ANALYSIS AND COMPARITIVE STUDY OF GUYED TOWER USING DIFFERENT

CODAL PROVISIONS
A mid - term
Presentation
submitted in fulfillment of the requirements for the Degree of
BACHELOR OF TECHNOLOGY
Under the supervision of
Mr. Kaushal Kumar
Assistant Professor (Grade II)
By
SARTHAK GUPTA [151618]
HIMANSHU SINGH [151658]

Department of Civil Engineering


JAYPEE UNIVERSITY OF INFORMATION TECHNOLOGY, WAKNAGHAT
October, 2018 1
NEED OF STUDY
 Many tower facilities are coming of age and the
problem of anchor shaft corrosion is now becoming
an industrial issue.
 To make the structure more durable against high
intensity winds and earthquake.
 To improve the communication system so as to serve
better during calamities and post-war conditions.
LITERATURE REVIEW
Authors and year Journal
SNo. Title Critical Observations
of publication Name

Bibitha K. Eldhose, Linear analysis IJERA This paper aims at


Harinarayanan S. Of guyed mast investigating the liner time
S. Usha subjected to wind, history and structural non
1.
(2014) ice and seismic linearity of the structure
loading. subjected to wind, ice and
earthquake loading.
G.G. Amiri Seismic Response of Elsevier Objective of this paper is to
G. Mcclure tall guyed Science consider the overall
2.
(1996) telecommunication Ltd. seismic sensitivity of tall
towers. guyed towers.
Harsha Jatwa Comparative study of IJIET Comparison and
Vivek Tiwari Indian and ASCE modification of Indian code
3. Sumit Pahwa codes provision for as compared to ASCE
(2014) design of standards.
transmission tower.
LITERATURE REVIEW (Contd.)
Authors and year of Journal
SNo. Title Critical Observations
publication Name

Craig M. Snyder Understanding and Sioux Falls This paper analyzes the
preventing Guyed Tower causes of anchor shaft
tower failure due to Specialists corrosion and gives the
4.
anchor shaft Inc. means of protecting it
corrosion against the catastrophic
effects of corrosion
SUMMARY OF LITERATURE REVIEW
 Corrosion of guyed tower anchors is fast becoming
an issue of critical importance.

 Indian code has to be updated in comparison to ASCE


provisions, as it is updating itself with time.

 Studying the effects of seismic forces.


OBJECTIVES
Based on the Literature review, following objectives are
determined:

 To determine modifications required as to make the


design structurally more sound and economical.
 Analyze the structure against High intensity winds and
earthquakes for better durability.
 To improve the communication system so as to serve
better during calamities and post-war conditions.
METHODOLOGY
Read different research Complete the Learn and Practice various
paper regarding guyed literature design tools in ANSYS
towers review software

Apply wind load, seismic


Design Guyed towers using
load and various other
different codal provisions
loads as per design code

Compare and analyze


results obtained by
applying different codes
WORK PROGRESS
• Studied various research papers along with
the completion of Introduction and literature
review.
WORK PLAN
Months
August September October November December
Activities
Material Procurement/Sample
collection or the likes
Experimental testing/analysis
or the likes
REFERENCES
• G.G. Amiri and G. McClure – Seismic Response of tall Guyed Telecommunication towers –
Department of civil engineering and applied mechanics, McGill University, Macdonald
Engineering builing, 817 Sherbrooke Street west, Montreal, Quebec, Canada H3A 2K6.
• Bibitha K Eldhose, Harinarayanan S, S.Usha- Linear Analysis of Guyed Mast Subjected to
Wind, Ice and Seismic Loading- Department of Civil Engineering, Sree Narayana Gurukulam
College of Engineering, Kerala, India.
• Harsha Jatwa(M.Tech Student, CED Alpine Institute of Technology Ujjain, M.P. India), Vivek
Tiwari(Asst. Professor, (CE-AMD), Shri. G.S. Institute of Technology & Science Indore M.P
,India), Sumit Pahwa(Head & Professor CED Alpine Institute of Technology Ujjain, M.P.India) -
Comparative Study of Indian and ASCE Codes Provision for Design of Transmission Tower.
• Craig M. Snyder - Understanding and Preventing Guyed Tower Failure Due to Anchor Shaft
Corrosion - Sioux Falls Tower Specialists, Inc. , AnchorGuard - Corrosion Control For Tower
Anchors, Sioux Falls, South Dakota
Thank you

You might also like