You are on page 1of 55

ELECTRICAL MENU Abnormal operation (A) 1/54

We will start with an IDG OIL LOW PRESSURE fault.

Let’s assume, you are the PNF. You are in flight and
everything is normal ...

Click on the forward arrow to activate the failure.

ELECTRICAL MENU Abnormal operation (A) 2/54


ELECTRICAL MENU Abnormal operation (A) 3/54
You hear the single chime and see
the Master Caution light.

No, to extinguish the Master Caution


light, push the Master Caution pb sw.

ELECTRICAL MENU Abnormal operation (A) 4/54


You hear the single chime and see
the Master Caution light.

No, to extinguish the Master Caution


light, push the Master Caution pb sw.

ELECTRICAL MENU Abnormal operation (A) 5/54


ELECTRICAL MENU Abnormal operation (A) 6/54
On the E/WD, read the title of the failure.

ELECTRICAL MENU Abnormal operation (A) 7/54


Observe the IDG
LO PR in amber on
the ECAM ELEC
page.

ELECTRICAL MENU Abnormal operation (A) 8/54


Observe IDG 1 FAULT light illuminated on
the ELEC panel.

ELECTRICAL MENU Abnormal operation (A) 9/54


These indications mean that the oil pressure in
IDG 1 is not sufficient. We can see from the blue
action line that we are required to disconnect the
IDG from the engine.

The PF will ask you to perform the ECAM


actions.
Perform ECAM action.

ELECTRICAL MENU Abnormal operation (A) 10/54


These indications mean that the oil pressure in
IDG 1 is not sufficient. We can see from the blue
action line that we are required to disconnect the
IDG from the engine.

The PF will ask you to perform the ECAM


actions.
No, raise IDG 1 guard.

ELECTRICAL MENU Abnormal operation (A) 11/54


These indications mean that the oil pressure in
IDG 1 is not sufficient. We can see from the blue
action line that we are required to disconnect the
IDG from the engine.

The PF will ask you to perform the ECAM


actions.
No, raise IDG 1 guard.

ELECTRICAL MENU Abnormal operation (A) 12/54


The pb sw guard is up, you can now disconnect
IDG 1.

Continue ECAM action.

ELECTRICAL MENU Abnormal operation (A) 13/54


The pb sw guard is up, you can now disconnect
IDG 1.

No, press IDG 1 pb sw.

ELECTRICAL MENU Abnormal operation (A) 14/54


The pb sw guard is up, you can now disconnect
IDG 1.

No, press IDG 1 pb sw.

ELECTRICAL MENU Abnormal operation (A) 15/54


CAUTION
Press IDG pb sw until GEN FAULT light
comes on but not more than 3 seconds to avoid
damage to the disengage solenoid.

ELECTRICAL MENU Abnormal operation (A) 16/54


As you can see, generator 2 has automatically
taken over and it is now supplying the entire
electrical network.

ELECTRICAL MENU Abnormal operation (A) 17/54


On the ECAM
ELEC page, an amber
DISC has replaced
the previous LO PR
meaning that IDG 1 is
now disconnected.

ELECTRICAL MENU Abnormal operation (A) 18/54


The IDG number is
in white to indicate
that engine 1 is still
running.

ELECTRICAL MENU Abnormal operation (A) 19/54


ELECTRICAL MENU Abnormal operation (A) 20/54
ELECTRICAL MENU Abnormal operation (A) 21/54
ELECTRICAL MENU Abnormal operation (A) 22/54
ELECTRICAL MENU Abnormal operation (A) 23/54
Let's look at GEN 1 indications for a moment.

•GEN in amber means


generator 1 has abnormal
parameters
•1 in white means engine 1 is
still running
•0% load in green means that
the load is still within the
normal range
•0 volts in amber means that
the voltage is outside the
normal range
•Amber “X”s means that
there is no frequency sensed

ELECTRICAL MENU Abnormal operation (A) 24/54


FAULT amber illuminated in the GEN 1 pb sw
means GEN 1 is not supplying the system.

ELECTRICAL MENU Abnormal operation (A) 25/54


Alongside the GEN 1 box, a white GALLEY
SHED indication has appeared meaning that
the system has automatically shed galley
equipment to decrease the load on the
remaining generator.

ELECTRICAL MENU Abnormal operation (A) 26/54


After review and confirmation from the PF...

Clear ELEC.

ELECTRICAL MENU Abnormal operation (A) 27/54


After review and confirmation from the PF...

No, press either CLR key.

ELECTRICAL MENU Abnormal operation (A) 28/54


After review and confirmation from the PF...

