You are on page 1of 35

Knowledge Is Power SM

Apparatus Maintenance and Power Management


for Energy Delivery

Protection Test Equipment – The F Series


Mike O’Dowd – Asia Pacific Regional Sales Manager
Doble Engineering Company
PROPRIETARY INFORMATION

Doble Engineering Company ("Doble"), has full title, right and interest to all subject
matter contained in this presentation (”Proprietary Information") regardless of the
medium. You have been provided a copy of this Proprietary Information for private
reference purposes only. Doble's delivery to you of Doble Proprietary Information does
not constitute in any way whatsoever a license of any kind or vests any interest in
Doble's Proprietary Information (other than private reference use), including, without
limitation, the rights to copy, disseminate, distribute, transmit, display or perform in
public (or to third parties), reproduce, edit, translate or reformat. You, as recipient,
acknowledge and agree to these terms by your first viewing of this Proprietary
Information, you further acknowledge and agree that Doble shall not have an adequate
remedy at law in the event of your breach of the conditions hereunder, that Doble will
suffer irreparable damage and injury if you breach any of the conditions stated above,
and that such breach occurs, Doble, in addition to any other rights and remedies
available herein or otherwise, shall be entitled to seek an injunction to be issued by a
tribunal of competent jurisdiction restricting the recipient from committing or continuing
any breach of these conditions.
Overview

 Hardware
 Software
 Applications Engineers
 World Wide User Groups and Forums
Hardware Basics

 High Power output independent of other


source conditions
 Independent Controls of magnitude,
phase angle and frequency

Filters
Line Ampl. Feedback
Input Controls Output
Error
Ck.
Hardware - Switching Amplifiers

Sync
Rectifiers
37.5 VA
350 V
DC Inverter
75 VA Sync
Relay
Rectifiers
AC 37.5 VA Switch
Line matrix
Input for Output
Sync
Range 1*150 VA
Inverter Rectifiers
37.5 VA
Selection or
75 VA
2*75 VA
Sync
Rectifiers
37.5 VA

170 kHz
Hardware – Amplifiers Continued

 All specifications are for worst case


operating condition
 Source ratings are continuous
 Source ratings independent of
power factor of load
 Source ratings independent of
dynamic changes in load
characteristics
 Sources independent of each other
 Sources have AC/DC output
Hardware Continued

 F6150 Power System Simulator


 Three 150 VA Voltage/Low Current Sources
 Three 150 VA Current Sources
 Voltage Ranges – 75/150/300
 Current Ranges – 7.5/15/30
 High Accuracy ±0.02%
 Low Distortion ±0.02% THD
 Six 75 VA V/Low I Sources
 Six 75 VA I Sources
 8 Logic Inputs
 8 Logic Outputs (4x 0.5A & 4x 8A)
 Aux DC Source (Battery Simulator)
 Transducer Inputs (20mA / 10V)
F6150 Power System Simulator
F6150: Power

Convertible Voltage/Low Current Sources


 150 VA continuous
 195 VA for 1.5 seconds
Source Mode Range Comment
Voltage 50/60 Hz 75, 150, 300 Volts Continuous
Voltage DC 106, 212, 300 Volts Continuous
Current DC 1.41, 0.707, 0.354 A Continuous
Range Compliance
Current 50/60 Hz 0.5 A 300 Volts Continuous
1.0 A 150 Volts
2.0 A 75 Volts
Current 50/60 Hz 0.75 A 260 Volts 1.5 Seconds
1.5 A 130 Volts
3A 65 Volts
F6150: Power

Current Source
 150 VA continuous
 225 VA for 1.5 seconds

Source Range Compliance Comment


voltage
Current 7.5 A 20 V Continuous
50/60 Hz 15 A 10 V
30 A 5V
Current 15 A 15 V 1.5 Seconds
50/60 Hz 30 A 7.5 V
60 A 3.75 V
Current DC 5A 30 V Continuous
10 A 15 V
20 A 7.5 V
F6000: Power Output vs. Current

150

125
Output power

100

75
50

25
0
0 10 20 30
Output current
F6000: Power Output vs. Current

7.5 A Range: 150 VA

150

125
Output power

100

75
50

25
0
0 10 20 30
Output current
Compliance Voltage = 20 Volts
F6000: Power Output vs. Current

