 2 failure on farside eccentricity; FT,2,Rd,A2 = (Mpl,Rd2 +   n  Ft,Rd2) / (n + m + e) = 113.26 kN
Mode 2 failure on nearside eccentricity; FT,2,Rd,B2 = (Mpl,Rd2 + n  Ft,Rd2) / (n + m - e) = 198.32 kN
Overall mode 2 failure; FT,2,Rd2 = FT,2,Rd,A2 + FT,2,Rd,B2 = 311.59 kN
Utilisation; FEd / FT,2,Rd2 = 0.160
Mode 1 failure for tying force
Mode 1 failure on farside eccentricity; FT,1,Rd,A2 = (4  n - ew)  Mpl,Rd2 / (2  n  (m - e) - ew  ((m - e) + n)) =
450.79 kN
Mode 1 failure on nearside eccentricity; FT,1,Rd,B2 = (4  n - ew)  Mpl,Rd2 / (2  n  (m + e) - ew  ((m + e) + n)) =
285.9 kN
Overall mode 1 failure; FT,1,Rd2 = FT,1,Rd,A2 + FT,1,Rd,B2 = 736.69 kN
Utilisation; FEd / FT,1,Rd2 = 0.068
Bending moment at face for tying force
Maximum design moment; Mfp,max2 = Max(Ft,Rd2  (m - e),   Ft,Rd2  (m + e)) = 19.48 kNm
Utilisation; Mfp,max2 / Mpl,Rd2 = 0.731
PASS - Plate bending resistance is greater than design force

Embedded Plate and Fin Plate Bending Check


Bending moment on fin plate
Eccentricity of fin plate; e = ep - tp = 154.2 mm
Reduced moment on fin plate; M = VEd  e = 146.49 kNm
Elastic modulus of fin plate; Z = tfp  hfp2 / 6 = 1881600 mm 3
Bending resistance of fin plate; MRd = fy,fp  Z / M0 = 649.15 kNm
Utilisation; M / MRd = 0.226
Tying force on Tee-section
Tee section area; ATee = p2,bar  tp + bfp  tfp = 11204 mm 2
Plastic centroid of Tee section; zTee = ATee/2 / p2,bar = 16 mm
Plastic modulus of Tee section; ZTee = ATee  zTee / 4 + (tp - zTee)2  p2,bar / 2 + (bfp / 2 + tp - zTee)  bfp  tfp =
269317 mm 3
Bending resistance of Tee section; MRd,Tee = Min(fu,p, fu,fp)  ZTee / M,u = 115.07 kNm
Design moment on Tee section; MEd,Tee = FEd  p1,bar / 8 = 5.16 kNm
Utilisation; MEd,Tee / MRd,Tee = 0.045
Bearing resistance of concrete
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 11
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Vertical dimension of bearing; d = dfp,c + 5  tp = 162.6 mm


Horizontal dimension of bearing; b = tfp + 2  sw,fp + 5  tp = 161 mm
Concrete bearing resistance; FRd,u = d  b  fcd1 = 474.57 kN
Utilisation; Fcouple / FRd,u = 0.437
PASS - Embed and fin plate bending resistance is greater than design force

Reinforcement Weld Check


Correlation factor; p = 0.90
Weld strength; fv,wd = fu,p / (3) / (p  M,u) = 274.1 N/mm 2
Minimum throat thickness; amin = Ft,Rd2 / (2  fv,wd    d0,bar) = 4.6 mm
Actual throat thickness; a = 0.7  sw,p = 42 mm
Utilisation; amin / a = 0.109
PASS - Weld resistance greater than design force

Wall Punching Shear Check


915

20mm  bars 450


at 200 c/c's

925
20mm  bars
at 200 c/c's

30
1000

Shear stress on plate perimeter due to moment


Plate parallel dimension; c1 = 925 mm
Plate perpendicular dimension; c2 = 450 mm
Effective wall depth; d = twall - cwall - d0,r1 - d0,r2/2 - tp - pinset = 915 mm
Rectangular k factor; k = 0.71
Plastic moment of plate shear perimeter; W 0 = c1  (c1 / 2 + c2) = 844063 mm 2
Shear stress due to moment; Ed1 = k  Mp / (W 0  d) = 0.16 N/mm 2
Concrete reduction factor;  = 0.6  (1 - fck / 250MPa) = 0.52
Maximum punching shear resistance; Rd,max1 = 0.5    fcd1 = 4.74 N/mm 2
Utilisation; Ed1 / Rd,max1 = 0.033
Shear stress on plate perimeter due to tying
Plate perimeter; u0 = (hp + bp)  2 = 2750 mm
Project Job Ref.
J110_Concourse Floor
Section Sheet no./rev.
Detail 61 12
Calc. by Date Chk'd by Date App'd by Date
A 3/25/2024

Shear stress due to tying; Ed2 = FEd / (u0  d) = 0.02 N/mm 2


Maximum punching shear resistance; Rd,max2 = 0.5    fcd2 = 5.93 N/mm 2
Utilisation; Ed2 / Rd,max2 = 0.003
Shear stress on control perimeter due to moment
Basic control section C-factor; CRd,c1 = 0.18 / c,1 = 0.12
Basic control section k-factor; ku1 = Min(1 + (200mm / d), 2.0) = 1.47
Vertical reinforcement area in wall; Aly =   d0,r22 / 4 = 314 mm 2
Horizontal reinforcement area in wall; Alz =   d0,r12 / 4 = 314 mm 2
Vertical reinforcement ratio in wall; ly = Aly / (twall  p1,r2) = 0.00157
Horizontal reinforcement ratio in wall; lz = Alz / (twall  p1,r1) = 0.00157
Overall reinforcement ratio; l = Min((ly  lz), 0.02) = 0.00157
Control perimeter shear resistance; Rd,cp1 = CRd,c1  ku1  (100  l  fck/1MPa)1/3  1MPa = 0.3 N/mm 2
Minimum shear resistance; min = 0.035  ku13/2  (fck/1MPa)  1MPa = 0.35 N/mm 2
Basic shear resistance control perimeter; Rd,c1 = Max(Rd,cp1, min) = 0.35 N/mm 2
Plastic moment of control shear perimeter; W 1 = c12 / 2 + c1  c2 + 4  c2  d + 16  d2 + 2    d  c1 = 2.107 mm 2
Design shear stress control perimeter; Ed1,cont = k  Mp / (W 1  d) = 0.01 N/mm 2
Utilisation; Ed1,cont / Rd,c1 = 0.018
Shear stress on control perimeter due to tying
Basic control section C-factor; CRd,c2 = 0.18 / c,2 = 0.15
Control perimeter shear resistance; Rd,cp2 = CRd,c2  ku1  (100  l  fck/1MPa)1/3  1MPa = 0.38 N/mm 2
Basic shear resistance control perimeter; Rd,c2 = Max(Rd,cp2, min) = 0.38 N/mm 2
Basic control perimeter; u1 = u0 + 2    (2  d) = 14248.2 mm
Design shear stress control perimeter; Ed2,cont = FEd / (u1  d) = 0 N/mm 2
Utilisation; Ed2,cont / Rd,c2 = 0.010
PASS - Wall shear resistance greater than design force
;