Aesthetic/ Depending on the building span, beam and column are often Able to be flushed with the wall, maximized and efficient use of Some part flushed with the wall and some don’t (where the
Architectural Aspect big in size, dimensional wise may not flushed with the wall, living space. A big selling point to architects. column is)
leaving exposed column or beam at the corner of the room
Remarks More efficient design for low rise structure due to minimum or Very efficient construction method for repetitive structure, shorter Commonly used for super high rise, > 50 storey high.
negligible lateral loads. construction time and lesser wastages especially when being
constructed using precast components.
LOAD TRANSFER PATH
HYBRID (FRAME + SHEAR WALL)
FRAME SYSTEM SHEAR WALL SYSTEM SYSTEM
Floor Slab + Non-Load Bearing Wall Floor Slab + Non-Load Bearing Wall Floor Slab + Non-Load Bearing Wall
Column Shear Wall or Load Bearing Wall Column + Shear Wall or Load Bearing Wall
Lateral load Lower resistance to lateral loads (earthquake or wind loads) Higher bending stiffness and thus better resistance to lateral Depending on the size and location of rigid center core, the
resistivity due to lower bending stiffness loads (earthquake and wind loads) bending stiffness is generally higher due to the need to resist
- Resists lateral load by flexural and buckling deformation of - resists lateral load by initiating the shear deformation high lateral forces.
column. - Depending on the magnitude of earthquake, the damages
can be smaller compared to frame system.
LATERAL LOAD RESISTIVITY
Often not flushed with the wall, Able to be flushed with the wall, Some part flushed with the wall and
leaving exposed column at the corner leaving clean room spaces some don’t (where the column is)
of the room
AESTHETIC/ARCHITECTURAL ASPECTCriteria for openings:
- The openings has to be within
the limits of production
capability.
- Asymmetric openings will
need to be designed so that it’s
structurally rigid. Unless it’s a
non-structural wall, like façade.
IJM IBS MANUFACTURING PROCESS
OUR PRODUCTION LINE & PRODUCTS
- Solid Wall
- Floor Slab
- Column
- Beam
- Toilet Pan
- Staircase
• WALL
• Max height for wall = 3.5-3.6m
• Max length for wall According to crane weight limitation on site (5t, 7t etc)
• Max wall thickness = 250mm
• SLAB
• Thickness = 70mm, 90mm
• Width = 2.4m
• Length or span According to crane weight limitation on site (5t, 7t etc)
Example of dimension:
1) 5ton
• Wall: 150mm (t) x 3m (h) x 4.15m (w)
• Slab: 70mm (t) x 2.4m (w) x 4m (l)
2) 7ton
• Wall: 150mm (t) x 3m (h) x 6.3m (w)
• Slab: 90mm (t) x 2.4m (w) x 6m (l)
Steel Area to Poundage
WALL
PROS
• Light
• 1 side of the wall is smooth, reducing touch up PROS
works (can be painted directly without the need • Can cater more weight this suitable for core walls,
for skim coating ) shafts, basement, etc
• Thinner than double wall which allows bigger • Can be casted in longer span/width and when done so,
room opening is much lighter than single solid wall of same dimension • Can be done on single solid wall and double
• A monolithic structure – eliminate structural framework wall
CONS and mechanical joints between panels, increase • To give aesthetic value to the surface of the wall
• Need mechanical joints efficiency and speed and less on site materials to • IJM IBS is not yet able to cast this type but it is
• Can only be casted up to certain length handle in planning
• • Water tight
THERE ARE POSSIBILITY TO DO
Need waterproofing solutions at joints
• Both surfaces of the panel achieve an off form finish THIS IN OUR FACTORY
IJM IBS CAN PRODUCE THIS CONS RECKLI, FORMLINER SUPPLIER
• Very thick and the thickness can be up to 500mm, THAT HELPING TO SHAPE
reducing room opening THESE SPECIAL WALL
SOLID WALL
SPECIFICATION
Max width: 6m
*due to length of storage rack
Wall Vertical Connections – Wire Loop
Wall Vertical Connections – Wire Loop
Wall Horizontal Connections – Steel Plate
DOWEL BAR
Diameter : 16mm, 20mm, 25mm
Number of bars :
• < 2.4m length = 2 (top) + 2 (bottom)
• > 2.4m length = 3 (top) + 3 (bottom)
CORRUGATED PIPE
Diameter : 50mm, 60mm
(size could be depending on type of wall,
length and load carried)
Wall & Slab Details (Facade Wall)
Example #1
Wall & Slab Details (Internal Wall)
Example #1
Horizontal Ties
Wall & Slab Details (Facade Wall)
Example #2
TYPE OF PRECAST FLOOR SLAB
LATTICE GIRDER SLAB SOLID HALF SLAB HOLLOW CORE SLAB
90mm
70mm
DIMENSION
• Thickness = 70mm, 90mm (based on our shuttering system)
• Width = 2.4m (due to transport regulation and limitation – width of trailer)
• Length or span = max. 3.4m (for 70mm thick, B8 mesh), can be bigger
with thicker slab and more reinforcement. According to crane weight
limitation on site (5t, 7t etc) as well.
REINFORCEMENT
Mesh
Diamater : 6mm, 7mm, 8mm, 9mm, 10mm, 11mm, 12mm
Yield strength : 500 Mpa
Rebar (T-bar)
Diameter : 10mm, 12mm etc
Yield Strength : 500 MPa
Slab Connections
• Some of the openings on the precast floor slab will be prepared in factory.
• Conduit and wiring works will be done onsite as it will be embedded inside in-situ topping up part of the floor slab.
TOILET PAN
SPECIFICATION
Thickness: 125mm (before topping up)
SPECIFICATION
Height: max. 3m
Width: 0.7-0.95m
BEAM
SPECIFICATION
Depth: max. 6m
Width: 90-150mm
*To flush the width with wall
Column
Beam
Staircase
Toilet Pan
Architectural Element
Prestressed Plank N/A Future Future Future Future
Lightweight Concrete
Future Future Future Future Future
Block
INDUSTRY
DIVISION
CONSTRUCTION
WHAT WE CAN PROVIDE TO THE EXTERNAL CLIENTS
2
MANUFACTURING 3
DELIVERY, ERECTION
& INSTALLATION
• Robotic assisted
• Accurate • Delivery is send based on project
erection sequence
• Flexible
• Faster construction period
• Seamless integration between BIM
and machine master control • Cleaner project site with lesser in-
software situ works