CURRENT ISSUES AND
RECOMMENDATION ON
MAINTENANCE AND
OPERATION MANAGEMENT
1. Short of Manpower/Technician
2. Water Pump not Work Properly
3. Retrofitting
4. Don’t Have Proper Data for Maintenance
Schedule
ISSUES
01.
Figure 2.3.1
Find young labour because they can handle the heavy operation work such as the building
technician or mechanical operation work.
SWOT ANALYSIS
Strength Weakness
• can handle the heavy operation work such Inexperienced employees to handle the
as the building technician or mechanical operation and maintenance at Wisma
operation work. FGV
Opportunity Threat
Water pump unable to supply water to the some of upper level Wisma FGV faced insufficient fluorescent lamp in their
and caused inconvenience to the user in building building
Several issues can appear due to the water pump failure such Every fluorescent lamp should have two working bulb per set
as cavitation, fluid stagnation , leakage and pump damage.
Based on site visit, some of the lamp has missing lamp and
some of the fluorescent not even light up.
03.
04.
ISSUES
Wisma FGV don’t have a proper data in their maintenance schedule for their building
Even though Wisma FGV has the maintenance schedule, but the maintenance department not regularly
update the schedule
This will cause misunderstanding and miscommunication between technician in the department itself to
do the maintenance work for every system or services in the building.
RECOMMENDATION
Suggested to apply technology to Wisma FVG such as Computerize Maintenance Management System
(CMMS) to help maintenance department to overcome issues related to system or services.
Maintenance Connection Software that founded by Accruent Maintenance Software would be suitable
for maintenance department of Wisma FGV to use
Offers whole gamut of assets and maintenance management features to Wisma FGV and helps them to
manage the lifecycle of assets
SWOT ANALYSIS
Strength Weakness
Opportunity Threat
Discontinued the
building automation
01
system (BAS) for
maintenance activity
for some issues. The top of organization had to
02
delay the request for
upgrading a new technology
of the building, because
focusing in major replacement
and breakdown
SWOT
S W O T
Act as a major Building automation A qualified The operators are
investment and the systems offer enhanced service technician required to run the
system receive control of a building’s has a set of eyes equipment in manual
regular attention various systems, on the system mode when
and care including heating and regularly. communication failure in
cooling (HVAC), BAS until the controller
electrical, security and so comes back online or is
on. replaced.
RECOMMENDATIONS
Organizations need to
have properly functioning
FGV building should upgraded systems and equipment
of BAS
Starting by talking with
building existing system
The owner can assess Assisting the owner supplier to find out what
the vendor proposals and in generating an RFP options they offer
determine which offers that clearly outlines
the greatest overall the upgrading
solution. requirements, Required a retrofitting
process of an old building
Building Automation
System (BAS)
S W O T
Require the No possibility smoke,
crossing of a road fire, or debris that
Assembly point or movement will injure the person If fitting is being done
should not be very through trafficked during the evacuation on a hot or icy day it
near to the process areas. of the premises or may be appropriate to
equipment and very whilst at the assembly have an alternative fire
far off for a person point. assembly point due to
to go to the the potential for injuries
assembly point. or health complications.
RECOMMENDATIONS
General fire
The path to the assembly point precautions that Due to the scale or complexity of the
must meet a number of needs to be taken in premises, prevailing weather conditions,
conditions like unobstructed at each specific area or hazardous materials location, occupants
all times, adequately marked, department of the requiring to leave from opposite sides of
and well lit building. a building, or people needing to exit
from opposite sides of a structure
Sekolah Kebangsaan Jalan Batu (P)
270m
The distance of FGV building to Sekolah Kebangsaan
Jalan Batu (P)
The picture of
surrounding at
Parking Raja Laut
03. LEGAL ISSUES FOR DISABLED (BUILDING RELATED TO THE ACT
01
Building Entrance for Disable (PWD)/Ramp Toilet for Disabled (PWD)
There are no disabled facilities (PWD) ramps at the main Does not have toilets for the disabled (PWD
entrance to the building.
Did not meet the criteria for planning the needs of the disabled
Make difficult for the disabled (PWD) to enter Wisma FGV. facilities (PWD) set out in the Malaysian Standard MS
1184:2014.
Non-compliant with MS1184: 2014. (Clause 6.1, page 23)
02
RECOMMENDATION
Ramps must be provided for any changes in the height of the route surface. Stairs Toilet size should not be smaller than 1600 mm X 2000 mm. It must have enough space for
should be provided adjacent to the ramp if the difference exceeds 300mm wheelchair to maneuver inside.
The slope of the ramp is not more than 1:12 ratio Toilet sign must be clearly visible. Only internationally adopted symbol should be used
The net width of the ramp shall be provided of not less than 1200mm. for ramps The doors should be either of the sliding or outward-opening type.
having handrails the minimum distance between handrails is 1000m
Floor should not be slippery.
End landing and intermediate landing distances shall be provided not less than
1500mm. For existing buildings, the length of the ramp without obstructions shall
There must be knee space clearance under the basins.
be provided not less than 1200mm
Mirrors must be big enough so that it is usable by people who sit on wheelchair
Handrails shall be provided on each ramp route exceeding 800mm in length
Door locks and taps should not be of the types that require pinching, tight grasping and fine
Drainage gratings on ramp routes should be flush in with the surface
finger control.
