Custody Transfer Static Mixer Metric Units

The document is a Custody Transfer Static Mixer Sizing Questionnaire that collects essential process and mechanical data for sizing static mixers, including fluid properties, flow rates, and material specifications. It emphasizes compliance with ISO3171/API 8.2 standards, particularly regarding water content in oil, and requests specific information on injection and sample points. Completed questionnaires should be returned to various Statiflo representatives across the UK, Germany, USA, and Canada.

Uploaded by

Shiloh Tony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

Custody Transfer Static Mixer Metric Units

The document is a Custody Transfer Static Mixer Sizing Questionnaire that collects essential process and mechanical data for sizing static mixers, including fluid properties, flow rates, and material specifications. It emphasizes compliance with ISO3171/API 8.2 standards, particularly regarding water content in oil, and requests specific information on injection and sample points. Completed questionnaires should be returned to various Statiflo representatives across the UK, Germany, USA, and Canada.

Uploaded by

Shiloh Tony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

Issue 01

N#
Date
Custody Transfer Static Mixer Sizing Questionnaire Project Name
Quantity
Process Data Engineers Initials
Please Note - The ISO3171 / API 8.2 standards are only applicable when the water content of the oil is less than 10-20%.
COMPONENT MAIN FLOW
Fluid name
Physical State
Flowrate, Min / Norm / Max m3/hr m3/hr m3/hr
Viscosity, cP
Density, kg/m³
Pressure, Barg
Temperature, °C

A C1/C2 ratio of 0.9 to 1.0 is the industry standard and indicates very good dispersion. Yes
Would this be acceptable? No (Requirement shown below)
Alternative C1/C2 ratio required

Mechanical Data
Pipe Diameter, mm
Alternative Pipe Diameter, mm (If any)
Maximum Pressure drop, Barg
Injection Point(s) Yes / No*
Sample Point(s) Yes / No*
Other Connection Point(s) Yes / No*
End Connections / Specification
Housing Schedule

316L Stainless Steel Carbon Steel 304 Stainless Steel


Materials of Construction
Other (Please Specify)
Design Code
Operating / Design Temperature, °C
Operating / Design Pressure, Barg
Special Painting

Hydrotest MPI 10% Radiography 100% Radiography


Tests / NDE
Other (Please Specify)
Other Data

Brief Process Description with Flowsheet (if applicable)


* If injection and/or sample point(s) are required please sketch number, size and location

Please return completed Questionnaire to your local representative or:


Statiflo International Ltd Statiflo GmbH Statiflo Corp Statiflo Inc
Wood Street Auf der Voßwiese 2 75 South Church St, 6th floor, Pittsfield, MA 2175 Sheppard Ave E, Suite 203
Macclesfield, Cheshire SK11 6JQ, 51643 Gummersbach, 01201, Willowdale, Ontario M2J 1W8,
United Kingdom Germany USA Canada
Tel: +44 (0)1625 433100 Tel: +49 (0)2261 913570 Tel: +1 (413) 684-9911 Tel: +1 (416) 756-2406
Fax: +44 (0)1625 511376 Fax: +49 (0)2261 913580 Fax: +1 (413) 464-8239 Fax: +1 (416) 490-6937
E-mail: sales@[Link] E-mail: info@[Link] E-mail: sales@[Link] E-mail: sales@[Link]

©2014 Statiflo International Ltd


Issue 01

N#
Date
Custody Transfer Static Mixer Sizing Questionnaire Project Name
Quantity
Process Data Engineers Initials
Please Note - The ISO3171 / API 8.2 standards are only applicable when the water content of the oil is less than 10-20%.
COMPONENT MAIN FLOW
Fluid name
Physical State
Flowrate, Min / Norm / Max USgal/min USgal/min USgal/min
Viscosity, cP
Density, lb/ft³
Pressure, PSIG
Temperature, °F

A C1/C2 ratio of 0.9 to 1.0 is the industry standard and indicates very good dispersion. Yes
Would this be acceptable? No (Requirement shown below)
Alternative C1/C2 ratio required

Mechanical Data
Pipe Diameter, Inch
Alternative Pipe Diameter, Inch (If any)
Maximum Pressure drop, PSIG
Injection Point(s) Yes / No*
Sample Point(s) Yes / No*
Other Connection Point(s) Yes / No*
End Connections / Specification
Housing Schedule

316L Stainless Steel Carbon Steel 304 Stainless Steel


Materials of Construction
Other (Please Specify)
Design Code
Operating / Design Temperature, °F
Operating / Design Pressure, PSIG
Special Painting

Hydrotest MPI 10% Radiography 100% Radiography


Tests / NDE
Other (Please Specify)
Other Data

Brief Process Description with Flowsheet (if applicable)


* If injection and/or sample point(s) are required please sketch number, size and location

Please return completed Questionnaire to your local representative or:


Statiflo International Ltd Statiflo GmbH Statiflo Corp Statiflo Inc
Wood Street Auf der Voßwiese 2 75 South Church St, 6th floor, Pittsfield, MA 2175 Sheppard Ave E, Suite 203
Macclesfield, Cheshire SK11 6JQ, 51643 Gummersbach, 01201, Willowdale, Ontario M2J 1W8,
United Kingdom Germany USA Canada
Tel: +44 (0)1625 433100 Tel: +49 (0)2261 913570 Tel: +1 (413) 684-9911 Tel: +1 (416) 756-2406
Fax: +44 (0)1625 511376 Fax: +49 (0)2261 913580 Fax: +1 (413) 464-8239 Fax: +1 (416) 490-6937
E-mail: sales@[Link] E-mail: info@[Link] E-mail: sales@[Link] E-mail: sales@[Link]

©2014 Statiflo International Ltd

You might also like