Hardware Checking
DL Simulation : check RTWP between start and stop
DL simulate
If values are - 101 to -108 dBm mean RTWP is normal.
DL Simulate
If values more than -100 dBm and more than before and
after DL simulation mean RTWP are abnormal and hardware
have problem.
DL Simulate
If values more than -100 dBm and the values same with
before and after DL simulation mean RTWP are abnormal
and have interference.
DL Simulate
Page 1
DL Simulation
Page 2
Interference Checking
Block board
BLK BRD:CN=0,SRN=60,SN=0,BLKTP=IMMEDIATE;
Go to Monitor at Maintenance client of NodeB
Fill RRU Location and UL UARFCN
RRU Location
UL UARFCN
UL UARFCN
U850 : 4208 4232
U2100 : 9613 9663
Reference :
http://niviuk.free.fr/umts_band.ph
p
Page 3
RF Frequency Scanning
Page 4