No, press either CLR key.

ELECTRICAL MENU Abnormal operation (A) 29/54


The STATUS page is displayed for review.

A green message advises us that the APU


generator is available up to FL 390, should we want
to use the APU as a backup.

ELECTRICAL MENU Abnormal operation (A) 30/54


You can see, in the INOP SYS column, that GEN 1
and the MAIN GALLEY are now inoperative.

After review and confirmation from the PF...

Clear STATUS.

ELECTRICAL MENU Abnormal operation (A) 31/54


You can see, in the INOP SYS column, that GEN 1
and the MAIN GALLEY are now inoperative.

After review and confirmation from the PF...

No, press the STS key or either CLR key.

ELECTRICAL MENU Abnormal operation (A) 32/54


You can see, in the INOP SYS column, that GEN 1
and the MAIN GALLEY are now inoperative.

After review and confirmation from the PF...

No, press the STS key or either CLR key.

ELECTRICAL MENU Abnormal operation (A) 33/54


ECAM action completed.

ELECTRICAL MENU Abnormal operation (A) 34/54


You have studied an IDG oil low pressure.

We will now see a GEN 2 OVERLOAD fault.

Let’s assume we are in flight with no previous faults.

Click on the forward arrow to activate the failure.

ELECTRICAL MENU Abnormal operation (A) 35/54


ELECTRICAL MENU Abnormal operation (A) 36/54
You hear the single chime and see the Master
Caution light .

No, to extinguish the Master Caution light, push the


Master Caution pb sw.

ELECTRICAL MENU Abnormal operation (A) 37/54


You hear the single chime and see the Master
Caution light .

No, to extinguish the Master Caution light, push the


Master Caution pb sw.

ELECTRICAL MENU Abnormal operation (A) 38/54


ELECTRICAL MENU Abnormal operation (A) 39/54
On the E/WD, read the title of the failure.

ELECTRICAL MENU Abnormal operation (A) 40/54


Observe:
•GEN and load indications in amber on the
ECAM ELEC page indicating that the load is
abnormal.
•GALLEY FAULT light illuminated on the
ELEC panel helping you to locate the switch.
(The galley will be switched off to reduce the
load.)

ELECTRICAL MENU Abnormal operation (A) 41/54


Notice
Notice that
that there
there is
is no
no FAULT
FAULT light
light in
in the
the GEN
GEN 22
pb
pb sw
sw because
because thethe generator
generator is
is still
still powering
powering the
the
AC bus 2.
AC bus 2.

ELECTRICAL MENU Abnormal operation (A) 42/54


The PF will ask you to perform the ECAM
actions.

Perform ECAM action.

ELECTRICAL MENU Abnormal operation (A) 43/54


The PF will ask you to perform the ECAM
actions.

No, press the GALLEY pb sw.

ELECTRICAL MENU Abnormal operation (A) 44/54


The PF will ask you to perform the ECAM
actions.

No, press the GALLEY pb sw.

ELECTRICAL MENU Abnormal operation (A) 45/54


You can see, on the ECAM ELEC page:

•GALLEY SHED indication has appeared


•GEN 2 load is back to a normal value.

ELECTRICAL MENU Abnormal operation (A) 46/54


After review and confirmation from the PF...

Clear ELEC.

ELECTRICAL MENU Abnormal operation (A) 47/54


After review and confirmation from the PF...

No, press either CLR key.

ELECTRICAL MENU Abnormal operation (A) 48/54


After review and confirmation from the PF...

No, press either CLR key.

ELECTRICAL MENU Abnormal operation (A) 49/54


The STATUS page is displayed for review.

You can see that the galley is inoperative.

ELECTRICAL MENU Abnormal operation (A) 50/54


After review and confirmation from the PF…

Clear STATUS.

ELECTRICAL MENU Abnormal operation (A) 51/54


After review and confirmation from the PF…

No, press the STS key or either CLR key.

ELECTRICAL MENU Abnormal operation (A) 52/54


After review and confirmation from the PF…

No, press the STS key or either CLR key.

ELECTRICAL MENU Abnormal operation (A) 53/54


ECAM action completed.

Module completed
ELECTRICAL MENU Abnormal operation (A) 54/54 NEXT
LIST
LIST OF
OF SUBJECTS
SUBJECTS
IDG OIL LOW PRESSURE FAULT
GEN 2 OVERLOAD

AUDIO GLOSSARY FCOM

RETURN EXIT

ELECTRICAL MENU Abnormal operation (A) 55/54