15 A Range: 150 VA

150

125
Output power

100

75
50

25
0
0 10 20 30
Output current
Compliance Voltage = 10 Volts
F6000: Power Output vs. Current

30 A Range: 150 VA

150

125
Output power

100

75
50

25
0
0 10 20 30
Output current
Compliance Voltage = 5 Volts
F6000: Power Output vs. Current

One Range 15 A 75 VA

150

125
Output power

100 VA
100

75
50

25 25 VA
0
0 10 20 30
Output current
Compliance Voltage = 5 Volts
Hardware Continued

 F6300 High Current Source


 Used with the F6150
 Additional 2x 450 VA / 90A
Sources
 3x 150VA @ 300V Voltages
and 3x 450 VA @ 90A Currents
 3x150VA @ 300V Voltages
and 9x 150VA @ 30A Currents
or 9x 225VA @ 60A Transient Currents
for 1.5 seconds
Hardware Continued

 F6050 Synchronizer

 Permits GPS Testing when access to


GPS signals is difficult
Hardware Continued
Hardware Continued
Doble Test Philosophy

 Verify the effectiveness of the setting not


simply check the characteristic
 Perform Transient based testing on
complete protection scheme to ensure
protection settings are correct for
application
 Use Dynamic testing to simulate system
conditions (State Simulation)
 Steady State tests to verify individual
elements are functioning.
Software

 ProTesT
 F6 TesT
 TransWin
 F6000 Control Panel
 Meter and Transducer
 PSCAD Relay
ProTesT Software

 Software system for protective relay


testing and equipment maintenance.
 SQL compliant Client server database
 Improve productivity
 Quality preventive maintenance
system
 Includes all elements of Doble Testing
Philosophy
ProTesT: Benefits

 Automate relay calibration tests


 Standardized test plans
 Increased productivity reduces testing
time.
 Test complete protection schemes
under realistic power system
conditions
 Create Standard Test Plan Libraries
with the “Settings”feature
 Highly customised testing capability
ProTesT Functions

 Steady-state protection testing


 Standardized tests using macros
 Automatic testing, results logging and
plotting
 Reports using Crystal Report engine
 Dynamic testing
 Power System State simulation (SSIMUL)
 Logic output control for event simulation
 Power System Model
ProTesT: Testing

 Transient testing
 COMTRADE data analysis and editing (T Plan)
 EMTP *.PL4 formats also supported
 End-to-End GPS satellite synchronized
scheme testing
 1 PPS signal for source synchronization
 State Simulation
 Transient testing
Software Continued

 F6 TesT
 Suite of powerful test templates
 All relay types available
 Impedance, Current, Voltage, Frequency
Differential, Directional
 State Simulation
 Ramp
 F6 TesT
Software Continued

 TransWin
 Transient Testing Software
 Permits the editing and playback of
COMTRADE Files
 Independent of ProTesT
 TRANSWIN
Software Continued

 F6000 Control Panel


 Manual Control of F6000
 Use to identify problems
 Integrated into ProTesT or use
separately
 F6000 Control Panel
Software Continued

 Meter and Transducer Testing


 Quick Testing of Transducers
 High Accuracy
 User Friendly interface
 Meter Test Studio
Software Continued

 PSCAD Relay
 Power System Modeling for the
Protection Test Engineer
 Graphical Interface
 Up to 36 Nodes PSCAD Relay
 Infinite Nodes for full version PSCAD
PSCAD Relay

 PSCAD Relay
Benefits

 Rugged Design – intended for field use


 Modular Redundant Design
- continue even after amplifier failure
 12 sources simultaneously
 Most power in a single instrument
 Extensible for more power with F6300
 Field Serviceable – no return to factory
 Repair and Calibration available in the
region
Benefits Cont’d

 Specifications are for worst case


- not ideal conditions
 Real Power for Power System
Simulations – Test complete
scheme not just a relay or element
 Flexible Software to test your way
 Static, Dynamic or Transient incl GPS
 True Power System Modelling with
PSCAD Relay
Why Doble Engineering?

 More Than 9000 Protection Test


Instruments Sold Worldwide
 Why?
 Quality
 Support – Conferences & Applications
 Creating equipment that meets
requirements & exceed expectations
 Reputation – The Industry Standard
Continuous Improvement

 We build good mouse traps


 But there is always a smarter mouse
We are ALWAYS working to IMPROVE