Professional Documents
Culture Documents
www.huawei.com
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 2
BSC6910 - A New-Generation Large-Capacity RNC
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 3
BSC6910 - Cabinet 1. Subrack: PARCb subracks are used. Boards are installed on
the front and rear sides of the backplane. One subrack
provides 28 slots. Subracks are powered independently.
(The BSC6900 cabinet is powered in a centralized manner.)
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 6
BSC6910 - Interconnection Between
Subracks
1. BSC6910 uses the switching board
SCUb of BSC6900. The
interconnection mode between
subracks is the same as the mode
adopted for the BSC6900.
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 7
BSC6910 - Subracks
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Appearance of the PEM
Functions of the PEM
Provides power supply, surge protection and filtering
Monitors the input power and input voltage of subrack
Monitors the status od air circuits and of surge protection circuits
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 9
BSC6910 - Slots
1. Each BSC6910 subrack provides 28 slots, among
which there are sixteen 2 x 10GE slots and ten 4 x
GE slots.
4 2. SCUb boards that used as the switching board are
inserted in slots 20 and 21 fixedly.
3. EOMUa boards are inserted in slots 10 to 13 of the
MPS subrack. Those fixed slots are different from
those of the BSC6900.
4. The rear board slot only provides the cable through
for optical fibers. The interface board needs to be
inserted in the rear subrack.
5. This is different in BSC6900. 10GE interface
boards, such as EXOUa, can use slots 16 to 19
and slots 22 to 25. Other interface boards can use
any slots in the rear half of the subrack.
6. Slots 8 and 9 of the MPS subrack are fixedly
configured with one pair of EGPUa boards, forming
1+1 redundancy for resource management of the
entire system.
7. Other EGPUa boards for service processing form a
1 Front board slot 10GE port resource pool. They can be inserted in any slots.
2 Backplane However, they are preferentially installed in the
GE port front half of the subrack because the rear half is
3 Rear board slot
reserved for interface boards.
4 switching board slot
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 10
BSC6910 - Boards
Physical Physical
Function Description Function Description
Board Board
OMU EOMUa Evolved OMU board GE Switch and
SCU SCUb
SAU ESAUa Evolved SAU board Control Board
UCUP EGPUa/EXPU GCK GCUa/GCGa General Clock Unit
GCUP a
Evolved General
RMP (EXPUa used IP transmission
Processing board GOUc/FG2c
GMCP only on 2G interface board
NASP networks) ATM transmission
AOUc/UOIc
Evolved 10GE INT interface board
INT EXOUa TDM Interface
interface board
Evolved Network POUc Unit(4 STM-1,
NIU ENIUa Channelized)
Intelligence Unit
* The SPU and DPU processing boards of BSC6900 is replaced by single processing board EGPU.
* RMP: Resource Management Processing, for managing resources
* GCUP: GSM CP and UP Processing, for processing GSM services
* UCUP: UMTS CP and UP Processing, for processing UMTS services
* EXPUa: used only on the GSM network, with the same specifications as EGPUa
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 11
BSC6910 EGPUa Board
DPUb
DPUe
EGPU boards in BSC6910 use for both control and
SPUa user plane which work in N+1 configuration.
Also the EGPU boards process both CS and PS
SPUb user data
For EGPU board, it automatically adjust the NodeB
DPUc or cell on the board. There is on requirement for
specify subsystem number while configuring NodeB
DPUd EGPUa
When it is used on the UMTS control plane, its
DPUf processing capability is equal to 6.4 times of the
processing capability of an SPUb board.
DPUg When it is used on the UMTS user plane, its
processing capability is equal to 2.5 times of the
XPUa
processing capability of a DPUe board.
XPUb
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 12
EGPU Processing capability
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 13
BSC6910 - EOMUa and ESAUa
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 14
EOMUa and ESAUa Board
Evolved Operation and Maintenance
2 Boards must be installed on BSC6910
One EOMUa board occupies 2 slots.
Its recommended that EOMUa boards be installed in a lot 10 and 12 of MPS.
Performs the configuration management, fault management, security management and
loading management functions for the system.
Enables LMT or M2000 users to perform operation and maintenance on the BSC6910 to
control the communication between the LMT or M2000 and the host boards of BSC6910
Evolved Service Aware Unit
ESAUa board collects and preprocesses the data reported by NEs. Then upload the data
to M2000
One ESAUa board occupies two slots. ESAUa boards can be installed in slots where the
SCUb, GCUa, and GCGa boards are not installed. It is recommended that the ESAUa
board be installed in slots 0 to 1
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 15
BSC6910 EXOUa Board
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 16
BSC6910 - System Capacity
BSC6900 BSC6910
Cabinet
Power
4,800 W + 4,800 W 7,100 W 7,100 W + 7,100 W
consumption
BHCA 64,000 K
BHCA 5,300 K BHCA 32,000 K
Iub throughput 120
UMTS Iub throughput 40 Gbit/s Iub throughput 60 Gbit/s
Gbit/s
Capacity NodeB 3,000 NodeB 5,000
NodeB 10,000
Cell 5,100 Cell 10,000
Cell 20,000
Two-cabinet configuration is
not supported. All IP: 24,000 TRXs,
Two-cabinet
GSM Specifications of a single 150,000 Erl
configuration is not
Capacity cabinet: Abis TDM+A IP: 10,000
supported.
All IPs: 8,192 TRXs, 45,000 TRXs, 62,500 Erl
Erl
*7,100 W is a software limitation for BSC6910 to lower the impact to equipment room.
BSC6910 heat dissipation system has the capability to support 6000 W per subrack, and is ready for future evolution.
