FUNCTIONAL PLANNING

OF ADMINISTRATIVE
BUILDING
AN EDUCATIONAL
PRESENTATION BY
NAME PRN.NO
SWAPNIL KADAM 18UCE025
ADARSH POTDAR 19UCE316
CONTENT
 SITE SELECTION
 ORIENTATION
 ENTERY AREA
 SERVER ROOM
 ADMINISTRATIVE OFFICE
 ACCOUNT SECTION
 MEETING ROOM
 CONFERENCE ROOM
 STAFF ROOM
 PARKING
 WATCHMAN ROOM
C
O
Site selection
The directions and alignment of the plot with respect to
north, determines the location of spaces within the
structure, with respect to orientation principles. The most
suitable site is selected considering access to site,
characters of structures around the site, existing greenery,
and dimensions of the site so as to get an idea of
foreground and side margins, openness from point of view
of ventilation, light and view, sound and air pollution,
elevation of the ground with respect to the existing roads.
A suitable site is selected with size 78 m X 42 m with
access from its South. The rear side of the plot is open with
provision for enough ventilation and lighting.
Orientation
The building is proposed to be approximately in
rectangular form with the longitudinal axis of the building
aligned along the East-West direction where minimum heat
is received thus achieving temperature moderation and
natural day-lighting. This provision causes minimum
wall area to expose to direct sunrays and thus cause less
absorption and radiation of heat as well as avoid glare. The
exposure of south walls to the sun is reduced by providing
chhajjas and sun breakers.
The cabins of the account section are towards the North
to make use of the comfort zone with no direct sunrays and
air conditioned rooms are placed towards the south.
ENTERY AREA
DAIMENSION IS 3mX2.1m
FUNCTION:-TO ENTER IN BUILDING.IT IS THE
THRESHOLD BETWEEN THE EXTERIOR AND
INTERIOR.
`
`
`
SERVER ROOM

A server room is a room, usually air- conditioned,


devoted to the continuous operation of
computer servers. An entire building or station
devoted to this purpose is a data center. ...
Power Server rooms typically consume significant
power and may be designed to have redundant power
sources such as grid and solar power. The minimum
size of server room is 4mx3.5m.
Administrative office
Administrative office is of 100 square meter area with 9
cabins, reception and waiting area. Circulation space and
waiting area together consumes 54 square meter area.
Entrance to the section is of 1.5m wide. Store and staff
dining is provided adjacent to the office.
Cabins in the administrative office section are of size
260 cm X 220 cm. It includes working table of 160 cm
long and 80 cm wide and a small shelf of 50 cm width can
also be fitted into the space behind the table to give a
functionally designed cabin. Cabin provides a total
circulation space of 1.56 square meters, furniture space of
2.25 square meters and activity space of 1.91 square
meters. Panels around the cabin are of 160cm height.
Account section
Account section is of 11mx8.4m size which includes 4
cabins, treasures room, staff dining and waiting area.
Working space of 180cmx 220cm includes a table of 60cm
width Treasurer’s room is of 300cmx475cm
dimension.
Meeting rooms
An enclosed room equipped with appropriate
information and communication technology. Board room is
provided to hold meetings of the committees. The principal
furniture in the board room is a large rectangular table with
14 chairs around it, enclosed in an area of 450cmx840cm.
The table width is 2.0 m satisfying a minimum of 1.85m, to
allow members on both the sides with their papers. It
allows a 75cm space for persons.
Conference room
Conference room of size 850cmx840cm is laid out. It
is always better that rear wall does not follow the line of
curvature of the last seating row. The floor of auditorium is
made rising towards the rear. The back to back spacing
between two rows is 100cm.Passages along the width of
the room is having minimum width of 1m. A minimum
width of 1.2m is provided in between the rows of the seats
and sidewall. Two access doors of width 1.5 m are
provided satisfying the minimum width. The artificial
means of ventilation with fans and exhausts are also
installed. For good sight and audibility, rows of seats are
curved in plan. Separate room is provided to serve as a
storage space.
STAFF ROOM
 DAIMENSION:-4mX3m
 FUNCTIONT:-TO BREAKOUT AREA,A LIBRARY TO
STORE IMPORTANT DOCUMENT, AND PLACE CONDUCT
MEETINGS.
PARKING
 MINIMUM DAIMENSIONS

4 WHEELER 20 NO’S 2.5mX5.0m


2 WHEELER 30 NO’S 1.2mX2.7m
WATCHMAN ROOM
 DAIMENSION:- 1.21mX2.74m
 FUNCTGION:- FOR SECURITY PURPOSE.
 COUNTER:- ONE IS FOR INSIDE AND ONE IS FOR OUTSIDE.
WASH ROOM
 DAIMENSION:- 2.1mX2.44m

DOOR 1NO’S 0.75mX2.1m


W.C 2NO’S 1.0mX1.2m
SINK 4NO’S 0.4mX0.5m
PLAN