The ramp surface must be stable and not slippery whether in dry or wet
Doors should be of the type that can be opened from outside in case of emergency.
Layout and fixtures must be standardized so that people with visual impairment can find the
paper, sink and place to flush the toilet.
SWOT ANALYSIS
Complies with the Provide comfort to people Affect the landscape on the Many space/building
specifications set out in with disabilities (PWD) building due to the addition elements/structure need to
Malaysian Standard MS: while on/entering Wisma of structures that did not be repaired/altered and
1184: 2014 for facilities for FGV exist in the original design require high costs
the disabled (PWD)
CURRENT ISSUES AND
RECOMMENDATION ON FINANCIAL
MAINTENANCE MANAGEMENT
01. FINANCIAL
ISSUES RECOMMENDATION
BUDGET MANANGEMENT REALLOCATE BUDGET
Wisma FGV in term of managing the budget that has Suggest that financial department of Wisma FGV to allocate
been provided by the company extra budgeting for air conditioning system in the building in
term of maintaining and repairing the air conditioning
The budget for maintain air conditioning system for that
year is RM 126,388.00
Computerized Maintenance Management RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM 5,300.00 RM RM RM RM
5 10%
System & Building Automation System 63,600.00 69,960.00 76,956.00 84,651.60
RM RM RM RM
6 Utilities RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 RM146,318.42 10%
1,755,821.04 1,931,403.14 2,124,543.46 2,336,997.80
RM RM RM RM
7 Building Maintenance & Repair RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 RM 6,681.67 10%
80,180.04 88,198.04 97,017.85 106,719.63
RM RM RM RM
8 Fire Safety System RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 RM 1,676.11 10%
20,113.32 22,124.65 24,337.12 26,770.83
RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM
SUBTOTAL
207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 207,421.07 2,489,052.84 2,737,958.12 3,011,753.94 3,312,929.33
RM RM RM RM
TOTAL
5,194,706.05 5,714,176.66 6,285,594.32 6,914,153.75
CURRENT ISSUES AND
RECOMMENDATION ON
BUILDING CONDITION
ASSESSMENT
01. EXTERNAL CURTAIN WALL
ISSUES RECOMMENDATION
External wall very dirty (glaze curtain wall) Provide Gondola Cleaning System
Wisma FGV has provided the gondola which located at the Reapply or reuse the external cleaning system for their building
roof top
Previously Wisma FGV stopped the usage of the gondola system due
The cleanliness work for external wall will be doing for every 5 to the maintenance and cost of operation
years
Help to prevent or detect any defect or failure that happen at the
external wall of the building.
The cleanliness of the wall is unsatisfactory and appropriate
action needs to be taken
Range price RM 9000
Unfortunately, Wisma FGV shut down the gondola because of
broken and not enough budgets for doing maintained
SWOT ANALYSIS
Easy to conduct the Increase the aesthetic Use extra cost for Produce hazard and
system for cleaning value of building maintaining and risk situation during
process operating operation
Improve skills for
Make the cleaning technical team to Unable to operate Possibility to
process become easy operate the system during bad weather breakdown during
operation is high
02. BUILDING DEFECTS
ISSUES RECOMMENDATION
Several major defects has been detected and all of the defect Treat the Building Defects
did not do the repairing work for a long time
UFM FACILITIES MANAGEMENT SDN BHD should treat
Type of defects that have been found in the building are water the defects in the building
stagnant at the basement floor, dampness at the basement floor,
holes at the ceiling, flaking of paints at the wall finishes and Some defects need to be priorities as it may affected other
missing ceiling. components and worse enough to ruin other services in the
building
All of these defects can become worst and will increase the
quantity of defects at the building in future UFM FACILITIES MANAGEMENT SDN BHD may apply
additional money from Wisma FGV to repair, replace and
maintain the services in the building
SWOT ANALYSIS
Extend the lifespan of Increase the Spend extra money for Defect repetition
the building performance of the inspection and maybe occur in future
building repairing work
Prevent the defect Untreated defect due
become worst Increase the safety of Misidentify the cause to false remedial
the occupant of defect works
EXAMPLE
Item Description Unit Quantity Unit Price Total (RM)
(RM)
Missing gypsum board ceiling
(Refer Defect No.5)
1. Place the new ceiling at the
missing area.
a) Labour cost
1 skilled labour
(1 hr x RM100.00/8hrs) No. 1 12.50
b) Material cost
Gypsum ceiling
(RM20.00/(1pcs x 1) mm 1 20.00 32.50
Wastage 5% 1.02 33.52
2. 15% Profit & overhead 5.03
TOTAL RM 38.55
BUILDING CONDITION ASSESSMENT
Overall Building Rating Analysis of Building Defects
Baris
No Element Defect Description Condition Priority Matrix No of Defect by Type
Assessment Assessment Analysis Defect
20% 20%
TOTAL MARKS 51
TOTAL DEFECTS 5
Recommendation that we provide can be use for Wisma FGV to overcome the issues that we mentioned
before.
Maintenance department should be more organized, better planning and monitor to keep and extend the
lifespan of the building and their systems.
Some of the issues can easily counter or overcome but some need to take further investigation or
inspection to identify the cause and ways to overcome the issues found .