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 17
BSC6910 - Board Resource Pool
In BSC6910, a pair of EGPUa boards are
configured for resource management
processing (RMP) using 1+1 backup.
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 18
BSC6910 - UCUP Resource Pool and
Resource Sharing
Resource Sharing (UMTS Only)
1. On UMTS networks, the traffic model changes frequently,
which greatly affects the processing capability of the
CP/UP. BSC6910 supports manual and automatic
capability sharing between the CP and UP.
2. When the EGPUa board is used for UCUP, the multiple
subsystems on the board are used for CP or UP
processing. The CP and UP are dynamically adjusted by
performing the following operations: Stop some
subsystems, then restart these subsystems and enable
them to use new software functions, and add them to a
new resource pool.
CP CP
UP UP
1. All CP subsystems in RNC form a CP POOL.
2. All UP subsystems in RNC form a UP POOL.
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 19
BSC6910 - NodeB/Cell Resource
Management Sharing
Resource Sharing (UMTS Only)
1. In initial configuration, the system 2. When the system is running, adding a new board or the
automatically selects the processing emergence of a hotspot cell or hotspot site will lead to load
subsystems of NodeBs and cells. imbalance between subsystems. The BSC6910 can monitor
the status of subsystems and automatically adjust load.
* Introduction to the Automatic NodeB and Cell Allocation in the RNC Feature describes this feature.
* This feature is only applied in UMTS networks. This feature is not supported by GSM networks because the traffic model on GSM
networks is relatively table.
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 20
BSC6910 - UMTS Dimensioning
Principles
Functional boards of BSC6910 and BSC6900 are compared as follows:
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 21
BSC6910 - UMTS Dimensioning
Principles
Board Used for Specification Memo
PS Throughput 2,000 Mbit/s or
10,050 CS Erlang, 1,400 cells, PS throughput is calculated based on
UP Only
28,000 active users, unlimited on- the UL/DL rate of 64/384 kbit/s.
line users
EGPUa
1.668 KK BHCA,
Busy hour call attempts (BHCAs) are
700 NodeBs and 1,400 cells,
CP Only calculated based on Huawei
36,000 active users,
smartphone traffic model.
70,000 on-line users
1. The UMTS dimensioning principles of BSC6910 is basically the same as BSC6900. The only
difference is that the dimension of an SPUb board and DPUe board is replaced by the
dimension of a EGPUa board.
2. The number of EGPUa boards on the CP and UP are calculated separately based on the
capability requirements of the network on the CP and UP. The following formula is used:
3. Total number of EGPUa boards = Number of EGPUa boards used on the CP + Number of
EGPUa boards used on the UP + One backup EGPUa board at least + Two EGPUa boards
used for resource management
4. The CPU overload threshold of the BSC6910 is 70%
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 22
BSC6910 - Hardware Capacity License
The license control mechanism of BSC6910 is basically the same as BSC6900, including
feature licenses, system capacity licenses, and hardware licenses.
The feature license functions based on features and is basically the same as that of the
BSC6900. (For details about the features supported by the BSC6910 and features not
supported by the BSC6910 but supported by the BSC6900, see the Feature List in RAN15.0.)
The system capacity license has the same dimension as that of BSC6900. By default, 1 CS
Erlang is equal to 64 kbit/s PS throughput in the BSC6900. In the BSC6910, 1 CS Erlang is
equal to 24.4 kbit/s PS throughput. The conversion coefficient in the BSC6910 is commonly
used. If only the PS traffic capacity is for sales, the conversion coefficient customized for sales
is used.
The new EGPUa board has a larger capacity and can be shared by the GSM and UMTS. A
hardware license is required to control the board capacity. The hardware license is similar to
that of the DPUe board of the BSC6900. The major difference is that the DPUe board has 335
Mbit/s capacity when the hardware license is not activated, while the EGPUa board has no
capacity if the hardware license is not activated. Hardware licenses include:
3G:
-Hardware capacity sold based on every 50 Mbit/s throughput on the RNC
-Hardware capacity sold based on every 1000 active users on the RNC (active users
refers to online users in the CELL_DCH state and CELL_FACH state.)
2G:
-Hardware capacity sold based on every TRX on the BSC
-Hardware capacity sold based on every PDCH on the BSC
Copyright 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 23
BSC6910 - Power Consumption
Calculation
Calculation Formula:
1. System power consumption = Pavg x Number of each type of boards + Pavg of fans)
2. Heat dissipation capability in the equipment room = System power consumption
3. Maximum subrack power consumption = 4,000 W, Maximum cabinet power consumption = 7,100 W
Concepts:
. Average power consumption (Pavg) is the estimated value in a typical operating environment. The
maximum power consumption mentioned in hardware description is obtained when all devices on
boards are full-loaded. This maximum power consumption cannot be obtained under the actual system
running conditions. Therefore, Pavg is provided for power consumption calculation.
. Maximum subrack power consumption is 4,000 W (including the power consumption of fans) which is
obtained when all slots of the subrack are configured with boards. It is recommended that power
distribution be configured as 4000 W per subrack. This can save power distribution adjustment upon
future capacity expansion.
. Maximum cabinet power consumption is 7,100 W which is the upper limit of the heat dissipation
capability in the equipment room and obtained based on survey and research. Therefore, the maximum
cabinet power consumption is not 12,000 W.
Page 24
The tools and features for BSC6900 operation and maintenance (O&M)
are also used for BSC6910 O&M. Besides, BSC6910 O&M is simplified
by sharing the UP and CP and automatically allocating NodeBs and cells.