You are on page 1of 11

1) DATA

SPAN = 5
MOMENT = 81 kN.m
SHEAR = 50 kN.m
leff. Factor(web buckling) = 1

2) CHOOSE INITIAL SECTION


λ (Assume) = 100 mm
h/tf (Assume) = 25
from table 10.9 fcr,b = 291.31 N/mm2
λlt = 0.926
αlt = 0.2
ɸlt = 1.005
χlt = 0.716 < 1
= Condition OK
fbd = 162.8 N/mm2
required section (Ze or Zp) = 497.5 x 103 mm3

3) SECTION DETAILS
D = 203 mm
B = 203 mm
Tf = 8.6 mm
Tw = 5.5 mm
Ry FROM CODE = 200 mm
= Section is increase
AREA = 2341 mm2
ry-manual calculate = 71.569 mm
ry min = 71.6 mm
b/tf = 23.6 < 9.4
= SECTION SEMI-COMPACT

4) LATERAL TORSIONAL BUCKLING


G = 76.9 x103 N/mm2
It = 96.861 x103 N/mm2
βf = 0.5
h = 194.4
Iw = 113.308 x109 mm6
Mcr = 124.5 kN
approximate Mcr Eqn
KL/R = 69.86
h/tf = 23.60
Mcr = 115.1 kN
λlt = 0.9
αlt = 0.21
ɸlt = 0.96
χlt = 0.75 < 1
= Condition OK
fbd = 170 N/mm2
Md = 65.60 kN.m
load moment condition = 65.60 > 81.0
= Moment Capacity Not OK

5) SHEAR CAPACITY
Vd = 146.5 kN
= 146.5 > 50
0.6*Vd = 87.90 > 50
= Shear is ok

6) WEB BUCKLING CHECK


Ab=(b1+n1)*tw = 1101.375 mm2
b1 = 98.75 mm
n1*D/2 = 101.5 mm
I=b.tw3/12 = 1369.13 mm4
A = 543.1 mm2
rmin = 1.59 mm
web depth = 185.80
λ = 117.0
fcd from table 9c = 167 N/mm2
Strength of section Against
web buckling = 183.9 kN
= 183.9 > 50
= Web buckling safe

7) check for web bearing


Fw=(b1+n2).tw.fy/ɣmo = 177.2 kN
n2 = 43 mm
condition = 177.2 > 50
= web bearing is Safe
1)
SECTION DETAILS
D = 203 mm
B = 203 mm
Tf = 8.6 mm
Tw = 5.5 mm
Fy = 250 MPa

2) PL.MODULUS Z-Z AXIS


d = 185.8 mm
Y2 = 101.5 mm
A1=(D/2)*tw = 558.25 mm2
A2=(B-tw)*Tf = 1698.5 mm2
y1 bar=D/4 = 50.75 mm

y2 bar=(D/2-Tf/2) = 97.2 mm
Zp = 2(A1.y1+A2.y2)
Zpz = 386.85 x 103 mm3
Izz = 3222.57 x 104mm4

1.27% in Izz = 4092.67 x 104 mm4


Zez = 403.2 x 103 mm3
Shape Factor = 0.96

3) PL.MODULUS Y-Y AXIS


B/2 = 101.5 mm
A3=(D-2T).t/2 = 510.95 mm2
A4=2(B/2)T = 1745.8 mm2
y3 bar = t/4 = 1.375 mm
y4 bar = B/4 = 50.75 mm
Zpy = 178.604 x 103 mm3
Iyy = 1199.3 x 104 mm4
Zey = 118.2 x 103 mm3
Shape Factor = 1.51
MOMENT CARRYING CAPACITY
1) DATA
L = 5m
SECTION DETAILS
H = 203 mm
B = 100 mm
Tf = 8.6 mm
Tw = 5.5 mm

2) GENERAL CALCULATIONS
d = 174 mm
Izz = 1588.77 x 104mm4
Iyy = 2017.74 x 104mm4
Ze = 198.8 x 103 mm3
Zp = 214.65 x 103 mm3

3) laterally unsupported beam


Mcr= formula is800: = pg no:54 clause:8.2.2.1
G = 76.9 x 103 N/mm2
It = 0.53 x 105 mm4
KL = 5000 mm
hf = 194.4 mm
βf = 0.5
Iw = 1.9 x 1011 mm6
Mcr = 1.74E+08
Mcr = 174 kN.m

4) PROPERTIES OF SECTION
b/tf = 11.628 < 9.4
= Section is Semi Compact Section is Semi Compact

5) MOMENT CARRYING
λLT = 0.555
αlt = 0.21
ɸlt = 0.69
Χlt = 0.91 < 1
fbd = 206.00 N/mm2
Md = 44 kN
MOMENT CARRYING
CAPACITY OF SECTION = 44 kN
P= UDL 25 KN
MOMENT WL2/8 = 78.125 kN
Section Failed
1)
SECTION DETAILS
D = 203 mm
B = 100 mm
Tf = 8.6 mm
Tw = 5.5 mm
Fy = 250 MPa

2) PL.MODULUS Z-Z AXIS


d = 185.8 mm
Y2 = 101.5 mm
A1=(D/2)*tw = 558.25 mm2
A2=(B-tw)*Tf = 812.7 mm2
y1 bar=D/4 = 50.75 mm
y2 bar=(D/2-Tf/2)
�=(−𝑏±√(𝑏^2= 97.2 mm
−4𝑎𝑐))/2𝑎 =
Zp 2(A1.y1+A2.y2)
Zpz = 214.65 x 103 mm3
Izz = 1588.77 x 104mm4
1.27% in Izz = 2017.74 x 104 mm4
Zez = 198.8 x 103 mm3
Shape Factor = 1.08

3) PL.MODULUS Y-Y AXIS


Semi Compact B/2 = 50 mm
A3=(D-2T).t/2 = 510.95 mm2
A4=2(B/2)T = 860 mm2
y3 bar = t/4 = 1.375 mm
y4 bar = B/4 = 25 mm
Zpy = 44.405 x 103 mm3
Iyy = 143.6 x 104 mm4
Zey = 28.7 x 103 mm3
Shape Factor = 1.55
LSJ

1) DATA
LOAD = 1000 kN
height of column = 12 m
fy = 230 Mpa
bracing connection
poit location L1 ly = 6
L2 lz = 9
utilization of section
kz = 1.2
ky = 1

2)
avoid local buckling = d/t < 42ε
ε = 1.04
limiting width d = 44 t

3) Trial section
P = 1000 kN
Assume fcd = 172.5 or 250
Area of C/S = 4000 mm 2

utilization of section
rz/ry = 1.8
b = 24.3 t
Area provided = 136.2
thickness of plate = 5.4 mm
input
dia = 20 mm
grade = 10.9

output
tension capacity =
shear capacity =

tension capacit
dia 4.6
12 35
16 45
20 49
24 53
30 56
36 65
tension capacity shear capacity
8.8 10.9 4.6 8.8 10.9
43 55 43 55 112
52 61 53 67 125
59 70 63 72 140
64 80 73 78 149
71 89.6 83 84 170
85 97 92 110 192

You might also like